Difference between revisions of "Team:Bielefeld-CeBiTec/Results/HeavyMetals"

Line 207: Line 207:
 
<figcaption>Influence of arsenic on cell-free protein synthesis.</figcaption>
 
<figcaption>Influence of arsenic on cell-free protein synthesis.</figcaption>
 
</figure>
 
</figure>
<p>In order to test the arsenic sensor in our cell-free protein synthesis, we cloned a device that contains the arsenic operator between the T7 promoter and sfGFP with our optimized untranslated region (UTR). We tested this device in a cell extract that had been generated from cells expressing the arsenic repressor. We observed an induction when adding arsenic up to a concentration of 1.87 mg/L. As high arsenic concentrations inhibit the performance of the CFPS, we normalized the results for this effect. In the final application, this task is performed by our app.</p>
+
<p>In order to test the arsenic sensor in our cell-free protein synthesis, we cloned a device that contains the arsenic operator between the T7 promoter and sfGFP with our optimized untranslated region (UTR). We tested this device in a cell extract that had been generated from cells expressing the arsenic repressor. We observed an induction when adding arsenic up to a concentration of 1.87 mg/L. As high arsenic concentrations inhibit the performance of the CFPS, we normalized the results to this effect. In the final application, this task is performed by our app.</p>
  
  
<div class="row">
+
<div class="row" style="margin-bottom: 20px">
 
<div class="col-md-6">
 
<div class="col-md-6">
 
<figure style="width: 600px">
 
<figure style="width: 600px">
 
<figure style="width: 600px">
 
<figure style="width: 600px">
 
<a href="https://static.igem.org/mediawiki/2015/8/84/Bielefeld-CeBiTec_arsenic_invitro_uncorrected.png" data-lightbox="heavymetals" data-title="Induction of arsenic sensor <i>in vitro</i>. For this experiment, a cell extract which already containes the arsenic repressor was used. Error bars represent the standard deviation of three biological replicates."><img src="https://static.igem.org/mediawiki/2015/8/84/Bielefeld-CeBiTec_arsenic_invitro_uncorrected.png" alt="Adjusting the detection limit"></a>
 
<a href="https://static.igem.org/mediawiki/2015/8/84/Bielefeld-CeBiTec_arsenic_invitro_uncorrected.png" data-lightbox="heavymetals" data-title="Induction of arsenic sensor <i>in vitro</i>. For this experiment, a cell extract which already containes the arsenic repressor was used. Error bars represent the standard deviation of three biological replicates."><img src="https://static.igem.org/mediawiki/2015/8/84/Bielefeld-CeBiTec_arsenic_invitro_uncorrected.png" alt="Adjusting the detection limit"></a>
<figcaption>Induction of arsenic sensor in vitro. For this experiment, a cell extract which already containes the arsenic repressor was used. Error bars represent the standard deviation of three biological replicates.</figcaption>
+
<figcaption>Induction of arsenic sensor in vitro. For this experiment, a cell extract that already containes the arsenic repressor was used in combination with <a href=http://parts.igem.org/wiki/index.php?title=Part:BBa_K1758300">BBa_K1758300</a>. Error bars represent the standard deviation of three biological replicates.</figcaption>
 
</figure>
 
</figure>
 
</div>
 
</div>
 
<div class="col-md-6">
 
<div class="col-md-6">
 
<a href="https://static.igem.org/mediawiki/2015/0/03/Bielefeld-CeBiTec_arsenic_invitro_corrected.png" data-lightbox="heavymetals" data-title="Induction of arsenic sensor <i>in vitro</i>. For this experiment, a cell extract which already containes the arsenic repressor was used. Error bars represent the standard deviation of three biological replicates."><img src="https://static.igem.org/mediawiki/2015/0/03/Bielefeld-CeBiTec_arsenic_invitro_corrected.png" alt="Adjusting the detection limit"></a>
 
<a href="https://static.igem.org/mediawiki/2015/0/03/Bielefeld-CeBiTec_arsenic_invitro_corrected.png" data-lightbox="heavymetals" data-title="Induction of arsenic sensor <i>in vitro</i>. For this experiment, a cell extract which already containes the arsenic repressor was used. Error bars represent the standard deviation of three biological replicates."><img src="https://static.igem.org/mediawiki/2015/0/03/Bielefeld-CeBiTec_arsenic_invitro_corrected.png" alt="Adjusting the detection limit"></a>
<figcaption>Induction of arsenic sensor in vitro. For this experiment, a cell extract which already containes the arsenic repressor was used. Error bars represent the standard deviation of three biological replicates.</figcaption>
+
<figcaption>Induction of arsenic sensor in vitro. For this experiment, a cell extract which already containes the arsenic repressor was used in combination with <a href=http://parts.igem.org/wiki/index.php?title=Part:BBa_K1758300">BBa_K1758300</a>. The data were normalized to account for the negative effect of arsenic on cell extract performance. Error bars represent the standard deviation of three biological replicates.</figcaption>
 
</figure>
 
</figure>
 
</div>
 
</div>

Revision as of 18:58, 18 September 2015

iGEM Bielefeld 2015


Heavy Metals

Results

Adjusting the detection limit
Influence of heavy metals on the growth of E.coli KRX. The tested concentrations were 20 µg/L lead, 60 µg/L mercury, 60 µg/L chromium, 80 µg/L nickel, 40 mg/L copper, which represent ten times the WHO guideline. The influence of arsenic was not tested as E. coli is known to be resistant to arsenic.

We tested our heavy metal biosensors in Escherichia coli as well as in our cell-free protein synthesis.

Prior to the in vivo characterization, we tested whether the heavy metals have a negative effect on the growth of E. coli.

As can be seen from the figure, we observed no significant difference between the growth in the presence of heavy metals and the controls. This first experiment showed us that in vivo characterization of these sensors is possible. Most cultivations for in vivo characterization were performed in the BioLector. Due to the accuracy of this device, we could measure our samples in duplicates. Subsequently, all functional biosensors were tested in vitro.

Click on the test strip for the results of our biosensor tests in E. coli and in our CFPS:

teststrip

To summarize all

We have characterized heavy metal sensors for arsenic, chromium, copper, lead, mercury and nickel. The results for our nickel characterization indicated that the constructed nickel sensor is not suitable for our test strip. The sensors for lead and chromium showed great potential, as they showed responses to chromium or lead, but require further optimization. Copper, our new heavy metal sensor, worked as expected and was able to detect different copper concentrations. The already well-characterized sensors for arsenic and mercury were tested as well. While the arsenic sensor worked well in vivo, it requires some omptimization for the use in vitro. Mercury showed that a fully optimized sensor works very well in our in vitro system and has the potential to detect even lower concentrations than in vivo.