Difference between revisions of "Team:Gifu/More/"
(37 intermediate revisions by 3 users not shown) | |||
Line 24: | Line 24: | ||
div.box1 { /MENU/ | div.box1 { /MENU/ | ||
width:100%; | width:100%; | ||
− | + | filter:Alpha(opacity=85);/* IE用 */ | |
+ | opacity:0.85;/* FireFox、Chrome、Opera、Safari用 */ | ||
box-shadow:0px 0px 10px; | box-shadow:0px 0px 10px; | ||
border:1px solid #000; | border:1px solid #000; | ||
− | background-color: # | + | background-color: #ffffaa; |
− | position: | + | position: fixed; |
− | top: | + | top: 100px; |
− | left: | + | left: 10px; |
} | } | ||
Line 68: | Line 69: | ||
<div id="main"> | <div id="main"> | ||
<blockquote> | <blockquote> | ||
− | <center><font size="20" face="Century"> | + | <center><font size="20" face="Century">InterLab Study</font></center><br><br> |
+ | |||
+ | <font size="6" face="Century">Equipment</font> | ||
+ | <hr width="100%" ><br> | ||
+ | <ul> | ||
+ | <li> <font size="5" face="Arimo"> BioSHAKER TA-12R<br></font> </li> | ||
+ | <font size="4" face="Century"> | ||
+ | use for shaking culture</font> | ||
+ | <br><br><br><br> | ||
+ | <li> <font size="5" face="Century"> Safire ART-NR:F129013<br></font> </li> | ||
+ | <font size="4" face="Century"> | ||
+ | use for measurement of absorbance</font> | ||
+ | <br><br><br><br><br> | ||
+ | </ul> | ||
+ | |||
+ | <font size="6" face="Century">Method of Measurement</font> | ||
+ | <hr width="100%" ><br> | ||
+ | <ul> | ||
+ | <font size="4" face="Century"> | ||
+ | <p> We constructed 5 plasmids [positive control, negative control, device1~3] by using BioBricks and then transformed to <i>E. coli</i> K-12 JM109. We checked them by colony direct PCR and plasmids sequence. We cultivated correct bacterias by shaking until OD660:0.5. Cultivated mediums were transferred to 96-well plate by 100mL. We read the absorbance.</p> | ||
+ | <br> | ||
+ | Setting of plate reader is following:<br> | ||
+ | <img src="https://static.igem.org/mediawiki/2015/2/20/Set_safari_gify.png" border="0" width="395" height="220"> | ||
+ | <br><br><br><br> | ||
+ | <b>Sequence data</b><br> | ||
+ | <br> | ||
+ | ・device 1 : J23101+ I13504<br> | ||
+ | <img src="https://static.igem.org/mediawiki/2015/6/6b/Sequence_data1.png" width="800"><br><br> | ||
+ | <br> | ||
+ | ・device 2 : J23106+ I13504<br> | ||
+ | <img src="https://static.igem.org/mediawiki/2015/6/60/Sequence_data2.png" width="800"><br><br> | ||
+ | <br> | ||
+ | ・device 3 : J23117+ I13504<br> | ||
+ | <img src="https://static.igem.org/mediawiki/2015/c/c7/Sequence_data3.png" width="800"><br><br> | ||
+ | |||
+ | <br>These sequence datas are correct.<br></font> | ||
+ | </ul> | ||
+ | <br><br> | ||
+ | <font size="6" face="Century">Result</font> | ||
+ | <hr width="100%" ><br> | ||
+ | <ul> | ||
+ | <li> <font size="5" face="Century"> Definition<br></font> </li> | ||
+ | <font size="4" face="Century"> | ||
+ | <p> We expressed absorbance as relative value for positive control. <br>This expression is following:<br></p></font> | ||
+ | <img src="https://static.igem.org/mediawiki/2015/8/85/Siki-gifu.png" border="0" width="211" height="57"><br> | ||
+ | Sample : Absorbance in sample<br> | ||
+ | NCav : Average of absorbance in negative control<br> | ||
+ | PCav : Average of absorbance in positive control<br> | ||
+ | <br> | ||
+ | <br> | ||
+ | <img src="https://static.igem.org/mediawiki/2015/a/a7/Interlab_data.jpg" width="830"><br><br><br><br> | ||
+ | |||
+ | <li> <font size="5" face="Century"> Value<br></font> </li> | ||
+ | <font size="4" face="Century"> | ||
+ | <p>Relative absorbance values for positive control are shown below. <br></p> | ||
+ | <br> | ||
+ | <br><img src="https://static.igem.org/mediawiki/2015/d/de/Interlab_relative.jpg" width="350"></img><br> | ||
+ | <br> | ||
+ | <br> | ||
+ | <img src="https://static.igem.org/mediawiki/2015/e/e4/GURAHU-gifu.png" border="0" width="572" height="364"> <br><br> | ||
+ | FIG1 Relative absorbance values <br></font> | ||
+ | 20K : Device1 (J23101 + I13504)<br> | ||
+ | 22A : Device2 (J23106 + I13504)<br> | ||
+ | 22K : Device3 (J23117 + I13504)<br><br><br> | ||
+ | |||
+ | |||
+ | </ul> | ||
+ | <br><br> | ||
+ | <font size="6" face="Century">Discussion</font> | ||
+ | <hr width="100%" ><br> | ||
+ | <ul> | ||
+ | <font size="4" face="Century"> | ||
+ | <p> The value of device1 is much higher than that of device2 and 3. This is why each device is different from promoter sequence, especially -10 and -35 region.<br><br></p> | ||
+ | <img src="https://static.igem.org/mediawiki/2015/b/b4/Konnsennsasu2.png" border="0" width="413" height="105"> <br><br> | ||
+ | <p>Promoter sequence in device1 resembles consensus sequence. On the other hand, device2 and 3 is not similar than device1. This is how each GFP expression is different.</p> | ||
+ | |||
+ | <br><br><br> | ||
+ | </font> | ||
+ | </ul> | ||
+ | <br><br> | ||
+ | <br><br></font> | ||
+ | |||
+ | <br><br> | ||
+ | |||
<br><br> | <br><br> | ||
Line 77: | Line 161: | ||
<div class="box1"><br> MENU<br> | <div class="box1"><br> MENU<br> | ||
<ol id="index"> | <ol id="index"> | ||
− | <li><a href=" | + | <li><a href="https://2015.igem.org/Team:Gifu/InterLab" style="text-decoration:none;" style="text-decoration:none;" >InterLab Study </a></li> |
− | + | <li><a href="https://2015.igem.org/Team:Gifu/Safety"style="text-decoration:none;" > SAFETY </a></li> | |
− | + | <li><a href="https://2015.igem.org/Team:Gifu/human-practice" style="text-decoration:none;" >Policy & Practice </a></li> | |
− | + | ||
− | + | <br> | |
− | <li><a href=" | + | |
− | + | ||
− | <li><a href=" | + | |
− | + | ||
</ol> | </ol> | ||
Latest revision as of 17:26, 18 September 2015