Difference between revisions of "Team:HZAU-China/InterLab"
Line 311: | Line 311: | ||
<div class="maincontent"> | <div class="maincontent"> | ||
<h1></br></br></br>Overview</h1></br> | <h1></br></br></br>Overview</h1></br> | ||
− | <p> | + | <p>This year, we are not only in general event but also participate in Measurement Interlab. All the iGEM teams that are in this Interlab Study should collect fluorescence intensity data of three specific genetic devices which is the same with others and can express GFP protein.</p> |
</br><p>The three genetic devices differ in their promotors :</p> | </br><p>The three genetic devices differ in their promotors :</p> | ||
− | <p><strong>Device 1: J23101 + I13504 (B0034-E0040-B0015), | + | <p><strong>Device 1: J23101 + I13504 (B0034-E0040-B0015), in the pSB1C3 backbone</strong></p> |
− | <p><strong>Device 2: J23106 + I13504 (B0034-E0040-B0015), | + | <p><strong>Device 2: J23106 + I13504 (B0034-E0040-B0015), in the pSB1C3 backbone</strong></p> |
− | <p><strong>Device 3: J23117 + I13504 (B0034-E0040-B0015), | + | <p><strong>Device 3: J23117 + I13504 (B0034-E0040-B0015), in the pSB1C3 backbone</strong></p></br> |
− | <p> | + | <p>Firstly, we transformed these three devices into competent cells (DH 5 alpha) respectively. And then, We did pre-experiment before formal experiment to confirm the suitable period as well as the dilution factor. What’s more, their fluorescence intensity is measured with a plate reader in suitable optical density of the LB medium. We assumed that the GFP expression quality of them ordered from high to low would be Device 1, Device 2, Device 3. Finally, the result confirmed our conjecture.</p> |
</br></br> | </br></br> | ||
</div><!--maincontent结束--> | </div><!--maincontent结束--> |
Revision as of 02:49, 16 September 2015
Mixed-Reality Cell
Bidirectinal coupling between real and virtual bio-oscillator
Overview
This year, we are not only in general event but also participate in Measurement Interlab. All the iGEM teams that are in this Interlab Study should collect fluorescence intensity data of three specific genetic devices which is the same with others and can express GFP protein.
The three genetic devices differ in their promotors :
Device 1: J23101 + I13504 (B0034-E0040-B0015), in the pSB1C3 backbone
Device 2: J23106 + I13504 (B0034-E0040-B0015), in the pSB1C3 backbone
Device 3: J23117 + I13504 (B0034-E0040-B0015), in the pSB1C3 backbone
Firstly, we transformed these three devices into competent cells (DH 5 alpha) respectively. And then, We did pre-experiment before formal experiment to confirm the suitable period as well as the dilution factor. What’s more, their fluorescence intensity is measured with a plate reader in suitable optical density of the LB medium. We assumed that the GFP expression quality of them ordered from high to low would be Device 1, Device 2, Device 3. Finally, the result confirmed our conjecture.
© 2015 Huazhong Agricultural University iGEM Team. All rights reserved.
Contacts
- No.1, Shizishan Street, Hongshan District 430070,P.R.China
- Email:hzauigem@gmail.com
- Twitter : hzau_igem
- Wechat : hzauigem
- QQ Group : 313297095
- YouTube : hzauigem