We conducted our experiments by following the protocols below. As an official procedure, lab workers should understand the lab experiment assigned to them along with safety procedures before starting lab work. The protocols are arranged according to the order of experiments we followed.
How to handle reagents.
1.
Reagents used in our project, such as restriction reagents, must be stored in low temperature. The reagents must be stored in the freezer when they are not used, and must be put on ice when taking them out of the freezer for an experiment.
2.
Reagents should be added last to the solution, because reagents are sensitive to inactivation by pH and ionic conditions that deviate from their storage and reaction buffers. After adding reagents, the mixed solution should be mixed completely.
Protocols to store materials and maintain
usage history of each material.
1.
Reporter cell, test cell and competent cell (Top 10 invitrogen) must be kept at 4°C and frequently used reagents, reagents, DNA plasmids should be kept at −20°C in the freezer.
2.
We use triple distilled water (or DDH2O) to make LB broth. Triple distilled water is kept at lab temperature (around 18 °C or lower).
3.
Other materials such as yeast and NaCl are stored and maintained under the responsibility of Gachon Molecular Biology Lab.
4.
We have to record the history of each material, including if plasmids/reporter cell/ test cell/ AHL have been frozen and if so, when it is used.
To The Top
LB Medium
1. To prevent contamination, we only used LB medium made within three days.
2. Materials: Sodium Chloride (LB Media, Sigma), Trypton(LB Media, Sigma), Yeast Extract(LB Media Sigma), ddH2O (triple distilled water)
3. Equipment: autoclave, electronic scale.
4. Protocol For 200mL LB bottle
1) 2 g of Sodium Chloride to a final concentration of 0.17 M
2) 2g of 1%(w/v) Bacto™ tryptone
3) 1g of 0.5% (w/v) yeast extract
4) ddH2O to 200 mL
5) Autoclave for 20 min within 2 hours
6) Keep at room temperature
LB Agar Plates and Addition of Antibiotics
1. We have used LB (solidified lysogeny broth), rich growth medium for E.coli, in our experiments.
2. Just before pouring the solution into petri dishes, an antibiotic can be added for resistance selection. We followed the normal working concentrations such as:
- chloramphenicol: 25 μg/mL (Chloramphenicol stock is dissolved in ethanol) In case of using ampicillin: 100 μg/mL
- normal stock concentrations:1000-fold
3. Material to make LB plates: Sodium Chloride (LB Media, Sigma) Bacto™ tryptone (LB Media, Sigma) yeast extract (LB Media, Sigma) Bacto™ agar (LB Media, Sigma) ddH2O (triple distilled water) 1000x chloramphenicol or ampicillin
4. LB agar preparation protocol We usually make 1liter bottle for LB Agar
1) 200 mL LB prepared fresh, non-autoclaved
2) 3 g agar
3) Shake until all solids are dissolved
4) Autoclave for 20 min within 2 hr
5) Keep it cool until it reaches around 40-50 °C
6) Add 200 μL of 1000x chloramphenicol and gently stir it. Be careful not to shake the bottle too long/hard so that bubbles are created.
7) Pour into empty petri dishes just enough to cover the surface (~20 mL per plate). In case that bubbles are in the plate, heat the plate surface carefully with a burner only until the bubbles are burst but the solution is heated.
8) Leave the plates at room temperature around one hour until it is solidified.
9) Solidified plates should be turned upside down for a few hours at room temperature, then stored at 4°C.
10
Person who leaves the lab last must make sure that power is disconnected, flammable material is isolated, dangerous material is safely kept, water is disconnected, lab is cleaned and locked, and order of the lab must be double- checked.
11
Power wiring appliance must be properly installed to accommodate the experiments. Cables, and lines must be checked regularly to confirm that they are capable of handling the electrical load.
12
All equipment must be connected with the proper power Cable and must not be connected in a multiple power socket.
13
Autoclave for 20 min within 2 hr
14
Keep it cool until it reaches
around 40-50 °C
15
Add 200 μL of 1000x chloramphenicol
and gently stir it. Be careful not
to shake the bottle too long/hard so that
bubbles are created.
16
Pour into empty petri dishes
just enough to cover the surface
(~20 mL per plate).
In case that bubbles are in
the plate, heat the plate surface
carefully with a burner only
until the bubbles are
burst but the solution is heated.
17
Leave the plates at room
temperature around one hour
until it is solidified.
18
Solidified plates should be
turned upside down for a
few hours at room temperature,
then stored at 4°C.
19
Inflammable chemicals including acetone, oil, or gas must be kept in the place where ventilation is easy and access is infrequent.
20
Importing and exporting of high-pressure gas container must be done using transportation equipment.
21
When storing high-pressure gas containers, they must be safely and firmly fixed, isolated from flammable substances and inflammatory materials.
21
Experiments using flammable, explosive, toxic, or volatile gases or vapors must be carried out in a hood.
22
Reagents container or cabinets for storing reagents must be kept in cool, well-ventilated places without direct sunlight, and far away from fire and heat sources.
23
Experimental drugs shall be stored in a way not to be shaken by outside shock, and so that its storage bottles do not fall
24
Toxic materials shall be handled using protective films, or other safety tents to prevent damages from splatter, heating or explosion so as to ensure the safety of the experimenter.
25
Containers for chemical wastes shall not be left in the hallway or on the stairs, and shall not be stored in the corners of the laboratory or other invisible places.
26
When performing microbiological tests, gloves shall be worn, and after the experiment, the used glassware shall be
washed through sterilization, and disposable supplies and medium shall be disposed of separately from general garbage.
27
Inflammable chemicals including acetone, oil, or gas must be kept in the place where ventilation is easy and access is infrequent.
28
Importing and exporting of high-pressure gas container must be done using transportation equipment.
29
When storing high-pressure gas containers, they must be safely and firmly fixed, isolated from flammable substances and inflammatory materials.
Other significant Safety Considerations.
1. Fire Regulations.
When fire breaks out, the following guidelines shall apply.
2)
Call the fire brigade.
3)
Alert people in the area.
4)
Extinguish the fire if possible.
5)
Close doors to the area.
7)
Reassemble outside the building at the designated meeting point.
Also it is very important to know the locations of the fire-fighting equipment, fire alarms, and evacuation routes closest to the lab.
A small fire can be extinguished quickly by smothering it in a fire blanket or by spraying it with a fire extinguisher.
Lab fires in biological labs are caused most commonly by the plating of cell cultures.
To prevent this,
1
Never use paper bench coat near burners.
2
Use a low reservoir volume of ethanol.
3
Place the ethanol reservoir at least a foot from the burner and on the opposite side of the burner from the plates
4
Never wear plastic gloves when working with a flame.
5
Carry the gas container for the burner carefully with a firm grip. If it is dropped, make sure that there is no leakage by smelling for gas.
6
Notify the instructor of any gas leakage and do not light burners when there is a smell of gas.
7
Always light the match before opening the gas valve.
8
Avoid placing burners too close to overhanging shelves.
9
Never leave the table while a burner is on.
CHEMICALS
On each chemical container, there is a label that specifies the potential danger of the substance for humans and/or the environment.
Chemicals should be handled cautiously with gloves, both for your safety and for decreasing the contamination risk.
Always wear a lab coat and shoes as additional protection. Read the signs on the chemical container and the Material Safety Data Sheet
(MSDS; available online) for further direction.
BIO- SAFETY AND DISPOSAL
When you are working to generate new organisms by molecular methods, you are regulated in most countries
according to international biosafety guidelines:
4
Institutional Bio-safety Committee, under the ministry of Health and Welfare, Korea Center for Disease Control & Prevention.
http://biosafety.cdc.go.kr
When working with microorganisms such as bacteria and viruses, there are four BioSafety Levels (BSL) numbered BSL1–4.
Biosafety level is the level of the biocontainment precautions required to isolate dangerous biological agents in an enclosed
The levels of containment range from the lowest biosafety level 1 to the highest at level 4, and Ministry of Health and Welfare and Korea Centers
for Disease Control and Prevention have specified these levels facility.
Biocontainment can be classified by the relative danger to the surrounding environment as biological
safety levels. As of 2006, there are four safety levels. These are called BSL1 through BSL4
BSL 1
1
involving well-characterized agents not known to consistently cause disease in healthy adult humans and of minimal potential hazard to laboratory personnel and the environment.
2
bacteria and viruses including canine hepatitis, non-pathogenic Escherichia coli, as well as cell cultures and non-infectious bacteria.
3
The laboratory is not necessarily separated from the general traffic patterns in the building.
4
Conducted on open bench tops using standard microbiological practices.
5
Laboratory personnel have specific training in the procedures conducted in the laboratory.
6
Supervised by a scientist with proper training.
7
Contaminated materials are left in open waste receptacles.
BSL 2
1
Similar to Biosafety Level 1 and is suitable for work involving agents of moderate potential hazard to personnel and the environment.
2
Includes various bacteria and viruses that cause only mild disease to humans, or are difficult to contract via aerosol in a lab setting such as C. difficile, most Chalmydiae, hepatitis A,B, and C, orthopoxviruses, influenza A, Lyme disease, Salmonella, mumps, measles, scapie, MRSA, and VRSA.
3
similar to Biosafety Level 1 and is suitable for work involving agents of moderate potential hazard to personnel and the environment. It includes various bacteria and viruses that cause only mild disease to humans, or are difficult to contract via aerosol in a lab setting.
4
Laboratory personnel have specific training in handling pathogenic agents,
5
Must be directed by scientists with advanced training.
6
Extreme precautions are taken with contaminated sharp items.
7
In case that infectious aerosols or splashes may be created, specified procedures should be conducted in biological safety cabinets or other physical containment equipment.
BSL 3
1
Indigenous or exotic agents which may cause serious or potentially lethal disease after inhalation.
2
Includes various bacteria, parasites and viruses that can cause severe to fatal disease in humans but for which treatments exist, such as Yersinia pestis, SARS coronavirus, Brucella, yellow fever virus.
3
Laboratory personnel have specific training in handling pathogenic and potentially lethal agents,
4
Supervised by competent scientists who are experienced in working with these agents.
5
All procedures involving the manipulation of infectious materials are conducted within biological safety cabinets, specially designed hoods, or other physical containment devices.
6
The laboratory personals should wear appropriate personal protective clothing and equipment.
7
An acceptable level of safety for the conduct of routine procedures, may be achieved in a biosafety level 2 facility, providing the filtered exhaust air from the laboratory room is discharged to the outdoors.
8
The ventilation to the laboratory is balanced to provide directional airflow into the room.
9
Access to the laboratory is restricted when work is in progress and the recommended Standard Microbiological Practices, Special Practices, and Safety Equipment for Biosafety Level 3 are rigorously followed.
BSL 4
1
Limited access only for authorized persons can work in the facilities. Not allowed for people who have weak immune system.
2
When dealing with biological hazards at this level, the use of a positive pressure personnel suit, with a segregated mandatory.
3
All works should be supervised by qualified scientists who are trained and experienced in working with these agents.
4
The entrance and exit of a level 4 bio-lab will contain multiple showers, a vacuum room, an ultraviolet light room, and other safety precautions designated to destroy all traces of the biohazard.
5
Multiple airlocks are employed and are electronically secured to prevent both doors from opening at the same time.
6
All air and water service going to and coming from a biosafety level 4 will undergo similar decontamination procedures to eliminate the possibility of an accidental release.
7
Members of the laboratory staff shall have specific and thorough training in handling extremely hazardous infectious agents, and they shall understand the primary and secondary containment functions of the standard and special practices, the containment equipment, and the laboratory design characteristics.