Difference between revisions of "Team:Bielefeld-CeBiTec/Design"
Line 128: | Line 128: | ||
<p> So far so good. Fluorescence imaging of liquids in quite high amounts is possible. But does it also works with small volumes and on paper? Therefore we took normal laboratory filter papers. (MN 827 B from Macherey and Nagel, C 350 L and FN3 from Munktell and a laboratory filter paper we got from Merck) and put the lysates on the paper and took the photos. Exemplary the results from laboratory filter paper from Merck are shown. The other ones showed the same results. As you can see in the picture below this paragraph, it is possible to photograph volumes of 5 µl purified GFP up to a concentration of 17,5 mmol/L. </p> | <p> So far so good. Fluorescence imaging of liquids in quite high amounts is possible. But does it also works with small volumes and on paper? Therefore we took normal laboratory filter papers. (MN 827 B from Macherey and Nagel, C 350 L and FN3 from Munktell and a laboratory filter paper we got from Merck) and put the lysates on the paper and took the photos. Exemplary the results from laboratory filter paper from Merck are shown. The other ones showed the same results. As you can see in the picture below this paragraph, it is possible to photograph volumes of 5 µl purified GFP up to a concentration of 17,5 mmol/L. </p> | ||
− | |||
− | <figure style="margin:auto; width: | + | <div class="row"> |
+ | <div class="col-md-6 text-center" style="margin-bottom: 20px"> | ||
+ | <figure style="margin:auto; width: 350px"> | ||
<a href="https://static.igem.org/mediawiki/2015/d/d7/Bielefeld-CeBiTec_test_on_paper.png" data-lightbox="detection" data-title="We added a small amount of lysate to the scrap of paper and photographed it with the different filter combinations. The top photo is whithout any filter. The picture in the middle was taken with the filter combination for sfGFP and for the bottom picture the mRFP filters were used."><img src="https://static.igem.org/mediawiki/2015/d/d7/Bielefeld-CeBiTec_test_on_paper.png" ></a> | <a href="https://static.igem.org/mediawiki/2015/d/d7/Bielefeld-CeBiTec_test_on_paper.png" data-lightbox="detection" data-title="We added a small amount of lysate to the scrap of paper and photographed it with the different filter combinations. The top photo is whithout any filter. The picture in the middle was taken with the filter combination for sfGFP and for the bottom picture the mRFP filters were used."><img src="https://static.igem.org/mediawiki/2015/d/d7/Bielefeld-CeBiTec_test_on_paper.png" ></a> | ||
<figcaption> We added a small amount of lysate to the scrap of paper and photographed it with the different filter combinations. The top photo is whithout any filter. The picture in the middle was taken with the filter combination for sfGFP and for the bottom picture the mRFP filters were used. | <figcaption> We added a small amount of lysate to the scrap of paper and photographed it with the different filter combinations. The top photo is whithout any filter. The picture in the middle was taken with the filter combination for sfGFP and for the bottom picture the mRFP filters were used. | ||
</figcaption> | </figcaption> | ||
</figure> | </figure> | ||
+ | </div> | ||
+ | <div class="col-md-6 text-center" style="margin-bottom: 20px"> | ||
+ | <br> | ||
+ | <br> | ||
<br> | <br> | ||
− | |||
<p> Now we wanted to find out if it is possible to photograph the fluorescence from a CFPS experiment on paper. So after a CFPS run on paper, we took the scrap of paper and took a photo from it. As you can see in the picture below. </p> | <p> Now we wanted to find out if it is possible to photograph the fluorescence from a CFPS experiment on paper. So after a CFPS run on paper, we took the scrap of paper and took a photo from it. As you can see in the picture below. </p> | ||
<br> | <br> | ||
− | <figure style="margin:auto; width: | + | <figure style="margin:auto; width: 400px"> |
<a href="https://static.igem.org/mediawiki/2015/9/99/Bielefeld-CeBiTec_CFPS_on_Paper.png" data-lightbox="detection" data-title="We took the scrap of paper from the CFPS an took an photo. And as you can see in the picture it worked. We can take an photo of the sfGFP generated in the CFPS."><img src="https://static.igem.org/mediawiki/2015/9/99/Bielefeld-CeBiTec_CFPS_on_Paper.png" ></a> | <a href="https://static.igem.org/mediawiki/2015/9/99/Bielefeld-CeBiTec_CFPS_on_Paper.png" data-lightbox="detection" data-title="We took the scrap of paper from the CFPS an took an photo. And as you can see in the picture it worked. We can take an photo of the sfGFP generated in the CFPS."><img src="https://static.igem.org/mediawiki/2015/9/99/Bielefeld-CeBiTec_CFPS_on_Paper.png" ></a> | ||
<figcaption> We took the scrap of paper from the CFPS an took an photo. And as you can see in the picture it worked. We can take an photo of the sfGFP generated in the CFPS. | <figcaption> We took the scrap of paper from the CFPS an took an photo. And as you can see in the picture it worked. We can take an photo of the sfGFP generated in the CFPS. | ||
Line 148: | Line 152: | ||
</figure> | </figure> | ||
+ | </div> | ||
</div> | </div> | ||
<br> | <br> | ||
− | + | ||
Line 161: | Line 166: | ||
For easy handling a correct positioning of the smartphone and the biosensor test strip, we designed and printed a measurement case. | For easy handling a correct positioning of the smartphone and the biosensor test strip, we designed and printed a measurement case. | ||
+ | <br> | ||
</p></div> | </p></div> | ||
Line 196: | Line 202: | ||
</div> | </div> | ||
− | + | <div class="The 3D print"> | |
<h2> The 3D print </h2> | <h2> The 3D print </h2> | ||
<p> Ok, the fluorescence detections works fine, but it's not really practical to take the photo. The filter have to be in the right position direct in front of the camera respectively of the flash. Also it has to be quite dark for high quality pictures. Therefore we designed a box and realized it with a 3D printer. The top can be changed specific for the smartphone you use. The test stripe can be placed on the push loading drawer and inserted into the box. So it's quite easy to use. You just have to put the smartphone on the top, insert the test strip an take the photo. </p> | <p> Ok, the fluorescence detections works fine, but it's not really practical to take the photo. The filter have to be in the right position direct in front of the camera respectively of the flash. Also it has to be quite dark for high quality pictures. Therefore we designed a box and realized it with a 3D printer. The top can be changed specific for the smartphone you use. The test stripe can be placed on the push loading drawer and inserted into the box. So it's quite easy to use. You just have to put the smartphone on the top, insert the test strip an take the photo. </p> |
Revision as of 17:19, 18 September 2015
Output Signal processing
A Prototyp for easy fluorescence detection
The problem
We planed to design a practical test strip using fluorescence as output signal. Green fluorescent protein (GFP) is among the most frequently used reporter proteins and has been used in numerous iGEM projects. But detecting fluorescence outside the lab sounded impractical to us. So we had to find an easy way to analyze the output.
The first steps
Before testing we decided to measure the extinction and emission spectra from sfGFP as a basis to choose the most promising filter combination and to have a look if the smartphone flash really excites sfGFP.
In the beginning of our project, we wanted to test if it could work to photograph fluorescence with a smartphone. We got a filter from light engineering from the women cultural center Bielefeld e.V. ("Frauenkulturzentrum Bielefeld e.V.") and put it in front of the smartphone. In the picture below, we took a picture with these filter from purified GFP, sfGFP lysate and lysate without sfGFP. You can see different colors and a different brightnesses in the picture. So in our first impression we thought it's worth to try some other filters, to find the perfect filter for sfGFP imaging with almost no background signal.
Therefore we bought a lee color filter catalog and began to test different filter combinations. The preselection was possible, because we had access to the light transmitting spectra of almost every filter.
The next step was to create a dark environment. Therefore we did handicrafts to design a "black box". Now it was possible to take photos under defined conditions and constant dark background.
The filter combinations
The essential requirements for taking comparable photos are done. Now we had to find the ideal filter combination. So we made a lot of photos with the preselection. We tested 6 filters for emission and combined every filter for emission with up to 16 filters for extinction.After analyzing the photos with the image processing software Fiji, the optimal filter combination found was tokyo blue (071) in front of the flash and twickenham green (736) in front of the camera.
As you can see in the picture above it is really important to choose the right filters to get a high fluorescence signal and a low background signal. But is it only possible to photograph sfGFP and GFP? To find it out, we tried to photograph monomeric red fluorescent protein (mRFP) lysate, as well.
Does fluorescence photography work on Paper?
So far so good. Fluorescence imaging of liquids in quite high amounts is possible. But does it also works with small volumes and on paper? Therefore we took normal laboratory filter papers. (MN 827 B from Macherey and Nagel, C 350 L and FN3 from Munktell and a laboratory filter paper we got from Merck) and put the lysates on the paper and took the photos. Exemplary the results from laboratory filter paper from Merck are shown. The other ones showed the same results. As you can see in the picture below this paragraph, it is possible to photograph volumes of 5 µl purified GFP up to a concentration of 17,5 mmol/L.
Now we wanted to find out if it is possible to photograph the fluorescence from a CFPS experiment on paper. So after a CFPS run on paper, we took the scrap of paper and took a photo from it. As you can see in the picture below.
The App
Now it's possible to photograph fluorescence, but sometimes it's difficult to see the differences. And analyzing the pictures with the image processing software Fiji requires know-how of the user. On the one hand for the program and on the other hand for interpreting the results. We solved this problem with a smartphone App. We coded the App with Android Studio 1.2.2 and can be installed on smartphones on Android 4.2 (Jelly bean) and later. The App determines the median of the greenvalue of a area of pixels in the sensorspot and compares it to the pixels of the negative control (the not induced sensor). If the ratio of a sample and the negative control is above a certain theshold (10%), valid biosensor signal is detected. Additionally it is checked whether the value for the positive control (drop of sfGFP) is above a certain value, thereby confirming the functionality of the biosensor. Furthermore the App displays specific information regarding the different heavymetals and date rape drugs to inform the user. You can download it by clicking on the button below. You need to unzip the file on your phone, since one cannot upload .apk files. Alternatively download it here and delete the fileextension ".txt".
The 3D print
Ok, the fluorescence detections works fine, but it's not really practical to take the photo. The filter have to be in the right position direct in front of the camera respectively of the flash. Also it has to be quite dark for high quality pictures. Therefore we designed a box and realized it with a 3D printer. The top can be changed specific for the smartphone you use. The test stripe can be placed on the push loading drawer and inserted into the box. So it's quite easy to use. You just have to put the smartphone on the top, insert the test strip an take the photo.