Difference between revisions of "Team:Leicester/Measurement"
Line 43: | Line 43: | ||
<li><b>Transforming:</b> Transform parts into chemically competent bacteria</li> | <li><b>Transforming:</b> Transform parts into chemically competent bacteria</li> | ||
<li><b>Minipreps:</b>Required in isolating the required plasmid, for example the plamsids consisting of ligated parts </li> | <li><b>Minipreps:</b>Required in isolating the required plasmid, for example the plamsids consisting of ligated parts </li> | ||
− | <li><b>Nanodrops</b> </li> | + | <li><b>Nanodrops</b> Allows to determine the amount of DNA present in a given solution, the higher present will </li> |
<li><b>Ligations:</b> Use of ligase to ligate parts together </li> | <li><b>Ligations:</b> Use of ligase to ligate parts together </li> | ||
<li><b>Digestions:</b> Digesting of ligated parts but also to remove the parts from the plasmid backbone presented in</li> | <li><b>Digestions:</b> Digesting of ligated parts but also to remove the parts from the plasmid backbone presented in</li> | ||
Line 63: | Line 63: | ||
<h2 id="diff"> Discussion and Difficulties </h2> | <h2 id="diff"> Discussion and Difficulties </h2> | ||
− | <p>From the results obtained it can be seen that Device 1 had the highest fluorescence value, this was also confirmed by visually looking at the bacteria that consisted of Device 1. This is excluding the lower fluorescence value of the biological replicate 2, which may just be an anomaly. </p> | + | <p>From the results obtained it can be seen that Device 1 had the highest fluorescence value, this was also confirmed by visually looking at the bacteria that consisted of Device 1 but also from the data that we have obtained. This is excluding the lower fluorescence value of the biological replicate 2, which may just be an anomaly. </p> |
<p>However, Device 3 was found to have very minute fluorescence, this was observed visually but also from the data that we obtained from the fluorescence readings. One reason there is a very minute fluorescence could be due to background fluorescence from the TBE buffer that we used rather than actual fluorescence. Another is the possibility that there was no device in the bacteria. To analytically prove that the Device 3 that we had made from ligating the parts was accurate we had done restriction digests of Device 3 using enzymes …………… and then done gel electrophoresis. From the figure below you can see that both parts were present such we can conclude that the promoter must be very weak and such cannot be detected. If more time was on hand we would have been able to have sequenced the plasmid itself.</p> | <p>However, Device 3 was found to have very minute fluorescence, this was observed visually but also from the data that we obtained from the fluorescence readings. One reason there is a very minute fluorescence could be due to background fluorescence from the TBE buffer that we used rather than actual fluorescence. Another is the possibility that there was no device in the bacteria. To analytically prove that the Device 3 that we had made from ligating the parts was accurate we had done restriction digests of Device 3 using enzymes …………… and then done gel electrophoresis. From the figure below you can see that both parts were present such we can conclude that the promoter must be very weak and such cannot be detected. If more time was on hand we would have been able to have sequenced the plasmid itself.</p> |
Revision as of 17:19, 8 September 2015
Overview
As a team we decided that we would do some extra work during our time doing the iGEM project this such that we entered to take part in the Interlab Measurement study. The study requires us to look at the fluorescence of given gene circuits made up of parts found in the 2015 Distribution Kits.
The study requires producing 3 devices each consisting of a promoter sequence (depicted as different coloured arrows on Figure 1) and Green Fluorescence Protein (GFP) intermediate (I13504). Each of the devices are shown below:
- Device 1 - J23101 + I13504
- Device 2 - J23106 + I13504
- Device 3 - J23117 + I13504
As part of the Interlab study, we then did extra credit where we had get biological and technical replicates of each device. They have been defined as such:
- Biological Replicate - This is where there are different biological material in each replicate
- Technical Replicate - This is where the biological material of each replicate is the same. For example looking at a plate consisting of a particular device, the colonies that are very close to one another are assumed to be made up of the same biological material such they are inoculated three times.
Methodology
In order to conudct the measurement study we had to use a range of different methods. This included:
- Transforming: Transform parts into chemically competent bacteria
- Minipreps:Required in isolating the required plasmid, for example the plamsids consisting of ligated parts
- Nanodrops Allows to determine the amount of DNA present in a given solution, the higher present will
- Ligations: Use of ligase to ligate parts together
- Digestions: Digesting of ligated parts but also to remove the parts from the plasmid backbone presented in
- Gel electrophoresis: To determine the fragments produced from restriction digests of the ligated parts to ensure that the parts we require were ligated together.
Results
Fluorescence results for the Interlab study were obtained using the BMG LABTECH FLUOstar Omega Microplate Reader. We placed all the replicates (technical and biological) on a black based 96 well plate. Results were obtained in the format of arbitrary fluorescence unit/OD 600
Microplate Reader Settings
- Emission - EMS20
- Excitation - 485-12nm
- No. of flashes per well- 20
All results from each device were then placed in the format of graphs as such:
Discussion and Difficulties
From the results obtained it can be seen that Device 1 had the highest fluorescence value, this was also confirmed by visually looking at the bacteria that consisted of Device 1 but also from the data that we have obtained. This is excluding the lower fluorescence value of the biological replicate 2, which may just be an anomaly.
However, Device 3 was found to have very minute fluorescence, this was observed visually but also from the data that we obtained from the fluorescence readings. One reason there is a very minute fluorescence could be due to background fluorescence from the TBE buffer that we used rather than actual fluorescence. Another is the possibility that there was no device in the bacteria. To analytically prove that the Device 3 that we had made from ligating the parts was accurate we had done restriction digests of Device 3 using enzymes …………… and then done gel electrophoresis. From the figure below you can see that both parts were present such we can conclude that the promoter must be very weak and such cannot be detected. If more time was on hand we would have been able to have sequenced the plasmid itself.