Difference between revisions of "Team:KU Leuven/Research/Methods"
Line 164: | Line 164: | ||
<br/> | <br/> | ||
<dt>Day 2</dt> | <dt>Day 2</dt> | ||
− | <dd> | + | <dd>1. Pick a single colony from your plate and grow it in 1-3 mL salt free LB overnight in 37°C.</dd> |
<dt>Day 3: </dt> | <dt>Day 3: </dt> | ||
<dd>1. Grow 300-400 mL cells (without salt) in 37°C untill the OD reaches 0.6 (use a starting culture).</dd> | <dd>1. Grow 300-400 mL cells (without salt) in 37°C untill the OD reaches 0.6 (use a starting culture).</dd> | ||
Line 248: | Line 248: | ||
<dd> 2. Transfer up to 800 µL of the solution from step 1 (or optional step 2) to the GeneJET purification column. Centrifuge for 30-60 s. Discard the flow-through. Notes. If the total volume exceeds 800 µL, the solution can be added to the column in stages. After the addition of 800 µL of solution, centrifuge the column for 30-60 s and discard flowthrough. Repeat until the entire solution has been added to the column membrane. Close the bag with GeneJET Purification Columns tightly after each use! </dd> | <dd> 2. Transfer up to 800 µL of the solution from step 1 (or optional step 2) to the GeneJET purification column. Centrifuge for 30-60 s. Discard the flow-through. Notes. If the total volume exceeds 800 µL, the solution can be added to the column in stages. After the addition of 800 µL of solution, centrifuge the column for 30-60 s and discard flowthrough. Repeat until the entire solution has been added to the column membrane. Close the bag with GeneJET Purification Columns tightly after each use! </dd> | ||
<dd>3. Add 700 µL of Wash Buffer (diluted with the ethanol as described on p. 3) to the GeneJET purification column. Centrifuge for 30-60 s. Discard the flow-through and place the purification column back into the collection tube.</dd> | <dd>3. Add 700 µL of Wash Buffer (diluted with the ethanol as described on p. 3) to the GeneJET purification column. Centrifuge for 30-60 s. Discard the flow-through and place the purification column back into the collection tube.</dd> | ||
− | <dd>Transfer the GeneJET purification column to a clean 1.5 mL microcentrifuge tube (not included). Add 50 µL of Elution Buffer to the center of the GeneJET purification column membrane and centrifuge for 1 min.</dd> | + | <dd>4. Transfer the GeneJET purification column to a clean 1.5 mL microcentrifuge tube (not included). Add 50 µL of Elution Buffer to the center of the GeneJET purification column membrane and centrifuge for 1 min.</dd> |
<p><b>Note.</b> | <p><b>Note.</b> | ||
For low DNA amounts the elution volumes can be reduced to increase DNA concentration. An elution volume between 20-50 µL does not significantly reduce the DNA yield. However, elution volumes less than 10 µL are not recommended. If DNA fragment is >10 kb, prewarm Elution Buffer to 65 °C before applying to column. If the elution volume is 10 µL and DNA amount is ≥5 µg, incubate column for 1 min at room temperature before centrifugation.<p></dd> | For low DNA amounts the elution volumes can be reduced to increase DNA concentration. An elution volume between 20-50 µL does not significantly reduce the DNA yield. However, elution volumes less than 10 µL are not recommended. If DNA fragment is >10 kb, prewarm Elution Buffer to 65 °C before applying to column. If the elution volume is 10 µL and DNA amount is ≥5 µg, incubate column for 1 min at room temperature before centrifugation.<p></dd> | ||
− | <dd> | + | <dd>5. Discard the GeneJET purification column and store the purified DNA at -20 °C. </dd> |
<dl> | <dl> | ||
</div> | </div> |
Revision as of 08:46, 15 September 2015
Methods
On this page you can find all of the methods and protocols used in the lab to obtain our results. For some techniques, we included some basic theory, since it is a prerequisite to get acquainted with the theory behind these techniques before using them. To learn more about them, click the titles below!
Contact
Address: Celestijnenlaan 200G room 00.08 - 3001 Heverlee
Telephone n°: +32(0)16 32 73 19
Mail: igem@chem.kuleuven.be