https://static.igem.org/mediawiki/2015/d/d8/Logo_HOME.png https://static.igem.org/mediawiki/2015/a/a4/Logo_PROJECT.png https://static.igem.org/mediawiki/2015/archive/b/b9/20150720104417%21Logo_TEAM.png https://static.igem.org/mediawiki/2015/8/86/Logo_NOTE.png https://static.igem.org/mediawiki/2015/8/87/Logo_RESULT.png https://static.igem.org/mediawiki/2015/2/28/Logo_MORE.png



InterLab Study


Equipment

  • BioSHAKER TA-12R
  • use for shaking culture



  • Safire ART-NR:F129013
  • use for measurement of absorbance




Method of Measurement

      We constructed 5 plasmids [positive control, negative control, device1~3] by using BioBricks and then transformed to E. coli K-12 JM109. We checked them by colony direct PCR and plasmids sequence. We cultivated correct bacterias by shaking until OD660:0.5. Cultivated mediums were transferred to 96-well plate by 100mL. We read the absorbance.


      Setting of plate reader is following:




    Sequence data

    ・device 1 : J23101+ I13504



    ・device 2 : J23106+ I13504



    ・device 3 : J23117+ I13504



    These sequence datas are correct.


Result

  • Definition
  •   We expressed absorbance as relative value for positive control.
    This expression is following:


      Sample : Absorbance in sample
      NCav : Average of absorbance in negative control
      PCav : Average of absorbance in positive control






  • Value
  • Relative absorbance values for positive control are shown below.








    FIG1 Relative absorbance values
    20K : Device1 (J23101 + I13504)
    22A : Device2 (J23106 + I13504)
    22K : Device3 (J23117 + I13504)




Discussion

      The value of device1 is much higher than that of device2 and 3. This is why each device is different from promoter sequence, especially -10 and -35 region.



    Promoter sequence in device1 resembles consensus sequence. On the other hand, device2 and 3 is not similar than device1. This is how each GFP expression is different.