Difference between revisions of "Team:Amoy/Interlab"
Line 340: | Line 340: | ||
<p class="main_p">Table 2 presents the Fluorescence we measured, using three biological replicates of each device, alongside controls for LB media plus antibiotic and background value. </p> | <p class="main_p">Table 2 presents the Fluorescence we measured, using three biological replicates of each device, alongside controls for LB media plus antibiotic and background value. </p> | ||
<img style="width: 80%" class="main_img" src="https://static.igem.org/mediawiki/2015/5/5d/Interlab_table2.png" /> | <img style="width: 80%" class="main_img" src="https://static.igem.org/mediawiki/2015/5/5d/Interlab_table2.png" /> | ||
− | <table align="center" width="800px" height | + | <table align="center" width="800px" height="240px"> |
<caption style="border-color: rgb(221, 221, 221);"> | <caption style="border-color: rgb(221, 221, 221);"> | ||
<strong><span style="font-size: 20px;">Table 2a.</span></strong><span style="font-size: 20px;"> Fluorescence (485 ex/520 em)for 3 devices with different promoters coding for GFP as read in a FLUOstar omega microplate reader. Units are arbitrary.</span> | <strong><span style="font-size: 20px;">Table 2a.</span></strong><span style="font-size: 20px;"> Fluorescence (485 ex/520 em)for 3 devices with different promoters coding for GFP as read in a FLUOstar omega microplate reader. Units are arbitrary.</span> | ||
Line 516: | Line 516: | ||
<br/> | <br/> | ||
</p> | </p> | ||
− | <table width="600px" align="center" height | + | <table width="600px" align="center" height="240px"> |
<caption style="border-color: rgb(221, 221, 221);"> | <caption style="border-color: rgb(221, 221, 221);"> | ||
<span style="font-size: 20px;"><strong>Table 2b.</strong> Fluorescence (485 ex/520 em)for 3 devices with different promoters coding for GFP as read in a FLUOstar omega microplate reader. Units are arbitrary.</span> | <span style="font-size: 20px;"><strong>Table 2b.</strong> Fluorescence (485 ex/520 em)for 3 devices with different promoters coding for GFP as read in a FLUOstar omega microplate reader. Units are arbitrary.</span> |
Revision as of 07:25, 28 August 2015
INTERLAB
1. Introduction
The goal of the Interlab study is to obtain fluorescence data for three specific genetic devices expressing GFP from iGEM teams around the world. This year, three devices were cloned by ourselves, and one positive control and one negative control were provided by the registry. Using a plate reader, fluorescence measurements were obtained in arbitrary units. The results show increased fluorescence in the stronger promoter expected. After the experiment, three required devices were created: J23101+I13504 in the pSB3K3 backbone. J23106+I13504 in the pSB1C3 backbone. J23117+I13504 in the pSB1C3 backbone. Devices constructed in pSB1C3 are high copy number plasmids, hence a strong fluorescence can be obviously observed by naked eyes. While for device J23117 + I13504, the promoter strength is the weakest, we could barely observe any fluorescence under natural light.
Figure 1. GFP generator with different promoters under natural light. 1. J23101+I13504 in DH5α; 2. J23106+I13504 in DH5α; 3. J23117+I13504 in DH5α.
Figure 2. Centrifugation of bacteria. 1. J23101+I13504; 2. J23106+I13504; 3. J23117+I13504; 4. Positive control (I20270); 5. Negative control (R0040 in pSB1C3)
Digestion Verification
Four devices (J23101+I13504/J23106+I13504/J23117+I13504/I20270) are double digested at EcoR I and Pst I restriction sites to verify the target parts. The restriction map is shown as Figure 3. As expected, the second bands are supposed to be aroud 1000bp, which is consistent with what we saw on the map.
Figure 3. Restriction map of digestion verification. 2000plus DNA marker.
1. Double digestion of J23101+I13504 (constructed plasmid) 2. Double digestion of J23106+I13504 (constructed plasmid) 3. Double digestion of J23117+I13504 (constructed plasmid) 4. Double digestion of I20270 in pSB1C3 backbone (provided in registry)
DNA sequencing
All created parts are verified by DNA sequencing, as shown in Figure 4.
Figure 4. DNA sequencing results of three required devices, analyzed by DNAMAN software.
2. Protocol
1. Transform constructed plasmids into DH5α competent cells, grown in incubator for 12 hrs at 37℃. 2. Add 5 mL LB medium with antibiotic (Chloramphenicol 35μg/ml) into test tubes, choose monoclonal cells from the petri dish. 3. Set up 3 biological replicates of each device. Cultures were grown in test tubes for 16 hours at 37℃, shaking at 200 rpm. 4. Obtain initial OD 600 measurement of overnight cultures. Then dilute each sample to an OD of 0.5 (margin of error: 5%). 5. Set instrument to measure GFP. 6. Measurements of absorbance and fluorescence: (1) OD 600 Device: Spectrophotometer Wavelengths: 600 nm absorption. (2) Fluorescence Device: FLUOstar omega microplate reader, 96-well plates. Wavelengths: 485 nm excitation, 520 nm emission.
3. Measurements
Absorbance at 600 nm was measured for each of the three cultures, alongside controls for media and contamination background. The dilution required for each sample has been calculated. Table 1 presents the re-measurement of samples on OD 600, and all OD 600 are within 5% of 0.5 (0.475-0.525).
A | B | C | D | E | F | |
1 | 0.509 | 0.500 | 0.502 | 0.484 | 0.479 | 0.089 |
2 | 0.499 | 0.500 | 0.507 | 0.519 | 0.497 | 0.074 |
3 | 0.505 | 0.497 | 0.503 | 0.483 | 0.509 | 0.080 |
G |
Table1:Absorbance at 600 nm for 3 required devices with different promoters coding for GFP as read in spectrophotometer. Units are arbitrary.
'A'wells=cloned device (J23101+I13504); 'B'wells=cloned device (J23106+I13504); 'C'wells=cloned device (J23117+I13504); 'D'wells=negative control (R0040 in PSB1C3 backbone); 'E'wells=positive control (I20270 in PSB1C3 backbone); 'F'wells=LB media plus antibiotic (chloramphenicol only); 'G'wells=Non-inoculate culture;
Table 2 presents the Fluorescence we measured, using three biological replicates of each device, alongside controls for LB media plus antibiotic and background value.
A1 | A2 | A3 | B1 | B2 | B3 | C1 | C2 | C3 | |
replicate1 | 57850 | 55881 | 55501 | 36054 | 34549 | 34799 | 958 | 960 | 957 |
replicate2 | 55682 | 54154 | 53233 | 37165 | 35969 | 35697 | 1098 | 1073 | 1071 |
replicate3 | 56413 | 54693 | 53803 | 33475 | 31901 | 31920 | 1401 | 1381 | 1375 |
F | 6937 | 6892 | 7183 | ||||||
G | 114 | 108 | 105 |
D1 | D2 | D3 | E1 | E2 | E3 | |
replicate1 | 802 | 785 | 777 | 10593 | 10104 | 10021 |
replicate2 | 700 | 769 | 752 | 10758 | 10161 | 10136 |
replicate3 | 1026 | 1022 | 1051 | 10990 | 10357 | 10357 |
F | ||||||
G |
Table2:Fluorescence(485 ex/520 em)for 3 devices with different promoters coding for GFP as read in a FLUOstar omega microplate reader. Units are arbitrary.
'A1-A3'wells=Cloned device J23101+I13504. Three technical replicates (horizontal), three biological replicates(vertical). 'B1-B3'wells=Cloned device J23106+I13504. Three technical replicates (horizontal), three biological replicates (vertical). 'C1-C3'wells=Cloned device J23117+I13504. Three technical replicates (horizontal), three biological replicates (vertical). 'D1-D3'wells=negative control device (only promoter). Three technical replicates (horizontal), three biological replicates (vertical). 'E1-E3'wells=positive control device (I20270 in PSB1C3 backbone); 'F'wells=LB media plus antibiotic (chloramphenicol only). Sampled three times. 'G'wells=non-inoculate cultures
Data was processed as follows: 1. Background absorbance was removed by subtracting the value of F wells. 2. Background fluorescence was controlled for by subtracting the value of F wells. 3. Calculate the mean value and standard deviation of the 3 biological replicates and 3 technical replicates. 4. Evaluate the variability of chosen analysis technique.
A1 | A2 | A3 | B1 | B2 | B3 | C1 | C2 | C3 | D1 | D2 | D3 | E1 | E2 | E3 | |
mean | 56766 | 54909 | 54179 | 36610 | 34140 | 34139 | 1028 | 1138 | 1134 | 751 | 859 | 860 | 10676 | 10207 | 10171 |
S.D. | 1102.99 | 883.59 | 1179.83 | 1893.04 | 2064.66 | 1973.19 | 226.44 | 217.90 | 216.08 | 166.76 | 141.68 | 165.88 | 199.44 | 132.71 | 170.76 |
C.V. | 1.94 | 1.61 | 2.18 | 5.17 | 6.05 | 5.78 | 22.02 | 19.15 | 19.05 | 22.21 | 16.49 | 19.29 | 1.87 | 1.30 | 1.68 |
Table 3. Comparison of fluorescence in terms of three technical replicates for three different constructs expressing GFP. D1-D3-negtive controls, E1-E3-positive controls.S.D-standard deviation. C.V-coefficient of variation.
4. Provenance
Q: Who did the actual work to acquire these measurements? A: Beibei Fang. Q: What other people should be credited for these measurements? A: Shouqiang Hong, Na Li. Q: On what dates were the protocols run and the measurements taken? A: Required devices were constructed by 30th June 2015. All samples were measured on 12th August 2015.
5. Appendix
Raw Data (Ex485/Em520)
Technical replicate1:
1 | 2 | 3 | 4 | 5 | |
A | mean | ||||
B | |||||
C | 57850 | 55682 | 56413 | 56648 | |
D | 36054 | 37165 | 33475 | 35565 | |
E | 958 | 1098 | 1401 | 1152 | |
F | 802 | 700 | 1026 | 843 | |
G | 10593 | 10758 | 10990 | 10780 | |
H | 6937 | 6892 | 7183 | 7004 |
Technical replicate2:
1 | 2 | 3 | 4 | 5 | |
A | mean | ||||
B | |||||
C | 55881 | 54154 | 54693 | 55018 | |
D | 34549 | 35969 | 31901 | 35259 | |
E | 960 | 1073 | 1381 | 1017 | |
F | 785 | 769 | 1022 | 777 | |
G | 10104 | 10161 | 10357 | 10133 | |
H | 6802 | 6783 | 7072 | 6793 |
Technical replicate3:
1 | 2 | 3 | 4 | 5 | |
A | mean | stdv | |||
B | |||||
C | 55501 | 53233 | 53803 | 54179 | 1180 |
D | 34799 | 35697 | 31920 | 34139 | 1973 |
E | 957 | 1071 | 1375 | 1134 | 1216 |
F | 777 | 752 | 1051 | 860 | 166 |
G | 10021 | 10136 | 10357 | 10171 | 171 |
H | 6783 | 6762 | 6989 | 6845 | 125 |
6. Reference
1. Anderson,C., Berkley iGEM Team., (2006). Anderson Promoter Collection. Registry of Standard Biological Parts. 2. http://parts.igem.org/Promoters/Catalog/Anderson [Accessed 19/09/2014] 3. https://2014.igem.org/Team:XMU-China/Project_Interlab 4. https://2014.igem.org/Team:Imperial/InterLab_Study