− | <dd> | + | <dd>1. Prepare selective media (LB with 0.25% agar (2,5g/l) in Petri dishes (85 mm dia.).</dd> |
− | <dd> | + | <dd>2. Apply 1,5 µL of the diluted cell suspensions from mid-log-phase cultures (~2×105 cells/µL (OD=0,5)) to the center of the plates, and let them dry in air for 15 min </dd> |
+ | <dd>3. Incubate at 37 °C for 10 h. </dd> | ||
</dl> | </dl> | ||
Line 160: | Line 161: | ||
<dl> | <dl> | ||
<dt> Day 1:</dt> | <dt> Day 1:</dt> | ||
− | <dd>Strike your cells on a plate and grow overnight in 37°C.</dd> | + | <dd>1. Strike your cells on a plate and grow overnight in 37°C.</dd> |
<br/> | <br/> | ||
<dt>Day 2</dt> | <dt>Day 2</dt> | ||
− | <dd>Pick a single colony from your plate and grow it in 1-3 mL salt free LB overnight in 37°C.</dd> | + | <dd>2. Pick a single colony from your plate and grow it in 1-3 mL salt free LB overnight in 37°C.</dd> |
<dt>Day 3: </dt> | <dt>Day 3: </dt> | ||
<dd>1. Grow 300-400 mL cells (without salt) in 37°C untill the OD reaches 0.6 (use a starting culture).</dd> | <dd>1. Grow 300-400 mL cells (without salt) in 37°C untill the OD reaches 0.6 (use a starting culture).</dd> | ||
Line 189: | Line 190: | ||
<p><b>Protocols:</b></p> | <p><b>Protocols:</b></p> | ||
<dl> | <dl> | ||
− | <dd> | + | <dd>1. Add 1 µl DNA to 50 µl electrocompetent cells in an ice-cold cuvette (1 mm)</dd> |
− | <dd> | + | <dd>2. Electroporate (Eppendorf, 1700 V, 4 msec)</dd> |
− | <dd> | + | <dd>3. Add 950 µl of SOC solution</dd> |
− | <dd> | + | <dd>4. Incubate for one hour at 37 °C</dd> |
− | <dd> | + | <dd>5. Plate this out on pre-warmed plates (37 °C)</dd> |
<dl></p> | <dl></p> | ||
</div> | </div> | ||
Line 210: | Line 211: | ||
<p><b>Protocol :</b></p> | <p><b>Protocol :</b></p> | ||
<dl> | <dl> | ||
− | <dd> | + | <dd>1. Transfer the liquid cultures to an eppendorf tube and spin down a 13400 rpm for 1 à 2 minutes</dd> |
− | <dd>Resuspend the pelleted cels in 250 µL of the Resuspension solution. The cells should be resuspended completely by vortexing or pipetting up and down until no cell clumps remain.</dd> | + | <dd>2. Resuspend the pelleted cels in 250 µL of the Resuspension solution. The cells should be resuspended completely by vortexing or pipetting up and down until no cell clumps remain.</dd> |
− | <dd>Add 250 µL of the Lysis Solution and mix thoroughly by inverting the tube 4-6 times until the solution becomes viscous and slightly clear. | + | <dd>3. Add 250 µL of the Lysis Solution and mix thoroughly by inverting the tube 4-6 times until the solution becomes viscous and slightly clear. |
Note. Do not vortex to avoid shearing of chromosomal DNA. | Note. Do not vortex to avoid shearing of chromosomal DNA. | ||
Do not incubate for more than 5 min to avoid denaturation of supercoiled plasmid DNA </dd> | Do not incubate for more than 5 min to avoid denaturation of supercoiled plasmid DNA </dd> | ||
− | <dd>Add 350 µL of the Neutralization Solution and mix immediately and thoroughly by inverting the tube 4-6 times. | + | <dd>4. Add 350 µL of the Neutralization Solution and mix immediately and thoroughly by inverting the tube 4-6 times. |
Note. It is important to mix thoroughly and gently after the addition of the Neutralization Solution to avoid localized precipitation of bacterial cell debris. The neutralized bacterial lysate shoud become cloudy</dd> | Note. It is important to mix thoroughly and gently after the addition of the Neutralization Solution to avoid localized precipitation of bacterial cell debris. The neutralized bacterial lysate shoud become cloudy</dd> | ||
− | <dd>Centrifuge for 5 min to pellet cell debris and chromosomal DNA. </dd> | + | <dd>5. Centrifuge for 5 min to pellet cell debris and chromosomal DNA. </dd> |
− | <dd>Transfer the supernatant to the supplied GeneJET spin column by decanting or pipetting. Avoid disturbing or transferring the white precipitate. Note. Close the bag with GeneJET Spin Columns tightly after each use! </dd> | + | <dd>6. Transfer the supernatant to the supplied GeneJET spin column by decanting or pipetting. Avoid disturbing or transferring the white precipitate. Note. Close the bag with GeneJET Spin Columns tightly after each use! </dd> |
− | <dd>Centrifuge for 1 min. Discard the flow-through and place the column back into the same collection tube. </dd> | + | <dd>7. Centrifuge for 1 min. Discard the flow-through and place the column back into the same collection tube. </dd> |
− | <dd>Add 500 µL of the Wash Solution (diluted with ethanol prior to first use as described on p.3) to the GeneJET spin column. Centrifuge for 30-60 seconds and discard the flow-through. Place the column back into the same collection tube. </dd> | + | <dd>8. Add 500 µL of the Wash Solution (diluted with ethanol prior to first use as described on p.3) to the GeneJET spin column. Centrifuge for 30-60 seconds and discard the flow-through. Place the column back into the same collection tube. </dd> |
− | <dd>Repeat the wash procedure (step 8) using 500 µL of the Wash Solution. </dd> | + | <dd>9. Repeat the wash procedure (step 8) using 500 µL of the Wash Solution. </dd> |
− | <dd>Discard the flow-through and centrifuge for an additional 1 min to remove residual Wash Solution. This step is essential to avoid residual ethanol in plasmid preps.</dd> | + | <dd>10. Discard the flow-through and centrifuge for an additional 1 min to remove residual Wash Solution. This step is essential to avoid residual ethanol in plasmid preps.</dd> |
− | <dd>Transfer the GeneJET spin column into a fresh 1.5 mL microcentrifuge tube (not included). Add 50 µL of the Elution Buffer to the center of GeneJET spin column membrane to elute the plasmid DNA. Take care not to contact the membrane with the pipette tip. Incubate for 2 min at room temperature and centrifuge for 2 min. | + | <dd>11. Transfer the GeneJET spin column into a fresh 1.5 mL microcentrifuge tube (not included). Add 50 µL of the Elution Buffer to the center of GeneJET spin column membrane to elute the plasmid DNA. Take care not to contact the membrane with the pipette tip. Incubate for 2 min at room temperature and centrifuge for 2 min. |
Note. An additional elution step (optional) with Elution Buffer or water will recover residual DNA from the membrane and increase the overall yield by 10-20%. For elution of plasmids or cosmids >20 kb, prewarm Elution Buffer to 70°C before applying to silica membrane. </dd> | Note. An additional elution step (optional) with Elution Buffer or water will recover residual DNA from the membrane and increase the overall yield by 10-20%. For elution of plasmids or cosmids >20 kb, prewarm Elution Buffer to 70°C before applying to silica membrane. </dd> | ||
− | <dd> Discard the column and store the purified plasmid DNA at -20°C. </dd> | + | <dd>12. Discard the column and store the purified plasmid DNA at -20°C. </dd> |
</dl> | </dl> | ||
Line 244: | Line 245: | ||
<p><b>Protocol:</b></p> | <p><b>Protocol:</b></p> | ||
<dl> | <dl> | ||
− | <dd>1 | + | <dd>1. Add a 1:1 volume of Binding Buffer to completed PCR mixture (e.g. for every 100 µL of reaction mixture, add 100 µL of Binding Buffer). Mix thoroughly. Check the color of the solution. A yellow color indicates an optimal pH for DNA binding. If the color of the solution is orange or violet, add 10 µL of 3 M sodium acetate, pH 5.2 solution and mix. The color of the mix will become yellow.</dd> |
− | <dd> 2 | + | <dd> 2. Transfer up to 800 µL of the solution from step 1 (or optional step 2) to the GeneJET purification column. Centrifuge for 30-60 s. Discard the flow-through. Notes. If the total volume exceeds 800 µL, the solution can be added to the column in stages. After the addition of 800 µL of solution, centrifuge the column for 30-60 s and discard flowthrough. Repeat until the entire solution has been added to the column membrane. Close the bag with GeneJET Purification Columns tightly after each use! </dd> |
− | <dd>Add 700 µL of Wash Buffer (diluted with the ethanol as described on p. 3) to the GeneJET purification column. Centrifuge for 30-60 s. Discard the flow-through and place the purification column back into the collection tube.</dd> | + | <dd>3. Add 700 µL of Wash Buffer (diluted with the ethanol as described on p. 3) to the GeneJET purification column. Centrifuge for 30-60 s. Discard the flow-through and place the purification column back into the collection tube.</dd> |
<dd>Transfer the GeneJET purification column to a clean 1.5 mL microcentrifuge tube (not included). Add 50 µL of Elution Buffer to the center of the GeneJET purification column membrane and centrifuge for 1 min.</dd> | <dd>Transfer the GeneJET purification column to a clean 1.5 mL microcentrifuge tube (not included). Add 50 µL of Elution Buffer to the center of the GeneJET purification column membrane and centrifuge for 1 min.</dd> | ||
<p><b>Note.</b> | <p><b>Note.</b> | ||
For low DNA amounts the elution volumes can be reduced to increase DNA concentration. An elution volume between 20-50 µL does not significantly reduce the DNA yield. However, elution volumes less than 10 µL are not recommended. If DNA fragment is >10 kb, prewarm Elution Buffer to 65 °C before applying to column. If the elution volume is 10 µL and DNA amount is ≥5 µg, incubate column for 1 min at room temperature before centrifugation.<p></dd> | For low DNA amounts the elution volumes can be reduced to increase DNA concentration. An elution volume between 20-50 µL does not significantly reduce the DNA yield. However, elution volumes less than 10 µL are not recommended. If DNA fragment is >10 kb, prewarm Elution Buffer to 65 °C before applying to column. If the elution volume is 10 µL and DNA amount is ≥5 µg, incubate column for 1 min at room temperature before centrifugation.<p></dd> | ||
− | <dd>Discard the GeneJET purification column and store the purified DNA at -20 °C. </dd> | + | <dd>4. Discard the GeneJET purification column and store the purified DNA at -20 °C. </dd> |
<dl> | <dl> | ||
</div> | </div> | ||
Line 262: | Line 263: | ||
<p><b>Protocol : </b><p> | <p><b>Protocol : </b><p> | ||
<dl> | <dl> | ||
− | <dd>Excise the DNA fragment from the agarose gel with a clean, sharp scalpel. Minimize the size of the gel slice by removing extra agarose. </dd> | + | <dd>1. Excise the DNA fragment from the agarose gel with a clean, sharp scalpel. Minimize the size of the gel slice by removing extra agarose. </dd> |
− | <dd>Weigh the gel slice in a colorless tube. Add 3 volumes of Buffer QG to 1 volume of gel (100 mg ~ 100 µl). For example, add 300 µl of Buffer QG to each 100 mg of gel. For >2% agarose gels, add 6 volumes of Buffer QG. The maximum amount of gel slice per QIAquick column is 400 mg; for gel slices >400 mg use more than one QIAquick column. </dd> | + | <dd>2. Weigh the gel slice in a colorless tube. Add 3 volumes of Buffer QG to 1 volume of gel (100 mg ~ 100 µl). For example, add 300 µl of Buffer QG to each 100 mg of gel. For >2% agarose gels, add 6 volumes of Buffer QG. The maximum amount of gel slice per QIAquick column is 400 mg; for gel slices >400 mg use more than one QIAquick column. </dd> |
− | <dd>Incubate at 50°C for 10 min (or until the gel slice has completely dissolved). To help dissolve gel, mix by vortexing the tube every 2–3 min during the incubation. IMPORTANT: Solubilize agarose completely. For >2% gels, increase incubation time. | + | <dd>3. Incubate at 50°C for 10 min (or until the gel slice has completely dissolved). To help dissolve gel, mix by vortexing the tube every 2–3 min during the incubation. IMPORTANT: Solubilize agarose completely. For >2% gels, increase incubation time. |
After the gel slice has dissolved completely, check that the color of the mixture is yellow (similar to Buffer QG without dissolved agarose). If the color of the mixture is orange or violet, add 10 µl of 3 M sodium acetate, pH 5.0, and mix. The color of the mixture will turn to yellow. The adsorption of DNA to the QIAquick membrane is efficient only at pH ≤7.5. Buffer QG contains a pH indicator which is yellow at pH ≤7.5 and orange or violet at higher pH, allowing easy determination of the optimal pH for DNA binding. </dd> | After the gel slice has dissolved completely, check that the color of the mixture is yellow (similar to Buffer QG without dissolved agarose). If the color of the mixture is orange or violet, add 10 µl of 3 M sodium acetate, pH 5.0, and mix. The color of the mixture will turn to yellow. The adsorption of DNA to the QIAquick membrane is efficient only at pH ≤7.5. Buffer QG contains a pH indicator which is yellow at pH ≤7.5 and orange or violet at higher pH, allowing easy determination of the optimal pH for DNA binding. </dd> | ||
− | <dd>Place a QIAquick spin column in a provided 2 ml collection tube. | + | <dd>4. Place a QIAquick spin column in a provided 2 ml collection tube. |
To bind DNA, apply the sample to the QIAquick column, and centrifuge for 1 min. The maximum volume of the column reservoir is 800 µl. For sample volumes of more than 800 µl, simply load and spin again. </dd> | To bind DNA, apply the sample to the QIAquick column, and centrifuge for 1 min. The maximum volume of the column reservoir is 800 µl. For sample volumes of more than 800 µl, simply load and spin again. </dd> | ||
− | <dd>Discard flow-through and place QIAquick column back in the same collection tube. Collection tubes are re-used to reduce plastic waste. </dd> | + | <dd>5. Discard flow-through and place QIAquick column back in the same collection tube. Collection tubes are re-used to reduce plastic waste. </dd> |
− | <dd> | + | <dd>6. To wash, add 0.75 ml of Buffer PE to QIAquick column and centrifuge for 1 min. Note: If the DNA will be used for salt sensitive applications, such as blunt-end ligation and direct sequencing, let the column stand 2–5 min after addition of Buffer PE, before centrifuging. </dd> |
− | <dd> | + | <dd>7. Discard the flow-through and centrifuge the QIAquick column for an additional 1 min at ≥10,000 x g (~13,000 rpm). IMPORTANT: Residual ethanol from Buffer PE will not be completely removed unless the flow-through is discarded before this additional centrifugation.</dd> |
− | <dd> | + | <dd>8. Place QIAquick column into a clean 1.5 ml microcentrifuge tube. </dd> |
− | <dd> | + | <dd>9. To elute DNA, add 50 µl of Buffer EB (10 mM Tris·Cl, pH 8.5) or H2O to the center of the QIAquick membrane and centrifuge the column for 1 min at maximum speed. Alternatively, for increased DNA concentration, add 30 µl elution buffer to the center of the QIAquick membrane, let the column stand for 1 min, and then centrifuge for 1 min. IMPORTANT: Ensure that the elution buffer is dispensed directly onto the QIAquick membrane for complete elution of bound DNA. The average eluate volume is 48 µl from 50 µl elution buffer volume, and 28 µl from 30 µl. Elution efficiency is dependent on pH. The maximum elution efficiency is achieved between pH 7.0 and 8.5. When using water, make sure that the pH value is within this range, and store DNA at –20°C as DNA may degrade in the absence of a buffering agent. The purified DNA can also be eluted in TE (10 mM Tris·Cl, 1 mM EDTA, pH 8.0), but the EDTA may inhibit subsequent enzymatic reactions. |
</dd> | </dd> | ||
Line 286: | Line 287: | ||
<p><b>Protocol:</b><p> | <p><b>Protocol:</b><p> | ||
<dl> | <dl> | ||
− | <dd> | + | <dd>1. Blank the nanometer with 2µL the buffer you used to elute your sample</dd> |
− | <dd>put 2 µL of the sample on the nanometer, and average the result.</dd> | + | <dd>2. put 2 µL of the sample on the nanometer, and average the result.</dd> |
</dl> | </dl> | ||
</div> | </div> |
Revision as of 08:44, 15 September 2015
Methods
On this page you can find all of the methods and protocols used in the lab to obtain our results. For some techniques, we included some basic theory, since it is a prerequisite to get acquainted with the theory behind these techniques before using them. To learn more about them, click the titles below!
Contact
Address: Celestijnenlaan 200G room 00.08 - 3001 Heverlee
Telephone n°: +32(0)16 32 73 19
Mail: igem@chem.kuleuven.be