Difference between revisions of "Team:Bielefeld-CeBiTec/Results/HeavyMetals"

Line 621: Line 621:
 
</div>
 
</div>
  
<p> With this sensor no production of sfGFp via fluorescence level change could be detected. Therefore this sensor is not suitable for approach. Therefore no <i> in vitro </i> data using CFPS were taken.</p></br>
+
<p> The data for our nickel sensor show a trend that differs for that of the other sensors. There is no indication for a working sensor <i>in vivo </i>. There is a fluorescence signal but it decreases in the first 5 hours. After reaching a minimum the fluorescence increases slowly. Additionally there is no difference in fluorescence as response to various nickel concentration. Nickels influence on the cells could be lead to a fallout which could result in  decrease of fluorescence.
 +
With this sensor no production of sfGFp via fluorescence level change could be detected. Therefore this sensor is not suitable for approach. Therefore no <i> in vitro </i> data using CFPS were taken.</p></br>
  
 
<h2>To sum it up</h2>
 
<h2>To sum it up</h2>

Revision as of 11:31, 18 September 2015

iGEM Bielefeld 2015


Heavy Metals

To make a long story short.

Adjusting the detection limit
Influence of heavy metals on the growth of E.coli KRX. The tested concentrations were 20 µg/L lead, 60 µg/L mercury, 60 µg/L chromium, 80 µg/L nickel, 40 mg/L copper, which represent ten times the WHO guideline. The influence of arsenic was not tested as E. coli is known to be resistant to arsenic.

We tested our heavy metal biosensors in Escherichia coli as well as in our cell-free protein synthesis.

Prior to the in vivo characterization, we tested whether the heavy metals have a negative effect on the growth of E. coli.

As can be seen from the figure, we observed no significant difference between the growth in the presence of heavy metals and the controls. This first experiment showed us that in vivo characterization of these sensors is possible. Most cultivations for in vivo characterization were performed in the BioLector. Due to the accuracy of this device, we could measure our samples in duplicates. Subsequently, all functional biosensors were tested in vitro.

Click on the test strip for the results of our biosensor tests in E. coli and in our CFPS:

teststrip

To sum it all up

We have characterized heavy metal sensors for arsenic, chromium, copper, lead, mercury and nickel. The results for our nickel characterization indicated that the constructed nickel sensor is not suitable for our test strip. The sensors for lead and chromium showed great potential, as they showed responses to chromium or lead, but require further optimization. Copper, our new heavy metal sensor, worked as expected and was able to detect different copper concentrations. The already well-characterized sensors for arsenic and mercury were tested as well. While the arsenic sensor worked well in vivo, it requires some omptimization for the use in vitro. Mercury showed that a fully optimized sensor works very well in our in vitro system and has the potential to detect even lower concentrations than in vivo.