Difference between revisions of "Team:Gifu/InterLab"
(24 intermediate revisions by the same user not shown) | |||
Line 71: | Line 71: | ||
<center><font size="20" face="Century">Inter Lab Study</font></center><br><br> | <center><font size="20" face="Century">Inter Lab Study</font></center><br><br> | ||
− | <font size="6" face=" | + | <font size="6" face="Century">Equipment</font> |
<hr width="100%" ><br> | <hr width="100%" ><br> | ||
<ul> | <ul> | ||
<li> <font size="5" face="Arimo"> BioSHAKER TA-12R<br></font> </li> | <li> <font size="5" face="Arimo"> BioSHAKER TA-12R<br></font> </li> | ||
− | <font size="4" face=" | + | <font size="4" face="Century"> |
use for shaking culture</font> | use for shaking culture</font> | ||
<br><br><br><br> | <br><br><br><br> | ||
− | <li> <font size="5" face=" | + | <li> <font size="5" face="Century"> Safire ART-NR:F129013<br></font> </li> |
− | <font size="4" face=" | + | <font size="4" face="Century"> |
use for measurement of absorbance</font> | use for measurement of absorbance</font> | ||
<br><br><br><br><br> | <br><br><br><br><br> | ||
</ul> | </ul> | ||
− | <font size="6" face=" | + | <font size="6" face="Century">Method of Measurement</font> |
− | <hr width="100%" > | + | <hr width="100%" ><br> |
<ul> | <ul> | ||
− | <font size="4" face=" | + | <font size="4" face="Century"> |
− | We constructed 5 plasmids [positive control, negative control, | + | <p> We constructed 5 plasmids [positive control, negative control, generator 1~3] by using BioBricks and then transformed to <i>E. coli</i> K-12 JM109. We checked them by colony direct PCR and plasmids sequence. We cultivated correct bacterias by shaking until OD660:0.5. Cultivated mediums were transferred to 96-well plate by 100mL. We read the absorbance.</p> |
<br> | <br> | ||
Setting of plate reader is following:<br></font> | Setting of plate reader is following:<br></font> | ||
Line 95: | Line 95: | ||
</ul> | </ul> | ||
− | <font size="6" face=" | + | <font size="6" face="Century">Result</font> |
<hr width="100%" ><br> | <hr width="100%" ><br> | ||
<ul> | <ul> | ||
− | <li> <font size="5" face=" | + | <li> <font size="5" face="Century"> Definition<br></font> </li> |
− | <font size="4" face=" | + | <font size="4" face="Century"> |
− | We expressed absorbance as relative value for positive control. <br>This expression is following:<br></font> | + | <p> We expressed absorbance as relative value for positive control. <br>This expression is following:<br></p></font> |
<img src="https://static.igem.org/mediawiki/2015/8/85/Siki-gifu.png" border="0" width="211" height="57"><br> | <img src="https://static.igem.org/mediawiki/2015/8/85/Siki-gifu.png" border="0" width="211" height="57"><br> | ||
Sample : Absorbance in sample<br> | Sample : Absorbance in sample<br> | ||
Line 107: | Line 107: | ||
<br><br><br> | <br><br><br> | ||
− | <li> <font size="5" face=" | + | <li> <font size="5" face="Century"> Value<br></font> </li> |
− | <font size="4" face=" | + | <font size="4" face="Century"> |
− | Relative absorbance values for positive control are shown below. <br> | + | <p>Relative absorbance values for positive control are shown below. <br></p> |
<img src="https://static.igem.org/mediawiki/2015/e/e4/GURAHU-gifu.png" border="0" width="572" height="364"> <br><br> | <img src="https://static.igem.org/mediawiki/2015/e/e4/GURAHU-gifu.png" border="0" width="572" height="364"> <br><br> | ||
− | + | FIG1 Relative absorbance values <br></font> | |
− | + | 20K : generator 1 (J23101 + I13504)<br> | |
+ | 22A : generator 2 (J23106 + I13504)<br> | ||
+ | 22K : generator 3 (J23117 + I13504)<br><br><br> | ||
</ul> | </ul> | ||
<br><br> | <br><br> | ||
+ | <font size="6" face="Century">Discussion</font> | ||
+ | <hr width="100%" ><br> | ||
+ | <ul> | ||
+ | <font size="4" face="Century"> | ||
+ | <p> The value of device1 is much higher than that of device2 and 3. This is why each device is different from promoter sequence, especially -10 and -35 region.<br><br></p> | ||
+ | <img src="https://static.igem.org/mediawiki/2015/b/b4/Konnsennsasu2.png" border="0" width="413" height="105"> <br><br> | ||
+ | <p>Promoter sequence in device1 resembles consensus sequence. On the other hand, device2 and 3 is not similar than device1. This is how each GFP expression is different.</p> | ||
+ | <br><br><br> | ||
+ | </font> | ||
+ | </ul> | ||
+ | <br><br> | ||
<br><br></font> | <br><br></font> | ||
Line 129: | Line 142: | ||
<ol id="index"> | <ol id="index"> | ||
<li><a href="https://2015.igem.org/Team:Gifu/InterLab" style="text-decoration:none;" style="text-decoration:none;" >InterLab Study </a></li> | <li><a href="https://2015.igem.org/Team:Gifu/InterLab" style="text-decoration:none;" style="text-decoration:none;" >InterLab Study </a></li> | ||
− | <li><a href=" | + | <li><a href="https://2015.igem.org/Team:Gifu/Safety"style="text-decoration:none;" > SAFETY </a></li> |
− | + | <li><a href="https://2015.igem.org/Team:Gifu/human-practice" style="text-decoration:none;" >Policy & Practice </a></li> | |
− | + | ||
− | <li><a href=" | + | <br> |
− | + | ||
− | + | ||
− | + | ||
− | + | ||
</ol> | </ol> | ||
Latest revision as of 08:15, 18 September 2015