     <p style="font-color:blue;font-size:18px"><b>Separating Gel</b></p>
+
     <p style="font color=blue;font-size:18px"><b>Separating Gel</b></p>
 
     <p>1) Level glass plates in the casting frame and place the frame within the casting stand.Ensure the plates are locked into place.<br>2) Place the following solutions in a 50ml falcon tube:<br></p>
 
     <p>1) Level glass plates in the casting frame and place the frame within the casting stand.Ensure the plates are locked into place.<br>2) Place the following solutions in a 50ml falcon tube:<br></p>
  
Line 447: Line 447:
  
 
                 <br>
 
                 <br>
     <p style="font-size:16px"><b><u>Electrophoresis</u></b><br></p>
+
     <p style="font-size:18px"><b>Electrophoresis</b><br></p>
  
 
<p> 1) Prepare samples that will be ran in the gel electrophoresis.<br> 2) Mix 15μl of each sample with 5μl of sample buffer solutiom. A 3 to 1 ratio is used. A maximum of 30μl can be inserted into each well.<br> 3) Place glass plates in the electrode assembly and into the tank cell.<br> 4) Fill tank with 1X electro buffer solution. Using a loading pipette and tips, load desired samples into wells along with a molecular weight ladder sample.<br> 5) Connect the lid to the tank and place the correct cables onto the tank lid. Run gel at 120 volts for 60-90 minutes or until desired bands are about the length of the gel.</p>
 
<p> 1) Prepare samples that will be ran in the gel electrophoresis.<br> 2) Mix 15μl of each sample with 5μl of sample buffer solutiom. A 3 to 1 ratio is used. A maximum of 30μl can be inserted into each well.<br> 3) Place glass plates in the electrode assembly and into the tank cell.<br> 4) Fill tank with 1X electro buffer solution. Using a loading pipette and tips, load desired samples into wells along with a molecular weight ladder sample.<br> 5) Connect the lid to the tank and place the correct cables onto the tank lid. Run gel at 120 volts for 60-90 minutes or until desired bands are about the length of the gel.</p>

Revision as of 22:29, 17 August 2015

Team NAIT 2015

Experimental Design

Go through our interactive experimental design flow chart! Many of our protocols are manufacturer specicfied; however, some are customized by us! PDFs of protocols can also be found

Theorizing our Sequences
Literature has shown certain proteins inherently stain in colour.
Looked up characteristics of said proteins
Isolated and identified the unique characteristics of said proteins so that we can manually write our own sequences and generate custom proteins.
Writing our Sequences
Went down to base pair level and wrote out our sequences with the defining characteristics identified in literature.
PCR
Digestion and Ligation
Transforming Bacteria
Validating the Transformation
Protein Isolation and Purification
SDS PAGE and Silver Staining