Difference between revisions of "Team:Sherbrooke/Results"
Nicolas.noel (Talk | contribs) m |
|||
Line 2: | Line 2: | ||
<html> | <html> | ||
− | < | + | <h1> Project Results</h1> |
− | < | + | <h2>Overview</h2> |
+ | <ul> | ||
+ | <li><a href="#Experimentations Results">Experimentations Results</a></li> | ||
+ | <li><a href="#Achievements">Achievements</a></li> | ||
+ | <li><a href="#Future Plans">Future Plans</a></li> | ||
+ | </ul> | ||
− | < | + | <span id="Experimentations Results"> </span> |
+ | <h2>Experimentations Results<h2> | ||
+ | <hr><hr><hr> | ||
+ | </br> | ||
+ | <h2>Project modules</h2> | ||
<ul> | <ul> | ||
− | <li> | + | <li><a href="#MC96">MC96</a></li> |
− | <li> | + | <li><a href="#MC1.5">MC1.5</a></li> |
− | <li> | + | <li><a href="#TAC">TAC</a></li> |
</ul> | </ul> | ||
+ | <span id="MC96"> </span> | ||
+ | <h2>MC96</h2> | ||
+ | <hr><hr> | ||
+ | <p> | ||
+ | A <a href="#MC96 Thermal Experimentations">thermal experimentation </a>has been the only experimentation done on the <i>MC96</i> module. | ||
+ | </p> | ||
+ | <span id="MC96 Thermal Experimentations"> </span> | ||
+ | <h3>Thermal experimentations</h3> | ||
+ | <hr> | ||
+ | <p> | ||
+ | Has no prototype has been built yet, the only results available are the ones from simulations. | ||
+ | </p> | ||
+ | <h4>Simulation Results</h4> | ||
+ | <p> | ||
+ | Some simulation has been done on earlier designs, | ||
+ | but none of the final design, due to the complexity of | ||
+ | simulating heat pipes. Thus, these results are not finals | ||
+ | and will surely improve with the addition of the heat pipes | ||
+ | between the Peltier elements and the 96-well aluminium mold. | ||
+ | </p> | ||
+ | <p> | ||
+ | The following figures represent the repartition of heat at | ||
+ | the beginning and the end of a heating speed test: | ||
+ | </p> | ||
+ | <p> <font color="red">MC96 Heating speed test image</font></p> | ||
+ | <p> | ||
+ | The final temperature has been achieved in <font color="red">70</font> seconds. | ||
+ | </p> | ||
− | < | + | <p> |
+ | The following figures represent the repartition of heat at | ||
+ | the beginning and the end of a cooling speed test: | ||
+ | </p> | ||
+ | <p> <font color="red">MC96 Cooling speed test image</font></p> | ||
+ | <p> | ||
+ | The final temperature has been achieved in <font color="red">135</font> seconds. | ||
+ | </p> | ||
− | < | + | <a href="#MC96">Back to MC96</a> |
+ | </br> | ||
+ | <a href="#Experimentations Results">Back to Experimentations Results</a> | ||
+ | </br> | ||
+ | <a href="#top_menu_under">Back to top</a> | ||
+ | <span id="MC1.5"> </span> | ||
+ | <h2>MC1.5</h2> | ||
+ | <hr><hr> | ||
+ | <p> | ||
+ | <a href="#MC1.5 Thermal Experimentations">Thermal</a> and <a href="#MC1.5 Magnetisation Experimentations">magnetisation</a> experimentations have been conduct to validate | ||
+ | the design of the <i>MC1.5</i> module. These are the results of those experimentations. | ||
+ | </p> | ||
+ | |||
+ | <span id="MC1.5 Thermal Experimentations"> </span> | ||
+ | <h3>Thermal experimentation</h3> | ||
+ | <hr> | ||
+ | <h4>Simulation Results</h4> | ||
+ | <p> | ||
+ | These are the simulation results for the latest design of the MC1.5. | ||
+ | </p> | ||
+ | |||
+ | <p> | ||
+ | The following figures represent the repartition of heat at | ||
+ | the beginning and the end of a heating speed test: | ||
+ | </p> | ||
+ | <p> <font color="red">MC1.5Heating speed test image</font></p> | ||
+ | <p> | ||
+ | The final temperature has been achieved in <font color="red">70</font> seconds. | ||
+ | </p> | ||
+ | |||
+ | <p> | ||
+ | The following figures represent the repartition of heat at | ||
+ | the beginning and the end of a cooling speed test: | ||
+ | </p> | ||
+ | <p> <font color="red">MC1.5 Cooling speed test image</font></p> | ||
+ | <p> | ||
+ | The final temperature has been achieved in <font color="red">135</font> seconds. | ||
+ | </p> | ||
+ | <a href="#MC1.5">Back to MC1.5</a> | ||
+ | |||
+ | <h4>Trials Results</h4> | ||
+ | |||
+ | <span id="MC1.5 Thermal Experimentations Results"> </span> | ||
+ | <h4>Thermal Experimentations Results</h4> | ||
<ul> | <ul> | ||
− | <li> | + | <li><a href="#MC1.5_Maintain_Cold_results">Maintaining a temperature below room temperature test results</a></li> |
− | <li> | + | <li><a href="#MC1.5_Maintain_Hot_results">Maintaining a temperature over room temperature test results</a></li> |
+ | <li><a href="#MC1.5_to_Cold_results">Cooling speed test results</a></li> | ||
+ | <li><a href="#MC1.5_to_Hot_results">Heating speed test results</a></li> | ||
</ul> | </ul> | ||
+ | <span id="MC1.5_Maintain_Cold_results"> </span> | ||
+ | <h5>Maintaining a temperature below room temperature test results</h5> | ||
+ | <p> | ||
+ | These are the results obtained by following this | ||
+ | <a href="https://2015.igem.org/Team:Sherbrooke/Experiments#MC1.5_Maintain_Cold">protocol</a>. | ||
+ | This table illustrates the relation between the voltages | ||
+ | applied to the Peltier element and the set temperature of the aluminium mold. | ||
+ | </p> | ||
+ | <p> <font color="red">MC1.5 Table Calibration cold</font></p> | ||
+ | <font color="#565656">Conclusion</font> | ||
+ | <ul> | ||
+ | <li>The MC1.5 can reach the client’s low temperature specification of 4℃</li> | ||
+ | <li>The MC1.5 can reach the client’s temperature stability specification of ±1.5℃</li> | ||
+ | </ul> | ||
+ | <span id="MC1.5_Maintain_Hot_results"> </span> | ||
+ | <h5>Maintaining a temperature below room temperature test results</h5> | ||
+ | <p> | ||
+ | These are the results obtained by following this | ||
+ | <a href="https://2015.igem.org/Team:Sherbrooke/Experiments#MC1.5_Maintain_Hot">protocol</a>. | ||
+ | This table illustrates the relation between the voltages | ||
+ | applied to the Peltier element and the set temperature of the aluminium mold. | ||
+ | </p> | ||
+ | <p> <font color="red">MC1.5 Table Calibration HOT</font></p> | ||
+ | <font color="#565656">Conclusion</font> | ||
+ | <ul> | ||
+ | <li>The MC1.5 can reach the client’s high temperature specification of 80℃</li> | ||
+ | <li>The MC1.5 can reach the client’s temperature stability specification of ±1.5℃</li> | ||
+ | </ul> | ||
− | < | + | <span id="MC1.5_to_Cold_results"> </span> |
− | <p> | + | <h5>Cooling speed test results</h5> |
+ | <p> | ||
+ | These are the results obtained by following this | ||
+ | <a href="https://2015.igem.org/Team:Sherbrooke/Experiments#MC1.5_to_Cold">protocol</a>. | ||
+ | This figure shows the aluminium mold’s temperature versus time | ||
+ | for an applied voltage of 15V. | ||
+ | </p> | ||
+ | <p> <font color="red">MC1.5 cooling speed test 15V</font></p> | ||
+ | </p> | ||
+ | This figure shows the aluminium mold’s temperature versus time | ||
+ | for an applied voltage of 15.5V. | ||
+ | </p> | ||
+ | <p> <font color="red">MC1.5 cooling speed test 15.5V</font></p> | ||
+ | </p> | ||
+ | This figure shows the aluminium mold’s temperature versus time | ||
+ | for an applied voltage of 16V. | ||
+ | </p> | ||
+ | <p> <font color="red">MC1.5 cooling speed test 16V</font></p> | ||
+ | <font color="#565656">Conclusion</font> | ||
<ul> | <ul> | ||
− | <li> | + | <li>15.5V is the optimal voltage to apply to obtain the highest cooling speed</li> |
− | <li> | + | <li>The MC1.5 can reach the client’s specification of a cooling speed of 0.5℃/s</li> |
− | + | ||
</ul> | </ul> | ||
− | < | + | <span id="MC1.5_to_Hot_results"> </span> |
+ | <h5>Heating speed test results</h5> | ||
+ | <p> | ||
+ | These are the results obtained by following this | ||
+ | <a href="https://2015.igem.org/Team:Sherbrooke/Experiments#MC1.5_to_Hot">protocol</a>. | ||
+ | This figure shows the aluminium mold’s temperature versus time | ||
+ | for an applied voltage of 24V. | ||
+ | </p> | ||
+ | <p> <font color="red">MC1.5 heating speed test 24V</font></p> | ||
+ | <font color="#565656">Conclusion</font> | ||
<ul> | <ul> | ||
− | + | <li>The MC1.5 can reach the client’s specification of a heating speed of 1℃/s</li> | |
− | + | ||
− | + | ||
</ul> | </ul> | ||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
+ | <span id="Achievements"> </span> | ||
+ | <h2>Achievements<h2> | ||
+ | <hr><hr><hr> | ||
+ | </br> | ||
+ | |||
+ | |||
+ | <span id="Future Plans"> </span> | ||
+ | <h2>Future Plans<h2> | ||
+ | <hr><hr><hr> | ||
+ | </br> | ||
+ | |||
</div> | </div> | ||
</div></div> <!--Closing tag for div id="mainContainer" and div id="contentContainer". Opening tag are in the template--> | </div></div> <!--Closing tag for div id="mainContainer" and div id="contentContainer". Opening tag are in the template--> | ||
</html> | </html> |
Revision as of 22:36, 12 September 2015
Project Results
Overview
Experimentations Results
Project modules
MC96
Project modules
MC96
A thermal experimentation has been the only experimentation done on the MC96 module.
Thermal experimentations
Has no prototype has been built yet, the only results available are the ones from simulations.
Simulation Results
Some simulation has been done on earlier designs, but none of the final design, due to the complexity of simulating heat pipes. Thus, these results are not finals and will surely improve with the addition of the heat pipes between the Peltier elements and the 96-well aluminium mold.
The following figures represent the repartition of heat at the beginning and the end of a heating speed test:
MC96 Heating speed test image
The final temperature has been achieved in 70 seconds.
The following figures represent the repartition of heat at the beginning and the end of a cooling speed test:
MC96 Cooling speed test image
The final temperature has been achieved in 135 seconds.
Back to MC96 Back to Experimentations Results Back to topMC1.5
Thermal and magnetisation experimentations have been conduct to validate the design of the MC1.5 module. These are the results of those experimentations.
Thermal experimentation
Simulation Results
These are the simulation results for the latest design of the MC1.5.
The following figures represent the repartition of heat at the beginning and the end of a heating speed test:
MC1.5Heating speed test image
The final temperature has been achieved in 70 seconds.
The following figures represent the repartition of heat at the beginning and the end of a cooling speed test:
MC1.5 Cooling speed test image
The final temperature has been achieved in 135 seconds.
Back to MC1.5Trials Results
Thermal Experimentations Results
- Maintaining a temperature below room temperature test results
- Maintaining a temperature over room temperature test results
- Cooling speed test results
- Heating speed test results
Maintaining a temperature below room temperature test results
These are the results obtained by following this protocol. This table illustrates the relation between the voltages applied to the Peltier element and the set temperature of the aluminium mold.
MC1.5 Table Calibration cold
Conclusion- The MC1.5 can reach the client’s low temperature specification of 4℃
- The MC1.5 can reach the client’s temperature stability specification of ±1.5℃
Maintaining a temperature below room temperature test results
These are the results obtained by following this protocol. This table illustrates the relation between the voltages applied to the Peltier element and the set temperature of the aluminium mold.
MC1.5 Table Calibration HOT
Conclusion- The MC1.5 can reach the client’s high temperature specification of 80℃
- The MC1.5 can reach the client’s temperature stability specification of ±1.5℃
Cooling speed test results
These are the results obtained by following this protocol. This figure shows the aluminium mold’s temperature versus time for an applied voltage of 15V.
MC1.5 cooling speed test 15V
This figure shows the aluminium mold’s temperature versus time for an applied voltage of 15.5V.MC1.5 cooling speed test 15.5V
This figure shows the aluminium mold’s temperature versus time for an applied voltage of 16V.MC1.5 cooling speed test 16V
Conclusion- 15.5V is the optimal voltage to apply to obtain the highest cooling speed
- The MC1.5 can reach the client’s specification of a cooling speed of 0.5℃/s
Heating speed test results
These are the results obtained by following this protocol. This figure shows the aluminium mold’s temperature versus time for an applied voltage of 24V.
MC1.5 heating speed test 24V
Conclusion- The MC1.5 can reach the client’s specification of a heating speed of 1℃/s