Difference between revisions of "Team:Czech Republic/Microfluidics"
(→References) |
(→Signal transduction characterisation on-chip) |
||
Line 47: | Line 47: | ||
We developed a new fluorescence reporter assay system on-chip which allows dynamic detection of GPCR signaling in yeast using live fluorescence microscopy. First, fluorescent reporter proteins are connected to specific functional products signalling activation of the specific G protein–coupled receptor (GPCR). Details on the synthesis and function of reporter plasmids are provided by [[Team:Czech_Republic/Project/Signal_transduction|Module 1]]. Synthesised reporter plasmids were transformed to specific yeast strains to enable characterisation of yeast signalling using set of orthogonal signals designed and synthesised by [[Team:Czech_Republic/Project/Synthetic_signals_and_receptors |Module 2]]. | We developed a new fluorescence reporter assay system on-chip which allows dynamic detection of GPCR signaling in yeast using live fluorescence microscopy. First, fluorescent reporter proteins are connected to specific functional products signalling activation of the specific G protein–coupled receptor (GPCR). Details on the synthesis and function of reporter plasmids are provided by [[Team:Czech_Republic/Project/Signal_transduction|Module 1]]. Synthesised reporter plasmids were transformed to specific yeast strains to enable characterisation of yeast signalling using set of orthogonal signals designed and synthesised by [[Team:Czech_Republic/Project/Synthetic_signals_and_receptors |Module 2]]. | ||
− | [[File:GFP_Gradient_Static.jpg|Fluorescence microscopy image showing activation of MATa | + | [[File:GFP_Gradient_Static.jpg|Fluorescence microscopy image showing activation of MATa yeast pheromone pathway.]] |
Fabricated microfluidic devices were used to characterise the signal transduction between selected yeast strains. Two cell types are selected for each experiment. One cell type transmits the signal in the form of specific pheromone molecules. And the other cell type produces the Green Fluorescent Protein (GFP) when the signal is received if the pheromone molecules fit the specific receptor. Both cell types are introduced to the microfluidic device in parallel through separated inlets. Due to the laminar nature of the flow, the individual cell types remain spatially separated inside the microfluidic device. The spatial separation is well visible during the filling of the microfluidic device. The flow is stopped when the filling of the microfluidic device is finished, and the rest of the experiment is performed statically. Subsequently, time lapse fluorescence microscopy is used to dynamically measure levels of GFP expression in the cells that receive the signal. | Fabricated microfluidic devices were used to characterise the signal transduction between selected yeast strains. Two cell types are selected for each experiment. One cell type transmits the signal in the form of specific pheromone molecules. And the other cell type produces the Green Fluorescent Protein (GFP) when the signal is received if the pheromone molecules fit the specific receptor. Both cell types are introduced to the microfluidic device in parallel through separated inlets. Due to the laminar nature of the flow, the individual cell types remain spatially separated inside the microfluidic device. The spatial separation is well visible during the filling of the microfluidic device. The flow is stopped when the filling of the microfluidic device is finished, and the rest of the experiment is performed statically. Subsequently, time lapse fluorescence microscopy is used to dynamically measure levels of GFP expression in the cells that receive the signal. |
Revision as of 15:50, 17 September 2015
Microfluidics
Contents
Abstract
Microfluidic devices were designed and fabricated to characterise the signal transduction in the developed IOD band system. Signal transduction between transmitting and receiving cells was characterised using spatially separated cell cultures inside single microfluidic channel in conjunction with live fluorescence microscopy. Plasmids coding a synthetic reporter protein were transformed to signal receiving cells to show activation of its MAPK cascade. The on-chip characterisation was used to evaluate the signal transduction distance limit, its dynamic behavior, and reliability.
Key Achievements
- Set of microfluidic devices fabricated by PDMS soft-lithography.
- Characterisation of signal transduction distance limit between wildtype MATa and MATx Saccharomyces cerevisiae cells.
- Dynamic characterisation of signal transduction between synthetic MATa and MATx Saccharomyces cerevisiae cells.
Introduction
The diffusion processes are slow, and the inertial effects are negligible on micro-scale with low Reynolds number [Angelescu2011]. Hence microfluidics enables complex control of the cellular microenvironment. Microfluidic experiments in conjunction with live fluorescence microscopy were designed and performed to verify and characterise the the signal transduction mechanism in the developed IOD band system.
Soft-lithography
Microfluidic channels were formed using PDMS soft-lithography technology, which has proven biocompatibility and can be readily applied in available laminar flow cabinets [Fikar2015]. Photomask and silicon master fabrication was outsourced. Fabrication of microfluidic devices was divided in two subsequent steps. In the first step, silicon masters were used for the PDMS molding. In the second step, PDMS molds were bonded to the glass substrates to form encapsulated microfluidic devices using air plasma technology.
PDMS molding
Two part silicone elastomer Sylgard 184 was used to produce PDMS. The base part was mixed with sufficient amount of curing agent (10:1 ratio). The mixture was centrifuged to remove the air bubbles introduced by the mixing. The silicon master was placed in an aluminum foil container and the mixture was poured over. The remaining air bubbles were removed from the PDMS by sharp tip of a needle. The poured PDMS was maintained in perfect horizontal position to assure good planarity, and was cured in an oven, for 2 hours at 80°C. The PDMS edges were cut off with sharp tool and the PDMS was peeled off the silicon master. The PDMS mold was sliced into sections containing individual devices. Inlets and outlets were drilled carefully by biopsy punch of the appropriate diameter at the desired locations of the PDMS replica. Detailed experimental protocol is provided here.
Bonding of PDMS to the glass substrate
Prepared PDMS replicas with imprinted micro-structures were cleaned properly with scotch tape. The PDMS and glass substrate were treated by air plasma for 2.5 minutes. The air plasma affects the PDMS backbone and forms reactive silanol functional groups (Si-OH) enabling formation of permanent irreversible covalent bond of the PDMS to the glass substrate [Wong2009]. In addition, the PDMS treatment with air plasma is beneficial as it avoids nonspecific adsorption, decreases cell clogging and turns the PDMS to hydrophilic. The hydrophilicity of PDMS facilitates the future microchannel wetting [Kalio2006]. Immediately after the air plasma treatment, the glass substrate was brought into contact with the PDMS replica and placed in the oven, for 5 minutes at 80°C. The bonded devices were stored in a room temperature. Inlets and outlets were sealed with scotch tape to avoid contamination. Detailed experimental protocol is provided here.
Experimental setup
Microfluidic experiments were conducted on a platform already established by the Georgiev lab. The laboratory is equipped with precise microfluidic syringe system (neMESYS Low Pressure Syringe Pumps), and microscopic station enabling fluorescence imaging and live cell microscopy (Olympus IX83, CellSens software).
Microfluidic experiments
Signal transduction characterisation on-chip
We developed a new fluorescence reporter assay system on-chip which allows dynamic detection of GPCR signaling in yeast using live fluorescence microscopy. First, fluorescent reporter proteins are connected to specific functional products signalling activation of the specific G protein–coupled receptor (GPCR). Details on the synthesis and function of reporter plasmids are provided by Module 1. Synthesised reporter plasmids were transformed to specific yeast strains to enable characterisation of yeast signalling using set of orthogonal signals designed and synthesised by Module 2.
Fabricated microfluidic devices were used to characterise the signal transduction between selected yeast strains. Two cell types are selected for each experiment. One cell type transmits the signal in the form of specific pheromone molecules. And the other cell type produces the Green Fluorescent Protein (GFP) when the signal is received if the pheromone molecules fit the specific receptor. Both cell types are introduced to the microfluidic device in parallel through separated inlets. Due to the laminar nature of the flow, the individual cell types remain spatially separated inside the microfluidic device. The spatial separation is well visible during the filling of the microfluidic device. The flow is stopped when the filling of the microfluidic device is finished, and the rest of the experiment is performed statically. Subsequently, time lapse fluorescence microscopy is used to dynamically measure levels of GFP expression in the cells that receive the signal.
All experiments were conducted on Saccharomyces cerevisiae cells. Signal transduction was tested between the following types:
- POSITIVE CONTROL: Wildtype MATx ↝ MATa: STE2 receptor from Sacharomyces cerevisiae
- POSITIVE CONTROL: MATa expressing "Candida parapsilosis" alpha-factor; \(\Delta\)Bar ↝ MATa: STE2 receptor from Candida parapsilosis
- NEGATIVE CONTROL: MATa expressing "Candida parapsilosis" alpha-factor; \(\Delta\)Bar ↝ MATa: STE2 receptor from Sacharomyces cerevisiae
Results of the experiment show...
Personnel
- Martin Cienciala - Microfluidic experiments
- Vaclav Pelisek - Fabrication of microfluidic devices
- Pavel Fikar - Scientific advisor
References
- ↑ Dan E. Angelescu (2011). Highly Integrated Microfluidic Design. Artech House, Norwood.
- ↑ Ieong Wong (2009). Surface molecular property modifications for poly(dimethylsiloxane) (pdms) based microfluidic devices. Microfluid Nanofluid, 7:291–306.
- ↑ Johana Kuncova-Kallio (2006). Pdms and its suitability for analytical microfluidic devices. In Proceedings of the 28th IEEE EMBS Annual International Conference, New York City, USA, 9, IEEE.
- ↑ Sung Hwan Choi (2009). Microinjection molded disposable microfluidic lab-on-a-chip for efficient detection of agglutination. Microsystem Technologies, 15(2):309-316.
- ↑ P. Fikar (2015). SU8 microchannels for live cell dielectrophoresis improvements. In Proceedings of the Design, Test, Integration and Packaging of MEMS/MOEMS Symposium, Montpellier, FR.