Difference between revisions of "Team:Leicester/Measurement"

Line 43: Line 43:
 
<h2> Results </h2>
 
<h2> Results </h2>
 
<img src="https://static.igem.org/mediawiki/2015/8/8a/LeicesterMicroplate_reader.jpg" align="right">
 
<img src="https://static.igem.org/mediawiki/2015/8/8a/LeicesterMicroplate_reader.jpg" align="right">
<p>Fluorescence results for the Interlab study were obtained using the BMG LABTECH FLUOstar Omega Microplate Reader. We placed all the replicates (technical and biological) on a black based 96 well plate.</p>
+
<p>Fluorescence results for the Interlab study were obtained using the BMG LABTECH FLUOstar Omega Microplate Reader. We placed all the replicates (technical and biological) on a black based 96 well plate. Results were obtained in the format of arbitrary fluorescence unit/OD 600</p>
 +
 
 
<p><i><b> Microplate Reader Settings</i></p></b>   
 
<p><i><b> Microplate Reader Settings</i></p></b>   
 
<ul>
 
<ul>
Line 49: Line 50:
 
<li> Excitation - 485-12nm</li>
 
<li> Excitation - 485-12nm</li>
 
<li>No. of flashes per well- 20</li>
 
<li>No. of flashes per well- 20</li>
 +
 +
<p> All results from each device were then placed in the format of graphs as such:
 +
  
 
<h2> Discussion and Difficulties </h2>
 
<h2> Discussion and Difficulties </h2>

Revision as of 16:59, 7 September 2015

Live Preview

Overview

As a team we decided that we would do some extra work during our time doing the iGEM project this such that we entered to take part in the Interlab Measurement study. The study requires us to look at the fluorescence of given gene circuits made up of parts found in the 2015 Distribution Kits.

The study requires producing 3 devices each consisting of a promoter sequence (depicted as different coloured arrows on Figure 1) and Green Fluorescence Protein (GFP) intermediate (I13504). Each of the devices are shown below:

  • Device 1 - J23101 + I13504

  • Device 2 - J23106 + I13504

  • Device 3 - J23117 + I13504



As part of the Interlab study, we then did extra credit where we had get biological and technical replicates of each device. They have been defined as such:

  • Biological Replicate -

  • Technical Replicate -

Methodology

In order to get the

Results

Fluorescence results for the Interlab study were obtained using the BMG LABTECH FLUOstar Omega Microplate Reader. We placed all the replicates (technical and biological) on a black based 96 well plate. Results were obtained in the format of arbitrary fluorescence unit/OD 600

Microplate Reader Settings

  • Emission - EMS20
  • Excitation - 485-12nm
  • No. of flashes per well- 20
  • All results from each device were then placed in the format of graphs as such:

    Discussion and Difficulties