Team:Freiburg/Results/Cellfree

""

Results: Cell-free Expression

The purpose of cell-free expression in the DiaCHIP is to copy DNA templates into a protein microarrays on demand. To enable antibody detection with this protein microarray, the single antigen spots have to be covered with a dense layer of antigens. Thus, the expression efficiency of the cell-free system has to be optimized to produce a sufficient amount of target proteins within a timespan that is reasonable for preparation of the DiaCHIP in the suggested applications.

One of the key factors influencing expression efficiency is the design of the expression vector. Therefore, we started with the design of a vector based on pSB1C3 (LINK) that would allow successful cell-free expression (LINK). Additionally, we received an expression vector containing a GFP coding sequence from the BIOSS toolbox (LINK/MAP). The third vector we used for our experiments was the pBESTlucTM (LINK/MAP) encoding a luciferase for performing the luciferase assay.

However, the most important thing is of course the expression system itself. We obtained

  • a commercially available expression kit based on an E. coli lysate
  • an established cell-free expression mix from the group of Dötsch/Bernhard
  • and additionally established the production of our own DiaMIX, based on [REF.].

We also provide the protocol in order to give future iGEM Teams the possibility to produce their cell-free expression mix in a low-budget version themselves.

First Successful Expression

Figure 1: Cell-free expression of GFP. Fluorescing GFP could be detected via fluorescence microscopy after cell-free expression (A). Picture taken of the negative control (B). For detailed reaction performance see our labjournal.

Before using our DiaMIX in the microfluidic chamber, we performed some initial experiments in vitro in tubes, and at a later time, in well-plates. First we weren't able to express anything. This was due to several factors, like the pH value of our mix. It has to be adjusted in an rather narrow range between 7 and 8. With only pH paper at hand, this was not easy. The pH value is also crucial for the solubility of certain chemicals. After adjustment of the pH, further parameters were adapted and the source of errors narrowed down. As prime sources for errors the lysate and the premix were identified. Repeated preparation and more experience took care of this.

In the end, the premix itself, proved to be our greatest source for errors and prepared once more. From then on we could record basal expression indicating that we further optimized our system.

Variation of Mg(OAc)2 Concentration

Figure 2: Impact of Mg(OAc)2 addition during cell-free expression of Luciferase. the regular feeding every 20 min with 100mM MgOAc shows an increase of expression to half of that of the commercial kit.

At first, we investigated the influence of magnesium acetate (Mg(OAc)2) on our reaction. In a work of Kim et al. [REF.] we read about the enhancement of cell-free expression, by regularly adding a particular amount. We performed expression experiments where reactions were fed with small amounts of Mg(OAc)2 while others were not. The repeated addition of small amounts of magnesium (100 nmol) every 20 minutes during the reaction was found to increase expression levels and was therefore implemented for future experiments. This was done by pipetting 0.5 μl of a 10 μM magnesium acetate solution into the reaction tube whilst keeping it inside the thermomixer. Positive effects towards expression were immediately visible in a subsequently conducted luciferase assay. Indeed, we could observe an effect upon addition of the supplement (see figure 2). However, the actual impact of feeding varied a lot in the experiments (LINK zu labjournal), even among reactions with the same components.

Figure 3: Variation of Mg(OAc)2 concentrations (12-16 mM)in cell-free expression. Cell-free expression of pBESTlucTM and subsequent validation via luciferase assay. Experiment was performed in Triplicates.

As supplying a reaction lasting for two hours with some additional chemicals every 20 minutes is quite time consuming, we thought about simply varying the initial concentration of Mg(OAc)>sub>2 in the reaction mix. From personal discussions with leading scientist on the filld of Cell-free expression we were adviced to adjust our mix to an concentration of 15-18 mM Mg+. Therefore, we expressed the pBESTlucTM (LINK) with our DiaMIX at concentrations between 12-16 mM to compare the expression via luciferase assay. The result is shown in figure 3 and reveals the optimal amount of Mg(OAc)2 at a starting concentration of 12 mM.



Variation of DNA Concentration

Figure 3: Variation of DNA concentration for cell-free expression. Results for concentrations of 0.02 µg/µl (A), 0.04 µg/µl (B), 0.1 µg/µl (C) and the negative control (D). Validation was performed via luciferase assay and analyzed in a microplate reader.

After establishing the best concentration of Mg(OAc)2 in our reactions we further investigated the optimal concentration of DNA added for expression. Again, pBESTlucTM (LINK) was expressed to allow the analysis via luciferase assay in a microplate reader. Triplicates for reactions of 50µl volumes were set up with amounts of DNA ranging from 1µg to 5µg, as well as a negative control without DNA. For this, a sequence of reactions was performed in parallel, reaching from 1 to 5 μg (per 50 μl reaction). Each reaction was performed in triplicates. As a negative control, the same conditions (37°C, 2 h, no shaking) were applied to a reaction where water was added instead of DNA. Luciferase was expressed using the pBESTlucTM vector and a luciferase assay was performed as described in protocols.

Figure 4: Variation of DNA concentration for cell-free expression. Results for concentrations of 0.02 µg/µl (A), 0.04 µg/µl (B), 0.1 µg/µl (C) and the negative control (D). Validation was performed via luciferase assay and analyzed in a microplate reader.

The optimal amount of DNA established for further experiments was 2 µg or 3 µg. To make later reactions more cost-efficient reactions 2 µg of DNA per 50 µl were used.



Comparison with Commercial Kit

Figure 5: Cell-free GFP expression over time. Comparison of the commercial kit with the DiaMIX was performed using our pQE60 HA-GFP-12xHis vector. Relative fluorescence was measured every minute over 2 hours. As negative control, the fluorescence of the respective mix without adding DNA was recorded. The experiment was performed in triplicates and the values normalized to air. A propagation of uncertainty was performed.

Having optimized our self-prepared, low-budget cell-free expression mix, we compared it to a commercially available kit and thereby were able to make a statement about the functionality of our DiaMIX. As already shown on the main results page we set up an experiment using DNA of the pQE HA-GFP-12xHis vector, as an external standard that had already demonstrated to perform well in a cell-free expression system. Furthermore, a from this years iGEM team especially for the application designed vector was used that carried a gene for GFP and an N-terminal 10xHis and a Spy-tag on the other side (This sentence does not work...). Non-coding areas surrounding the GFP gene were optimized for cell free expression. (link) As seen in Figure 5, the DiaMIX shows a higher fluorecence compared to the commercial kit. Even when the higher basal fluorescence is taken into account. This is an effect of the components in the premix. The commercial kit shows an initial drop in fluorescence.

Figure 5: Cell-free GFP expression over time. Comparison ot the commercial kit with the DiaMIX was performed using the self-synthesized Spy-GFP-10xHis. Relative fluorescence was measured every minutes over 2 hours. As a negative control, the fluorescence of the respective mix without adding DNA was recorded. The experiment was performed in triplicates and the values normalized to air. A propagation of uncertainty was performed.

This was observed during every measurement and seems to be an fundamental characteristic of the mix that we attributed quenching effects. (Figure 6 shows the performance of our self-designed vector with tha DiaMIX and the commercial mix. As can be observed, the DiaMIX still performs better than the commercial kit. However, the difference is not as obvious as before. This indicates that the DNA does not yet posses an optimal structure for an effective performance in a cell-free system. This could be due to differences in the 5' upstream sequence which was demonstrated to have great influence on the initiation of transcription. Furthermore, tag sin the beginning of the coding sequence also manipulate the expression level as shown by ???
Our self-produced DiaMIX performed about as good as the commercial kit as it is shown in figure 5. Compared to the background, an expression time of two hours resulted in a 2-fold increase of relative fluorescence in both systems. The background fluorescence was estimated by the negative control.)

iRIf Measurement of Cell-free Expressed GFP

Figure 6: iRIf measurement of cell-free expressed GFP.

Encouraged by all the promising results that were obtained, we decided to make the next step and broaden the verification methods of our cell-free expressed proteins by using the iRIf technology. We validated cell-free expressed GFP by pipetting a small amount of the reaction directly onto a glass slide with different surfaces. We checked for the detectability of the protein as well as for the results on specific and unspecific surfaces.
We were able to detect GFP expressed with the DiaMIX as seen in figure 6. Elaborate results for the iRIf experiments performed with cell-free expressed proteins can be found on this results page.

Step by Step Validation

Immobilizing DNA on PDMS

Figure 1: DNA immobilization on activated PDMS. PCR amplification of the expression cassette was performed with an amino-labelled reverse primer and a Cy3-labelled forward primer. Immobilized DNA is visualized by Cy3 fluorescence..

Insert results of immobilizing DNA on PDMS


















On-slide Cell-free Expression

The last step towards a final application in the DiaCHIP is the performance of a cell-free expression reaction between the silicone and the glass slide of the microfluidic chamber. Immobilized DNA on the PDMS slide should be transcribed and translated into proteins. Due to time constraints, we were not able to optimize this process. Nonetheless, initial results can be found on this results page.

In-chamber Expression of GFP

Insert results of on-slide expression of GFP