Difference between revisions of "Team:DTU-Denmark/Project/Chip"

 
Line 3: Line 3:
 
     <meta name="viewport" content="width=device-width, initial-scale=1, maximum-scale=1, user-scalable=no">
 
     <meta name="viewport" content="width=device-width, initial-scale=1, maximum-scale=1, user-scalable=no">
 
     <meta http-equiv="X-UA-Compatible" content="IE=edge">
 
     <meta http-equiv="X-UA-Compatible" content="IE=edge">
   
 
   
 
    <link href="/Team:DTU-Denmark/loadphpcss?action=raw&ctype=text/css" rel="stylesheet">
 
    <link href="/Team:DTU-Denmark/bootstrapcss?action=raw&ctype=text/css" rel="stylesheet">
 
    <link href="/Team:DTU-Denmark/font-awesomecss?action=raw&ctype=text/css" rel="stylesheet">
 
    <link href="/Team:DTU-Denmark/wikicss?action=raw&ctype=text/css" rel="stylesheet">
 
    <link href="/Team:DTU-Denmark/timelinecss?action=raw&ctype=text/css" rel="stylesheet">
 
    <link href="/Team:DTU-Denmark/menufixcss?action=raw&ctype=text/css" rel="stylesheet">
 
  
   
+
      <link rel=stylesheet href="/Team:DTU-Denmark/loadphpcss?action=raw&ctype=text/css">
 +
      <link rel=stylesheet href="/Team:DTU-Denmark/bootstrapcss?action=raw&ctype=text/css">
 +
      <link rel=stylesheet href="/Team:DTU-Denmark/font-awesomecss?action=raw&ctype=text/css">
 +
      <link rel=stylesheet href="/Team:DTU-Denmark/wikicss?action=raw&ctype=text/css">
 +
      <link rel=stylesheet href="/Team:DTU-Denmark/timelinecss?action=raw&ctype=text/css">
 +
      <link rel=stylesheet href="/Team:DTU-Denmark/menufixcss?action=raw&ctype=text/css">
 +
 
 
     <script type="text/javascript" src="/Team:DTU-Denmark/jqueryjs?action=raw&ctype=text/javascript"></script>
 
     <script type="text/javascript" src="/Team:DTU-Denmark/jqueryjs?action=raw&ctype=text/javascript"></script>
 
     <script type="text/javascript" src="/Team:DTU-Denmark/bootstrapjs?action=raw&ctype=text/javascript"></script>
 
     <script type="text/javascript" src="/Team:DTU-Denmark/bootstrapjs?action=raw&ctype=text/javascript"></script>
 
     <script type="text/javascript" src="/Team:DTU-Denmark/jqueryeasingjs?action=raw&ctype=text/javascript"></script>
 
     <script type="text/javascript" src="/Team:DTU-Denmark/jqueryeasingjs?action=raw&ctype=text/javascript"></script>
 
     <script type="text/javascript" src="/Team:DTU-Denmark/wikijs?action=raw&ctype=text/javascript"></script>
 
     <script type="text/javascript" src="/Team:DTU-Denmark/wikijs?action=raw&ctype=text/javascript"></script>
 +
 
     <!-- MathJax (LaTeX for the web) -->
 
     <!-- MathJax (LaTeX for the web) -->
 
     <script src="https://2015.igem.org/common/MathJax-2.5-latest/MathJax.js?config=TeX-AMS-MML_SVG"></script>
 
     <script src="https://2015.igem.org/common/MathJax-2.5-latest/MathJax.js?config=TeX-AMS-MML_SVG"></script>
    <!-- HTML5 shim and Respond.js for IE8 support of HTML5 elements and media queries -->
 
    <!-- WARNING: Respond.js doesn't work if you view the page via file:// -->
 
    <!--[if lt IE 9]>
 
      <script src="https://oss.maxcdn.com/html5shiv/3.7.2/html5shiv.min.js"></script>
 
      <script src="https://oss.maxcdn.com/respond/1.4.2/respond.min.js"></script>
 
    <![endif]-->
 
 
      
 
      
 
   </head>
 
   </head>
Line 44: Line 37:
 
             <i class="fa fa-bars"></i>
 
             <i class="fa fa-bars"></i>
 
           </button>
 
           </button>
           <a class="navbar-brand navimg" href="#"><img src="/wiki/images/b/b7/DTU-Denmark_dtulogo.png"></a>
+
           <a class="navbar-brand navimg" href="#"><img src="https://static.igem.org/mediawiki/2015/b/b7/DTU-Denmark_dtulogo.png"></a>
 
         </div>
 
         </div>
 
         <!-- Collect the nav links, forms, and other content for toggling -->
 
         <!-- Collect the nav links, forms, and other content for toggling -->
 
         <div class="collapse navbar-collapse" id="nav-collapse">
 
         <div class="collapse navbar-collapse" id="nav-collapse">
 
           <ul class="nav navbar-nav">
 
           <ul class="nav navbar-nav">
<li >
+
                <li >
<a href="/Team:DTU-Denmark"
+
                <a href="/Team:DTU-Denmark"
  >Home
+
                  >Home
                                          </a></li>
+
                  </a></li>
<li  
+
                <li  
+
               
 
                      
 
                      
                 
+
               
 
                      
 
                      
                 
+
               
  >
+
                >
<a href=""
+
                <a href=""
  class="dropdown-toggle"
+
                  class="dropdown-toggle"
  data-toggle="dropdown"
+
                  data-toggle="dropdown"
  role="button"
+
                  role="button"
  aria-expanded="false">Team and Attributions
+
                  aria-expanded="false">Team and Attributions
                                          <span class="caret"></span></a><ul class="dropdown-menu" role="menu">
+
                  <span class="caret"></span></a><ul class="dropdown-menu" role="menu">
<li >
+
                <li >
<a href="/Team:DTU-Denmark/Team"
+
                <a href="/Team:DTU-Denmark/Team"
  >Team
+
                  >Team
                                          </a></li>
+
                  </a></li>
<li >
+
                <li >
<a href="/Team:DTU-Denmark/Attributions"
+
                <a href="/Team:DTU-Denmark/Attributions"
  >Attributions
+
                  >Attributions
                                          </a></li></ul></li>
+
                  </a></li></ul></li>
<li  
+
                <li  
+
               
 
                      
 
                      
                 
+
               
 
                      
 
                      
                 
+
               
 
                      
 
                      
                 
+
               
 
                      
 
                      
                 
+
               
                   
+
                 
+
 
                      
 
                      
 
                       class="active"
 
                       class="active"
 
                      
 
                      
                 
+
               
 
                      
 
                      
                 
+
               
 
                      
 
                      
                 
+
               
 +
                >
 +
                <a href=""
 +
                  class="dropdown-toggle"
 +
                  data-toggle="dropdown"
 +
                  role="button"
 +
                  aria-expanded="false">Project
 +
                  <span class="caret"></span></a><ul class="dropdown-menu" role="menu">
 +
                <li >
 +
                <a href="/Team:DTU-Denmark/Project/Overview"
 +
                  >Overview
 +
                  </a></li>
 +
                <li >
 +
                <a href="/Team:DTU-Denmark/Project/Background"
 +
                  >Background
 +
                  </a></li>
 +
                <li >
 +
                <a href="/Team:DTU-Denmark/Project/MAGE"
 +
                  >MAGE subtilis
 +
                  </a></li>
 +
                <li >
 +
                <a href="/Team:DTU-Denmark/Project/Tyrocidine"
 +
                  >Tyrocidine
 +
                  </a></li>
 +
                <li class="active">
 +
                <a href="/Team:DTU-Denmark/Project/Chip"
 +
                  >Lab-on-a-disc
 +
                  </a></li>
 +
                <li >
 +
                <a href="/Team:DTU-Denmark/Project/Inteins"
 +
                  >Inteins
 +
                  </a></li>
 +
                <li >
 +
                <a href="/Team:DTU-Denmark/Project/Detection"
 +
                  >Detection of NRP
 +
                  </a></li></ul></li>
 +
                <li >
 +
                <a href="/Team:DTU-Denmark/Practices"
 +
                  >Human Practices
 +
                  </a></li>
 +
                <li
 +
               
 
                      
 
                      
                 
+
               
  >
+
<a href=""
+
  class="dropdown-toggle"
+
  data-toggle="dropdown"
+
  role="button"
+
  aria-expanded="false">Project
+
                                          <span class="caret"></span></a><ul class="dropdown-menu" role="menu">
+
<li >
+
<a href="/Team:DTU-Denmark/Project/Overview"
+
  >Overview
+
                                          </a></li>
+
<li >
+
<a href="/Team:DTU-Denmark/Project/Background"
+
  >Background
+
                                          </a></li>
+
<li >
+
<a href="/Team:DTU-Denmark/Project/MAGE"
+
  >MAGE Subtilis
+
                                          </a></li>
+
<li >
+
<a href="/Team:DTU-Denmark/Project/Surfactin"
+
  >Surfactin
+
                                          </a></li>
+
<li >
+
<a href="/Team:DTU-Denmark/Project/Tyrocidine"
+
  >Tyrocidine
+
                                          </a></li>
+
<li class="active">
+
<a href="/Team:DTU-Denmark/Project/Chip"
+
  >Lab-on-a-disc
+
                                          </a></li>
+
<li >
+
<a href="/Team:DTU-Denmark/Project/Intein"
+
  >Inteins
+
                                          </a></li>
+
<li >
+
<a href="/Team:DTU-Denmark/Project/Detection"
+
  >Detection of NRP
+
                                          </a></li>
+
<li >
+
<a href="/Team:DTU-Denmark/Project/POC_MAGE"
+
  >Proof of concept of MAGE in B. subtilis
+
                                          </a></li></ul></li>
+
<li >
+
<a href="/Team:DTU-Denmark/Practices"
+
  >Human Practices
+
                                          </a></li>
+
<li
+
+
 
                      
 
                      
                 
+
               
 +
                >
 +
                <a href=""
 +
                  class="dropdown-toggle"
 +
                  data-toggle="dropdown"
 +
                  role="button"
 +
                  aria-expanded="false">Parts Collection
 +
                  <span class="caret"></span></a><ul class="dropdown-menu" role="menu">
 +
                <li >
 +
                <a href="/Team:DTU-Denmark/Parts"
 +
                  >Parts
 +
                  </a></li>
 +
                <li >
 +
                <a href="/Team:DTU-Denmark/Description"
 +
                  >Characterisation of xylR
 +
                  </a></li></ul></li>
 +
                <li >
 +
                <a href="/Team:DTU-Denmark/Journal"
 +
                  >Journal
 +
                  </a></li>
 +
                <li >
 +
                <a href="/Team:DTU-Denmark/Software"
 +
                  >Software
 +
                  </a></li>
 +
                <li
 +
               
 
                      
 
                      
                 
+
               
  >
+
<a href=""
+
  class="dropdown-toggle"
+
  data-toggle="dropdown"
+
  role="button"
+
  aria-expanded="false">Parts Collection
+
                                          <span class="caret"></span></a><ul class="dropdown-menu" role="menu">
+
<li >
+
<a href="/Team:DTU-Denmark/Parts"
+
  >Parts
+
                                          </a></li>
+
<li >
+
<a href="/Team:DTU-Denmark/Description"
+
  >Characterization of xylR
+
                                          </a></li></ul></li>
+
<li >
+
<a href="/Team:DTU-Denmark/Journal"
+
  >Journal
+
                                          </a></li>
+
<li >
+
<a href="/Team:DTU-Denmark/Software"
+
  >Software
+
                                          </a></li>
+
<li
+
+
 
                      
 
                      
                 
+
               
 
                      
 
                      
                 
+
               
                   
+
                >
                 
+
                <a href=""
  >
+
                  class="dropdown-toggle"
<a href=""
+
                  data-toggle="dropdown"
  class="dropdown-toggle"
+
                  role="button"
  data-toggle="dropdown"
+
                  aria-expanded="false">Achievements
  role="button"
+
                  <span class="caret"></span></a><ul class="dropdown-menu" role="menu">
  aria-expanded="false">Achievements
+
                <li >
                                          <span class="caret"></span></a><ul class="dropdown-menu" role="menu">
+
                <a href="/Team:DTU-Denmark/Achievements"
<li >
+
                  >Key Achievements
<a href="/Team:DTU-Denmark/Achievements"
+
                  </a></li>
  >Key Achievements
+
                <li >
                                          </a></li>
+
                <a href="/Team:DTU-Denmark/Collaborations"
<li >
+
                  >Collaborations
<a href="/Team:DTU-Denmark/Collaborations"
+
                  </a></li>
  >Collaborations
+
                <li >
                                          </a></li>
+
                <a href="/Team:DTU-Denmark/Judging_Form"
<li >
+
                  >Judging Form
<a href="/Team:DTU-Denmark/Judging%20Form"
+
                  </a></li></ul></li>
  >Judging Form
+
                                          </a></li></ul></li>
+
 
             <li class="hidden-xs">
 
             <li class="hidden-xs">
 
               <a href="http://facebook.com/dtubiobuilders" data-toggle="tooltip" data-placement="bottom" title="Follow us on Facebook">
 
               <a href="http://facebook.com/dtubiobuilders" data-toggle="tooltip" data-placement="bottom" title="Follow us on Facebook">
Line 213: Line 194:
 
             <li class="hidden-lg">
 
             <li class="hidden-lg">
 
               <a href="https://igem.org" target="_blank" class="navimg">
 
               <a href="https://igem.org" target="_blank" class="navimg">
                 <img src="/wiki/images/a/af/DTU-Denmark_igemlogo.png">
+
                 <img src="https://static.igem.org/mediawiki/2015/a/af/DTU-Denmark_igemlogo.png">
 
               </a>
 
               </a>
 
             </li>
 
             </li>
Line 220: Line 201:
 
       </div>
 
       </div>
 
     </nav>
 
     </nav>
    <nav class="navbar navbar-default extrabar hidden-xs hidden" data-spy="affix">
+
 
      <div class="container-fluid" id="scrollspy">
+
 
        <ul class="nav navbar-nav">
+
<nav class="navbar navbar-default extrabar hidden-xs hidden" data-spy="affix">
          <li><a class="page-scroll" href="#Lab-on-a-disc-Screening">Lab-on-a-disc Screening</a></li><li><a class="page-scroll" href="#Achievements">Achievements</a></li><li><a class="page-scroll" href="#Background">Background</a></li><li><a class="page-scroll" href="#Methods">Methods</a></li><li><a class="page-scroll" href="#Results">Results</a></li><li><a class="page-scroll" href="#Discussion">Discussion</a></li><li><a class="page-scroll" href="#Concept-of-lab-on-a-disc">Concept of lab-on-a-disc</a></li><li><a class="page-scroll" href="#References">References</a></li>
+
  <div class="container-fluid" id="scrollspy">
        </ul>
+
    <ul class="nav navbar-nav">
      </div>
+
      <li><a class="page-scroll" href="#Lab-on-a-discScreening">Lab-on-a-disc Screening</a></li><li><a class="page-scroll" href="#Achievements">Achievements</a></li><li><a class="page-scroll" href="#Background">Background</a></li><li><a class="page-scroll" href="#Methods">Methods</a></li><li><a class="page-scroll" href="#Results">Results</a></li><li><a class="page-scroll" href="#Discussion">Discussion</a></li><li><a class="page-scroll" href="#Conceptoflab-on-a-disc">Concept of lab-on-a-disc</a></li><li><a class="page-scroll" href="#References">References</a></li>
    </nav>
+
    </ul>
    <div class="jumbotron hero bg-hero">
+
  </div>
 +
</nav>
 +
 
 +
 
 +
<div class="jumbotron hero" style="background-image: url(https://static.igem.org/mediawiki/2015/0/0b/DTU-Denmark_hero.jpg)">
 
       <div class="igem-logo visible-lg">
 
       <div class="igem-logo visible-lg">
 
         <a href="https://igem.org" target="_blank">
 
         <a href="https://igem.org" target="_blank">
           <img src="/wiki/images/a/af/DTU-Denmark_igemlogo.png">
+
           <img src="https://static.igem.org/mediawiki/2015/a/af/DTU-Denmark_igemlogo.png">
 
         </a>
 
         </a>
 
       </div>
 
       </div>
Line 237: Line 222:
 
           <div class="col-md-12">
 
           <div class="col-md-12">
 
              
 
              
            <h3><br></h3>
+
<h3><br></h3>
            <h1>Lab-on-a-disc</h1>
+
<h1>Lab-on-a-disc</h1>
           
+
 
 
             <hr/>
 
             <hr/>
 +
           
 +
           
 
             <ul class="list-inline hidden-xs hidden-sm">
 
             <ul class="list-inline hidden-xs hidden-sm">
 
                
 
                
 
               <li>
 
               <li>
                 <a id="Lab-on-a-disc-Screening-submenu" class="btn btn-default btn-transparent btn-lg page-scroll" href="#Lab-on-a-disc-Screening">Lab-on-a-disc Screening</a>
+
                 <a id="Lab-on-a-discScreening-submenu" class="btn btn-default btn-transparent btn-lg page-scroll" href="#Lab-on-a-discScreening">Lab-on-a-disc Screening</a>
 
               </li>
 
               </li>
 
                
 
                
Line 268: Line 255:
 
                
 
                
 
               <li>
 
               <li>
                 <a id="Concept-of-lab-on-a-disc-submenu" class="btn btn-default btn-transparent btn-lg page-scroll" href="#Concept-of-lab-on-a-disc">Concept of lab-on-a-disc</a>
+
                 <a id="Conceptoflab-on-a-disc-submenu" class="btn btn-default btn-transparent btn-lg page-scroll" href="#Conceptoflab-on-a-disc">Concept of lab-on-a-disc</a>
 
               </li>
 
               </li>
 
                
 
                
Line 279: Line 266:
 
                
 
                
 
               <li>
 
               <li>
                 <a id="Lab-on-a-disc-Screening-submenu" class="page-scroll" href="#Lab-on-a-disc-Screening">Lab-on-a-disc Screening</a>
+
                 <a id="Lab-on-a-discScreening-submenu" class="page-scroll" href="#Lab-on-a-discScreening">Lab-on-a-disc Screening</a>
 
               </li>
 
               </li>
 
                
 
                
Line 303: Line 290:
 
                
 
                
 
               <li>
 
               <li>
                 <a id="Concept-of-lab-on-a-disc-submenu" class="page-scroll" href="#Concept-of-lab-on-a-disc">Concept of lab-on-a-disc</a>
+
                 <a id="Conceptoflab-on-a-disc-submenu" class="page-scroll" href="#Conceptoflab-on-a-disc">Concept of lab-on-a-disc</a>
 
               </li>
 
               </li>
 
                
 
                
Line 311: Line 298:
 
                
 
                
 
             </ul>
 
             </ul>
 +
           
 +
           
 
           </div>
 
           </div>
 
         </div>
 
         </div>
 +
       
 
         <div class="row">
 
         <div class="row">
 
           <div class="col-md-12">
 
           <div class="col-md-12">
 
             Scroll down for more<br>
 
             Scroll down for more<br>
             <a href="#Lab-on-a-disc-Screening" class="btn btn-circle btn-transparent page-scroll">
+
             <a href="#Lab-on-a-discScreening" class="btn btn-circle btn-transparent page-scroll">
 
               <i class="fa fa-angle-double-down"></i>
 
               <i class="fa fa-angle-double-down"></i>
 
             </a>
 
             </a>
 
           </div>
 
           </div>
 
         </div>
 
         </div>
 +
       
 
       </div>
 
       </div>
 
     </div>
 
     </div>
 
      
 
      
+
   
<div id="Lab-on-a-disc-Screening">
+
       
 +
<div id="Lab-on-a-discScreening">
 
   <div class="container">
 
   <div class="container">
 +
 
 
     <div class="row col-md-12">
 
     <div class="row col-md-12">
 
       <h1>
 
       <h1>
 
         Lab-on-a-disc Screening
 
         Lab-on-a-disc Screening
 
       </h1>
 
       </h1>
      <p>The results we have described so far have been focussing on developing libraries of nonribosomal peptides (NRP), but we have yet not described how these libraries may be screened. High throughput screening is essential to couple MAGE to improved drug design. In the laboratory, we have worked with tyrothricin, tyrocidine, and surfactins. They are all NRP antibiotics, which are cytotoxic to red blood cells [1][2][3]. In our first generation screening experiments, we tested if we could use this property to screen NRP libraries for reduced cytotoxicity.</p>
+
       
 +
        <p>The results we have described so far have focused&nbsp;on developing libraries of nonribosomal peptides (NRP), but we have not yet described how these libraries may be screened. High throughput screening is essential to couple MAGE to improved drug design. In the laboratory, we have worked with tyrocidine&nbsp;and surfactins. They are&nbsp;NRP antibiotics, which are cytotoxic to red blood cells [1][2][3]. In our first generation screening experiments, we tested if we could use this property to screen NRP libraries for reduced cytotoxicity.</p>
  
 +
       
 
     </div>
 
     </div>
 +
   
 
   </div>
 
   </div>
 
</div>
 
</div>
+
   
+
       
 
<div id="Achievements">
 
<div id="Achievements">
 
   <div class="container">
 
   <div class="container">
 +
 
 
     <div class="row col-md-12">
 
     <div class="row col-md-12">
 
       <h1>
 
       <h1>
 
         Achievements
 
         Achievements
 
       </h1>
 
       </h1>
      <ul>
+
       
<li>UV-vis absorbance spectra proved that red blood cells are lysed in presence of certain NRP. However, the experiments should be repeated with fresh blood cells.</li>
+
        <ul>
<li>Proof of concept on a lab-on-a-disc could be achieved.</li>
+
<li>UV-Vis&nbsp;absorbance spectra proved that red blood cells are lysed in the presence of certain NRPs. However, the experiments should be repeated with fresh blood cells. This means lab-on-disk experiments are feasible for screening mutated NRPs.</li>
 
</ul>
 
</ul>
  
 +
       
 
     </div>
 
     </div>
 +
   
 
   </div>
 
   </div>
 
</div>
 
</div>
+
   
+
       
 
<div id="Background">
 
<div id="Background">
 
   <div class="container">
 
   <div class="container">
 +
 
 
     <div class="row col-md-12">
 
     <div class="row col-md-12">
 
       <h1>
 
       <h1>
 
         Background
 
         Background
 
       </h1>
 
       </h1>
      <p style="text-align: justify;">Certain groups of nonribosomal peptides including commonly used antibiotics tyrothricin, tyrocidine, and surfactins, display non-specific cytotoxicity [1][2][3]. For this reason, these antibiotics are commonly used on external surfaces or topically as intravascular injection that causes hemolysis of red blood cells [1]. Low concentrations of NRP antibiotics have been fatal to animal model under some conditions which further&nbsp;supports the need for an <em>in-vitro</em> screening.&nbsp;UV-Vis absorbance spectrum depicts the amount of light absorbed by a measured solution or compounds included in a sample. The absorbance spectra of red blood cells from 300-800 nm changes depending on the state of the red blood cells. [4][5]</p>
+
       
 +
        <p style="text-align: justify;">Certain groups of nonribosomal peptides, including the commonly used antibiotic&nbsp;tyrocidine&nbsp;as well as surfactin, display non-specific cytotoxicity [1][2][3]. For this reason, these antibiotics are commonly used&nbsp;topically, as intravascular injection causes hemolysis of red blood cells [1]. Low concentrations of NRP antibiotics have been found to be fatal to animal models, which further&nbsp;supports the need for an <em>in-vitro</em> screening. Through UV-Vis spectrophotometry, we are able to&nbsp;analyze&nbsp;the amount of light absorbed in a solution with the addition of our compounds of interest. The absorbance spectra of red blood cells from 300-800 nm&nbsp;changes depending on the state of the red blood cells&nbsp;[4][5].</p>
  
 +
       
 
     </div>
 
     </div>
 +
   
 
   </div>
 
   </div>
 
</div>
 
</div>
+
   
+
       
 
<div id="Methods">
 
<div id="Methods">
 
   <div class="container">
 
   <div class="container">
 +
 
 
     <div class="row col-md-12">
 
     <div class="row col-md-12">
 
       <h1>
 
       <h1>
 
         Methods
 
         Methods
 
       </h1>
 
       </h1>
      <p style="text-align: justify;">To study cell lysis, the absorbance of fresh blood cells spiked&nbsp;with the addition of nonribosomal peptides was measured. UV-Vis absorption spectra was recorded between 300-800nm using three different divices: in cuvettes, by nanodrop, and&nbsp;on a&nbsp;DS-11 + Spectrophotometer (DeNovix). The concentration of NRP was varied between samples to determine cytotoxicity of tyrothricin and sensitivity of red blood cells.&nbsp;A detailed <a href="/wiki/images/6/62/DTU-Denmark_bloodcell_lysis.pdf" onclick="window.open(this.href, '', 'resizable=no,status=no,location=no,toolbar=no,menubar=no,fullscreen=no,scrollbars=no,dependent=no'); return false;">description</a> of the experiments can be found under&nbsp;<a href="/Team:DTU-Denmark/Journal">Lab NoteBook</a>.</p>
+
       
 +
        <p style="text-align: justify;">To study cell lysis, the absorbance of fresh blood cells was measured without NRP products in comparison to fresh blood spiked&nbsp;with tyrocidine. UV-Vis absorption spectra were recorded between 300-800 nm using three different devices;&nbsp;in cuvettes, by nanodrop, and&nbsp;on a&nbsp;DS-11 + Spectrophotometer (DeNovix). The concentration of NRP was varied between samples to determine cytotoxicity of tyrocidine&nbsp;and sensitivity of red blood cells.&nbsp;A detailed <a href="https://static.igem.org/mediawiki/2015/6/62/DTU-Denmark_bloodcell_lysis.pdf" onclick="window.open(this.href, '', 'resizable=no,status=no,location=no,toolbar=no,menubar=no,fullscreen=no,scrollbars=no,dependent=no'); return false;">description</a> of the experiments can be found under&nbsp;<a href="/Team:DTU-Denmark/Journal">Lab NoteBook</a>.</p>
  
 +
       
 
     </div>
 
     </div>
 +
   
 
   </div>
 
   </div>
 
</div>
 
</div>
+
   
+
       
 
<div id="Results">
 
<div id="Results">
 
   <div class="container">
 
   <div class="container">
 +
 
 
     <div class="row col-md-12">
 
     <div class="row col-md-12">
 
       <h1>
 
       <h1>
 
         Results
 
         Results
 
       </h1>
 
       </h1>
      <p style="text-align: justify;">The UV-Vis absorption spectra of red blood cells suspended in the absence or presence of antibiotic (Figure 1) proves toxicity of tyrothrycin towards blood cells. The drop of the green curve around 600nm indicates that red blood cells absorbs less at this wavelength. When the curve reaches 0, &nbsp;it is an indentication of&nbsp;cell lysis.<br />
+
       
 +
        <p style="text-align: justify;">The UV-Vis absorption spectra of red blood cells suspended in the absence or presence of antibiotic (Figure 1) proves toxicity of tyrocidine towards blood cells. For our test the antibiotic used was Tyrothricin, which is composed of 5 different tyrocidine varieties and gramacidin produced by <i>Brevibacillus parabrevis</i>.&nbsp;The drop of the green curve around 600 nm indicates that red blood cells absorbs less at this wavelength. When the curve reaches 0, &nbsp;it is an indication of&nbsp;cell lysis.<br />
 
&nbsp;</p>
 
&nbsp;</p>
  
<p style="text-align: center;"><img alt="" src="/wiki/images/d/da/DTU-Denmark_Lab_graph_1.jpg" style="width: 350px; height: 217px;" /></p>
+
<p style="text-align: center;"><img alt="" src="/files/Lab%20graph%201.jpg" style="width: 350px; height: 217px;" /></p>
  
 
<p align="center"><span style="font-size:14px;">Figure 1. Comparison of blood cells in different buffers.</span><br />
 
<p align="center"><span style="font-size:14px;">Figure 1. Comparison of blood cells in different buffers.</span><br />
Line 397: Line 406:
 
<p style="text-align: justify;">Decrease of UV absorbance around 600nm occurred in all of the blood samples with tyrothricin indicating lysis of the sample (Figure 2).</p>
 
<p style="text-align: justify;">Decrease of UV absorbance around 600nm occurred in all of the blood samples with tyrothricin indicating lysis of the sample (Figure 2).</p>
  
<p style="text-align: center;"><img alt="" src="/wiki/images/b/ba/DTU-Denmark_disc_exp1_tyr.jpg" style="width: 350px; height: 238px;" /></p>
+
<p style="text-align: center;"><img alt="" src="/files/disc%20exp1%20tyr.jpg" style="width: 350px; height: 238px;" /></p>
  
 
<p align="center"><span style="font-size:14px;">Figure 2. Comparison of blood cells in presence of antibiotics over time. &nbsp;</span><span style="font-size:12px;"><br />
 
<p align="center"><span style="font-size:14px;">Figure 2. Comparison of blood cells in presence of antibiotics over time. &nbsp;</span><span style="font-size:12px;"><br />
Line 404: Line 413:
 
<p style="text-align: justify;">Nanodrop measurements of red blood cells spiked with&nbsp;tyrothricin at different concentration:</p>
 
<p style="text-align: justify;">Nanodrop measurements of red blood cells spiked with&nbsp;tyrothricin at different concentration:</p>
  
<p style="text-align: center;"><img alt="" src="/wiki/images/d/df/DTU-Denmark_nanodrop.jpg" style="width: 550px; height: 255px;" /></p>
+
<p style="text-align: center;"><img alt="" src="https://static.igem.org/mediawiki/2015/d/df/DTU-Denmark_nanodrop.jpg" style="width: 550px; height: 255px;" /></p>
  
 
<p style="text-align: center;"><span style="font-size:14px;">Figure 3. Comparison of blood cells (anticoagulated with heparin) in presence of 0,15M NaCl and different concentrations of tyrothricin after 45-60sec of incubation. Nanodrop measurement.</span></p>
 
<p style="text-align: center;"><span style="font-size:14px;">Figure 3. Comparison of blood cells (anticoagulated with heparin) in presence of 0,15M NaCl and different concentrations of tyrothricin after 45-60sec of incubation. Nanodrop measurement.</span></p>
Line 412: Line 421:
 
<p style="text-align: justify;">It was also possible to test lysis of red blood cells using an extract from&nbsp;<em>Brevibacillus parabrevis </em>(Figure 4). Prescence of tyrocidine was confirmed by LC/MS and MALDI-TOF prior to the blood cell analysis. It is of interest to see, if cell extracts alone can be used to screen for cytotoxicity as it is easy to prepare cell extractions.</p>
 
<p style="text-align: justify;">It was also possible to test lysis of red blood cells using an extract from&nbsp;<em>Brevibacillus parabrevis </em>(Figure 4). Prescence of tyrocidine was confirmed by LC/MS and MALDI-TOF prior to the blood cell analysis. It is of interest to see, if cell extracts alone can be used to screen for cytotoxicity as it is easy to prepare cell extractions.</p>
  
<p style="text-align: center;"><img alt="" src="/wiki/images/3/36/DTU-Denmark_exp_3.jpg" style="width: 550px; height: 257px;" /></p>
+
<p style="text-align: center;"><img alt="" src="/files/exp%203.jpg" style="width: 550px; height: 257px;" /></p>
  
 
<p align="center"><span style="font-size:14px;">Figure 4. UV-vis absorption spectra of blood anticoagulated with heparin in presence of unknown concentrations of tyrocidine after 45-60sec of incubation. Nanodrop measurement.</span></p>
 
<p align="center"><span style="font-size:14px;">Figure 4. UV-vis absorption spectra of blood anticoagulated with heparin in presence of unknown concentrations of tyrocidine after 45-60sec of incubation. Nanodrop measurement.</span></p>
Line 418: Line 427:
 
<p style="text-align: justify;">In this experiment, cell lysis is also&nbsp;observed in all samples as with the standard. The control sample should retain blood cell stability, yet it did not. This may be due to the same factors as previously discussed.&nbsp;The data shows that further&nbsp;experiments are required to confirm cell lysis across samples. The high peaks of a few samples might suggest complete cell lysis is due to the presence of antibiotics.</p>
 
<p style="text-align: justify;">In this experiment, cell lysis is also&nbsp;observed in all samples as with the standard. The control sample should retain blood cell stability, yet it did not. This may be due to the same factors as previously discussed.&nbsp;The data shows that further&nbsp;experiments are required to confirm cell lysis across samples. The high peaks of a few samples might suggest complete cell lysis is due to the presence of antibiotics.</p>
  
 +
       
 
     </div>
 
     </div>
 +
   
 
   </div>
 
   </div>
 
</div>
 
</div>
+
   
+
       
 
<div id="Discussion">
 
<div id="Discussion">
 
   <div class="container">
 
   <div class="container">
 +
 
 
     <div class="row col-md-12">
 
     <div class="row col-md-12">
 
       <h1>
 
       <h1>
 
         Discussion
 
         Discussion
 
       </h1>
 
       </h1>
      <p style="text-align: justify;">The results indicates, despite their uncertainity, that screening of on blood samples can be used as method for screening. Litterature supports&nbsp;lab-on-a-disc screening as having strong&nbsp;potential to be a low-cost, quick, and simple way of detect&nbsp;and screening libraries of NRP antibiotics. For this reason, we have described the basis of a lab-on-disc device.</p>
+
       
 +
        <p style="text-align: justify;">The results indicates, despite their uncertainity, that screening of on blood samples can be used as method for screening. Litterature supports&nbsp;lab-on-a-disc screening as having strong&nbsp;potential to be a low-cost, quick, and simple way of detect&nbsp;and screening libraries of NRP antibiotics. For this reason, we have described the basis of a lab-on-disc device.</p>
  
 +
       
 
     </div>
 
     </div>
 +
   
 
   </div>
 
   </div>
 
</div>
 
</div>
+
   
+
       
<div id="Concept-of-lab-on-a-disc">
+
<div id="Conceptoflab-on-a-disc">
 
   <div class="container">
 
   <div class="container">
 +
 
 
     <div class="row col-md-12">
 
     <div class="row col-md-12">
 
       <h1>
 
       <h1>
 
         Concept of lab-on-a-disc
 
         Concept of lab-on-a-disc
 
       </h1>
 
       </h1>
      <p style="text-align: justify;">The rotating disc would be an easy and low-cost way to screen bacterial colonies. Our inspiration came from the start-up company BluSense Diagnostics, who specialise within microfluidics and rotor devices.&nbsp;The rotor disc would enable visual screening (detection) of bacterial colonies by mixing both small volumes of red blood cells and supernatants of bacterial culture.&nbsp;The primary idea of the disc would enable us to screen five different colonies at the same time. Figure 5., below, displays a simple set-up of lab-on-a-disc device.</p>
+
       
 +
        <p style="text-align: justify;">The rotating disc would be an easy and low-cost way to screen bacterial colonies. Our inspiration came from the start-up company BluSense Diagnostics, who specialise within microfluidics and rotor devices.&nbsp;The rotor disc would enable visual screening (detection) of bacterial colonies by mixing both small volumes of red blood cells and supernatants of bacterial culture.&nbsp;The primary idea of the disc would enable us to screen five different colonies at the same time. Figure 5., below, displays a simple set-up of lab-on-a-disc device.</p>
  
<p style="text-align: center;"><img alt="" src="/wiki/images/8/80/DTU-Denmark_labonadiscilustra.jpg" style="width: 350px; height: 239px;" /></p>
+
<p style="text-align: center;"><img alt="" src="https://static.igem.org/mediawiki/2015/8/80/DTU-Denmark_labonadiscilustra.jpg" style="width: 350px; height: 239px;" /></p>
  
 
<p align="center"><span style="font-size:14px;">Figure 5. Illustration of lab-on-a-chip concept for screening the MAGE products.</span></p>
 
<p align="center"><span style="font-size:14px;">Figure 5. Illustration of lab-on-a-chip concept for screening the MAGE products.</span></p>
Line 450: Line 467:
 
<p style="text-align: justify;">The use of the disc for observing cell lysis is very easy (Figure 5.). According to methods used in BluSense Diagnostics, it consists of a few steps. First, loading the bacterial supernatant and blood volume to specific inlets (Figure 6). When the disc starts to rotate, the bacterial supernatant is moved to the mixing/detection chamber&nbsp;where a&nbsp;certain&nbsp;volume of the blood sample is measured out and then moved (with the next rotation) to a mixing chamber, where it is mixed with bacterial supernatant&nbsp;(Figure 7.A). Subsequently, the disc stops rotating, before again beginning to accelerate and decelerate for a certain time period to mix the fluid (Figure&nbsp;7.B). The disc stops and after a certain time period, the blood cells can be analysed by UV-Vis as described earlier to determine, if the sample contains cytotoxic&nbsp;antibiotics.</p>
 
<p style="text-align: justify;">The use of the disc for observing cell lysis is very easy (Figure 5.). According to methods used in BluSense Diagnostics, it consists of a few steps. First, loading the bacterial supernatant and blood volume to specific inlets (Figure 6). When the disc starts to rotate, the bacterial supernatant is moved to the mixing/detection chamber&nbsp;where a&nbsp;certain&nbsp;volume of the blood sample is measured out and then moved (with the next rotation) to a mixing chamber, where it is mixed with bacterial supernatant&nbsp;(Figure 7.A). Subsequently, the disc stops rotating, before again beginning to accelerate and decelerate for a certain time period to mix the fluid (Figure&nbsp;7.B). The disc stops and after a certain time period, the blood cells can be analysed by UV-Vis as described earlier to determine, if the sample contains cytotoxic&nbsp;antibiotics.</p>
  
<p align="center"><img alt="" src="/wiki/images/5/5e/DTU-Denmark_lab_on_a_disc_.jpg" style="width: 350px; height: 400px;" /></p>
+
<p align="center"><img alt="" src="/files/lab%20on%20a%20disc%20.jpg" style="width: 350px; height: 400px;" /></p>
  
 
<p align="center"><span style="font-size:14px;">Figure 6. &nbsp;Visual presentation of an original disc design. Disc provided by BluSense Diagnostics.</span></p>
 
<p align="center"><span style="font-size:14px;">Figure 6. &nbsp;Visual presentation of an original disc design. Disc provided by BluSense Diagnostics.</span></p>
  
<p align="center"><img alt="" src="/wiki/images/c/c0/DTU-Denmark_mixing_steps.jpg" style="width: 550px; height: 258px;" /></p>
+
<p align="center"><img alt="" src="/files/mixing%20steps.jpg" style="width: 550px; height: 258px;" /></p>
  
 
<p align="center"><span style="font-size:14px;">Figure 7. &nbsp;Visualisation of rotations influencing &nbsp;samples&rsquo; microflow. </span><span style="font-size:14px;"></span><br />
 
<p align="center"><span style="font-size:14px;">Figure 7. &nbsp;Visualisation of rotations influencing &nbsp;samples&rsquo; microflow. </span><span style="font-size:14px;"></span><br />
Line 464: Line 481:
 
<p>&nbsp;</p>
 
<p>&nbsp;</p>
  
 +
       
 
     </div>
 
     </div>
 +
   
 
   </div>
 
   </div>
 
</div>
 
</div>
+
   
+
       
 
<div id="References">
 
<div id="References">
 
   <div class="container">
 
   <div class="container">
 +
 
 
     <div class="row col-md-12">
 
     <div class="row col-md-12">
 
       <h1>
 
       <h1>
 
         References
 
         References
 
       </h1>
 
       </h1>
      <ol>
 
 
          
 
          
          <li>Dubos, R. J. (1941). THE PRODUCTION OF BACTERICIDAL SUBSTANCES BY AEROBIC SPORULATING BACILLI. Journal of Experimental Medicine, 73(5), 629–640. <a href="http://dx.doi.org/10.1084/jem.73.5.629" target="_blank">doi:10.1084/jem.73.5.629</a></li>
+
<ol>
       
+
   
          <li>  Findlay R. D., Taeusch H. W., David-Cu R., Walther F. J., Pediatr Res., Lysis of red blood cells and alveolar epithelial toxicity by therapeutic pulmonary surfactants.(1995); 37(1):26-30.</li>
+
  <li>Dubos, R. J. (1941). THE PRODUCTION OF BACTERICIDAL SUBSTANCES BY AEROBIC SPORULATING BACILLI. Journal of Experimental Medicine, 73(5), 629–640. <a href="http://dx.doi.org/10.1084/jem.73.5.629" target="_blank">doi:10.1084/jem.73.5.629</a></li>
       
+
   
          <li>Pape W. J., Pfannenbecker U., Hoppe U. (1987-1988 Fall) Validation of the red blood cell test system as in vitro assay for the rapid screening of irritation potential of surfactants.Mol Toxicol.;1(4):525-36</li>
+
  <li>  Findlay R. D., Taeusch H. W., David-Cu R., Walther F. J., Pediatr Res., Lysis of red blood cells and alveolar epithelial toxicity by therapeutic pulmonary surfactants.(1995); 37(1):26-30.</li>
       
+
   
          <li>Jiang, N., Tan, N. S., Ho, B., & Ding, J. L. (2007). Measurement of the red blood cell lysis by bacterial hemolysin. Protocol Exchange. <a href="http://dx.doi.org/10.1038/nprot.2007.483" target="_blank">doi:10.1038/nprot.2007.483</a></li>
+
  <li>Pape W. J., Pfannenbecker U., Hoppe U. (1987-1988 Fall) Validation of the red blood cell test system as in vitro assay for the rapid screening of irritation potential of surfactants.Mol Toxicol.;1(4):525-36</li>
       
+
   
          <li> Jávorfi T., Erostyák J., Gál J., Buzády A., Menczel L., Garab G., Razi Naqvi K. J. Photochem Photobiol B. (2006) Quantitative spectrophotometry using integrating cavities. 82(2):127-31. Epub 2005 Nov</li>
+
  <li>Jiang, N., Tan, N. S., Ho, B., & Ding, J. L. (2007). Measurement of the red blood cell lysis by bacterial hemolysin. Protocol Exchange. <a href="http://dx.doi.org/10.1038/nprot.2007.483" target="_blank">doi:10.1038/nprot.2007.483</a></li>
       
+
   
      </ol>
+
  <li> Jávorfi T., Erostyák J., Gál J., Buzády A., Menczel L., Garab G., Razi Naqvi K. J. Photochem Photobiol B. (2006) Quantitative spectrophotometry using integrating cavities. 82(2):127-31. Epub 2005 Nov</li>
 +
   
 +
</ol>
 +
 
 
     </div>
 
     </div>
 +
   
 
   </div>
 
   </div>
 
</div>
 
</div>
+
   
     <div class="container">
+
      
 +
<footer class="container">
 
       <div class="row">
 
       <div class="row">
 
         <div class="col-md-2 col-md-offset-2">
 
         <div class="col-md-2 col-md-offset-2">
 
           <a href="http://www.dtu.dk" target="_blank">
 
           <a href="http://www.dtu.dk" target="_blank">
             <img src="/wiki/images/b/b7/DTU-Denmark_dtulogo.png" height="130px">
+
             <img src="https://static.igem.org/mediawiki/2015/b/b7/DTU-Denmark_dtulogo.png" height="130px">
 
           </a>
 
           </a>
 
         </div>
 
         </div>
Line 512: Line 536:
 
         <div class="col-md-2">
 
         <div class="col-md-2">
 
           <a href="https://igem.org" style="float:left" target="_blank">
 
           <a href="https://igem.org" style="float:left" target="_blank">
               <img src="/wiki/images/a/af/DTU-Denmark_igemlogo.png" height="90px">
+
               <img src="https://static.igem.org/mediawiki/2015/a/af/DTU-Denmark_igemlogo.png" height="90px">
 
           </a>
 
           </a>
 
         </div>
 
         </div>
 
       </div>
 
       </div>
     </div>
+
     </footer>
 
     <div class="sponsors">
 
     <div class="sponsors">
       <div class="container-fluid">
+
       <div class="container">
 
         <div class="row">
 
         <div class="row">
 
            
 
            
 
           <div class="sponsorlogo">
 
           <div class="sponsorlogo">
 
             <a href="http://www.lundbeckfonden.com/" target="_blank">
 
             <a href="http://www.lundbeckfonden.com/" target="_blank">
               <img src="/wiki/images/e/e2/DTU-Denmark_Lundbeckfonden.jpg">
+
               <img src="https://static.igem.org/mediawiki/2015/e/e2/DTU-Denmark_Lundbeckfonden.jpg">
 
             </a>
 
             </a>
 
           </div>
 
           </div>
Line 529: Line 553:
 
           <div class="sponsorlogo">
 
           <div class="sponsorlogo">
 
             <a href="http://www.ottomoensted.dk" target="_blank">
 
             <a href="http://www.ottomoensted.dk" target="_blank">
               <img src="/wiki/images/3/35/DTU-Denmark_Ottomoensted.png">
+
               <img src="https://static.igem.org/mediawiki/2015/3/35/DTU-Denmark_Ottomoensted.png">
 
             </a>
 
             </a>
 
           </div>
 
           </div>
Line 535: Line 559:
 
           <div class="sponsorlogo">
 
           <div class="sponsorlogo">
 
             <a href="http://www.novonordiskfonden.dk/en" target="_blank">
 
             <a href="http://www.novonordiskfonden.dk/en" target="_blank">
               <img src="/wiki/images/5/5c/DTU-Denmark_NovoNordiskFonden_logo.png">
+
               <img src="https://static.igem.org/mediawiki/2015/5/5c/DTU-Denmark_NovoNordiskFonden_logo.png">
 
             </a>
 
             </a>
 
           </div>
 
           </div>
Line 541: Line 565:
 
           <div class="sponsorlogo">
 
           <div class="sponsorlogo">
 
             <a href="https://dk.vwr.com/" target="_blank">
 
             <a href="https://dk.vwr.com/" target="_blank">
               <img src="/wiki/images/e/ea/DTU-Denmark_VWR.jpg">
+
               <img src="https://static.igem.org/mediawiki/2015/e/ea/DTU-Denmark_VWR.jpg">
 
             </a>
 
             </a>
 
           </div>
 
           </div>
Line 547: Line 571:
 
           <div class="sponsorlogo">
 
           <div class="sponsorlogo">
 
             <a href="http://frisenette.dk" target="_blank">
 
             <a href="http://frisenette.dk" target="_blank">
               <img src="/wiki/images/c/c8/DTU-Denmark_Frisenette.jpg">
+
               <img src="https://static.igem.org/mediawiki/2015/c/c8/DTU-Denmark_Frisenette.jpg">
 
             </a>
 
             </a>
 
           </div>
 
           </div>
Line 553: Line 577:
 
           <div class="sponsorlogo">
 
           <div class="sponsorlogo">
 
             <a href="http://www.in-vitro.dk/" target="_blank">
 
             <a href="http://www.in-vitro.dk/" target="_blank">
               <img src="/wiki/images/7/7c/DTU-Denmark_In_Vitro.jpg">
+
               <img src="https://static.igem.org/mediawiki/2015/7/7c/DTU-Denmark_In_Vitro.jpg">
 
             </a>
 
             </a>
 
           </div>
 
           </div>
Line 559: Line 583:
 
           <div class="sponsorlogo">
 
           <div class="sponsorlogo">
 
             <a href="https://dk.fishersci.com/dk/" target="_blank">
 
             <a href="https://dk.fishersci.com/dk/" target="_blank">
               <img src="/wiki/images/b/b4/DTU-Denmark_Fisher_Scientific.jpg">
+
               <img src="https://static.igem.org/mediawiki/2015/b/b4/DTU-Denmark_Fisher_Scientific.jpg">
 
             </a>
 
             </a>
 
           </div>
 
           </div>
Line 565: Line 589:
 
           <div class="sponsorlogo">
 
           <div class="sponsorlogo">
 
             <a href="http://us.akg.com/akg-homepage-us.html" target="_blank">
 
             <a href="http://us.akg.com/akg-homepage-us.html" target="_blank">
               <img src="/wiki/images/9/9d/DTU-Denmark_AKG.png">
+
               <img src="https://static.igem.org/mediawiki/2015/9/9d/DTU-Denmark_AKG.png">
 
             </a>
 
             </a>
 
           </div>
 
           </div>
Line 571: Line 595:
 
           <div class="sponsorlogo">
 
           <div class="sponsorlogo">
 
             <a href="http://www.macrogen.com/" target="_blank">
 
             <a href="http://www.macrogen.com/" target="_blank">
               <img src="/wiki/images/1/11/DTU-Denmark_Marcogen.jpg">
+
               <img src="https://static.igem.org/mediawiki/2015/1/11/DTU-Denmark_Marcogen.jpg">
 
             </a>
 
             </a>
 
           </div>
 
           </div>
Line 577: Line 601:
 
           <div class="sponsorlogo">
 
           <div class="sponsorlogo">
 
             <a href="http://www.snapgene.com/" target="_blank">
 
             <a href="http://www.snapgene.com/" target="_blank">
               <img src="/wiki/images/5/58/DTU-Denmark_Snapgene.png">
+
               <img src="https://static.igem.org/mediawiki/2015/5/58/DTU-Denmark_Snapgene.png">
 
             </a>
 
             </a>
 
           </div>
 
           </div>
Line 583: Line 607:
 
           <div class="sponsorlogo">
 
           <div class="sponsorlogo">
 
             <a href="https://www.neb.com/" target="_blank">
 
             <a href="https://www.neb.com/" target="_blank">
               <img src="/wiki/images/e/e0/DTU-Denmark_NEB_logo.png">
+
               <img src="https://static.igem.org/mediawiki/2015/e/e0/DTU-Denmark_NEB_logo.png">
 
             </a>
 
             </a>
 
           </div>
 
           </div>

Latest revision as of 15:15, 9 November 2015

Lab-on-a-disc Screening

The results we have described so far have focused on developing libraries of nonribosomal peptides (NRP), but we have not yet described how these libraries may be screened. High throughput screening is essential to couple MAGE to improved drug design. In the laboratory, we have worked with tyrocidine and surfactins. They are NRP antibiotics, which are cytotoxic to red blood cells [1][2][3]. In our first generation screening experiments, we tested if we could use this property to screen NRP libraries for reduced cytotoxicity.

Achievements

  • UV-Vis absorbance spectra proved that red blood cells are lysed in the presence of certain NRPs. However, the experiments should be repeated with fresh blood cells. This means lab-on-disk experiments are feasible for screening mutated NRPs.

Background

Certain groups of nonribosomal peptides, including the commonly used antibiotic tyrocidine as well as surfactin, display non-specific cytotoxicity [1][2][3]. For this reason, these antibiotics are commonly used topically, as intravascular injection causes hemolysis of red blood cells [1]. Low concentrations of NRP antibiotics have been found to be fatal to animal models, which further supports the need for an in-vitro screening. Through UV-Vis spectrophotometry, we are able to analyze the amount of light absorbed in a solution with the addition of our compounds of interest. The absorbance spectra of red blood cells from 300-800 nm changes depending on the state of the red blood cells [4][5].

Methods

To study cell lysis, the absorbance of fresh blood cells was measured without NRP products in comparison to fresh blood spiked with tyrocidine. UV-Vis absorption spectra were recorded between 300-800 nm using three different devices; in cuvettes, by nanodrop, and on a DS-11 + Spectrophotometer (DeNovix). The concentration of NRP was varied between samples to determine cytotoxicity of tyrocidine and sensitivity of red blood cells. A detailed description of the experiments can be found under Lab NoteBook.

Results

The UV-Vis absorption spectra of red blood cells suspended in the absence or presence of antibiotic (Figure 1) proves toxicity of tyrocidine towards blood cells. For our test the antibiotic used was Tyrothricin, which is composed of 5 different tyrocidine varieties and gramacidin produced by Brevibacillus parabrevis. The drop of the green curve around 600 nm indicates that red blood cells absorbs less at this wavelength. When the curve reaches 0,  it is an indication of cell lysis.
 

Figure 1. Comparison of blood cells in different buffers.
grey line: blood cells anticoagulated in heparin with 0.15M NaCl; non-lysed
green line: blood cells anticoagulated in heparin with unknown concentration of Tyrothrycin; lysed

Decrease of UV absorbance around 600nm occurred in all of the blood samples with tyrothricin indicating lysis of the sample (Figure 2).

Figure 2. Comparison of blood cells in presence of antibiotics over time.  
pink and black line : unknown concentration of Tyrothrycin measured after 30sec with blood cells anticoagulated in heparin; green line: unknown concentration of Tyrothrycin measured after 120sec with blood cells anticoagulated in heparin.

Nanodrop measurements of red blood cells spiked with tyrothricin at different concentration:

Figure 3. Comparison of blood cells (anticoagulated with heparin) in presence of 0,15M NaCl and different concentrations of tyrothricin after 45-60sec of incubation. Nanodrop measurement.

In all samples, incomplete cell lysis was observed (Figure 3). The lysis may be incomplete due to the shorten incubation time of 45-60 seconds. The blood sample resuspended in 0.15M NaCl also shows turbidity at 600-700nm, despite it being an isotonic solution. The partly cell lysis may be explained by either the pipette tip bursting the cells (mechanical forces) or due to hemolysis of the cells. The blood cells were at the point tested three days old, which may lead to bursting[5]. We can conclude that the antibiotic lyses the red blood cells, but we cannot determine its specificity very accurately.

It was also possible to test lysis of red blood cells using an extract from Brevibacillus parabrevis (Figure 4). Prescence of tyrocidine was confirmed by LC/MS and MALDI-TOF prior to the blood cell analysis. It is of interest to see, if cell extracts alone can be used to screen for cytotoxicity as it is easy to prepare cell extractions.

Figure 4. UV-vis absorption spectra of blood anticoagulated with heparin in presence of unknown concentrations of tyrocidine after 45-60sec of incubation. Nanodrop measurement.

In this experiment, cell lysis is also observed in all samples as with the standard. The control sample should retain blood cell stability, yet it did not. This may be due to the same factors as previously discussed. The data shows that further experiments are required to confirm cell lysis across samples. The high peaks of a few samples might suggest complete cell lysis is due to the presence of antibiotics.

Discussion

The results indicates, despite their uncertainity, that screening of on blood samples can be used as method for screening. Litterature supports lab-on-a-disc screening as having strong potential to be a low-cost, quick, and simple way of detect and screening libraries of NRP antibiotics. For this reason, we have described the basis of a lab-on-disc device.

Concept of lab-on-a-disc

The rotating disc would be an easy and low-cost way to screen bacterial colonies. Our inspiration came from the start-up company BluSense Diagnostics, who specialise within microfluidics and rotor devices. The rotor disc would enable visual screening (detection) of bacterial colonies by mixing both small volumes of red blood cells and supernatants of bacterial culture. The primary idea of the disc would enable us to screen five different colonies at the same time. Figure 5., below, displays a simple set-up of lab-on-a-disc device.

Figure 5. Illustration of lab-on-a-chip concept for screening the MAGE products.

The use of the disc for observing cell lysis is very easy (Figure 5.). According to methods used in BluSense Diagnostics, it consists of a few steps. First, loading the bacterial supernatant and blood volume to specific inlets (Figure 6). When the disc starts to rotate, the bacterial supernatant is moved to the mixing/detection chamber where a certain volume of the blood sample is measured out and then moved (with the next rotation) to a mixing chamber, where it is mixed with bacterial supernatant (Figure 7.A). Subsequently, the disc stops rotating, before again beginning to accelerate and decelerate for a certain time period to mix the fluid (Figure 7.B). The disc stops and after a certain time period, the blood cells can be analysed by UV-Vis as described earlier to determine, if the sample contains cytotoxic antibiotics.

Figure 6.  Visual presentation of an original disc design. Disc provided by BluSense Diagnostics.

Figure 7.  Visualisation of rotations influencing  samples’ microflow.
A)Two different solutions are transferred to the mixing chamber. B) Mixture after several rotations of the disc. C) Visible cell lysis. 
Pictures provided by BluSense Diagnostics.

Further investigation is still required to determine: sensitivity the test, the interaction between bacterial supernatant-red blood cells, the most efficient method of extraction of NRPs for screening, and optimization parameters for mixing and microflow within the disc. However, it is very likely that this design would be an applicable screening method for MAGE. 

 

References

  1. Dubos, R. J. (1941). THE PRODUCTION OF BACTERICIDAL SUBSTANCES BY AEROBIC SPORULATING BACILLI. Journal of Experimental Medicine, 73(5), 629–640. doi:10.1084/jem.73.5.629
  2. Findlay R. D., Taeusch H. W., David-Cu R., Walther F. J., Pediatr Res., Lysis of red blood cells and alveolar epithelial toxicity by therapeutic pulmonary surfactants.(1995); 37(1):26-30.
  3. Pape W. J., Pfannenbecker U., Hoppe U. (1987-1988 Fall) Validation of the red blood cell test system as in vitro assay for the rapid screening of irritation potential of surfactants.Mol Toxicol.;1(4):525-36
  4. Jiang, N., Tan, N. S., Ho, B., & Ding, J. L. (2007). Measurement of the red blood cell lysis by bacterial hemolysin. Protocol Exchange. doi:10.1038/nprot.2007.483
  5. Jávorfi T., Erostyák J., Gál J., Buzády A., Menczel L., Garab G., Razi Naqvi K. J. Photochem Photobiol B. (2006) Quantitative spectrophotometry using integrating cavities. 82(2):127-31. Epub 2005 Nov
Technical University of Denmark
Department of Systems Biology
Søltofts Plads 221
2800 Kgs. Lyngby
Denmark
P: +45 45 25 25 25
M: dtu-igem-2015@googlegroups.com