Difference between revisions of "Team:Bielefeld-CeBiTec/Results/HeavyMetals"

Line 24: Line 24:
 
      
 
      
 
      
 
      
 +
 +
 
<figure style="width: 600px">
 
<figure style="width: 600px">
 
<a href="https://static.igem.org/mediawiki/2015/1/1c/Bielefeld-CeBiTec_Arsenic_invivo_large.png" data-lightbox="heavymetals" data-title="Time course of the induction of an arsenic biosensor with RFP for different arsenic concentrations <i>in vivo</i>. Error bars represent the standard deviation of three biological replicates."><img src="https://static.igem.org/mediawiki/2015/2/2e/Bielefeld-CeBiTec_Arsenic_invivo_small.png" alt="Adjusting the detection limit"></a>
 
<a href="https://static.igem.org/mediawiki/2015/1/1c/Bielefeld-CeBiTec_Arsenic_invivo_large.png" data-lightbox="heavymetals" data-title="Time course of the induction of an arsenic biosensor with RFP for different arsenic concentrations <i>in vivo</i>. Error bars represent the standard deviation of three biological replicates."><img src="https://static.igem.org/mediawiki/2015/2/2e/Bielefeld-CeBiTec_Arsenic_invivo_small.png" alt="Adjusting the detection limit"></a>
 
<figcaption>Time course of the induction of an arsenic biosensor with RFP for different arsenic concentrations in vivo. Error bars represent the standard deviation of three biological replicates.</figcaption>
 
<figcaption>Time course of the induction of an arsenic biosensor with RFP for different arsenic concentrations in vivo. Error bars represent the standard deviation of three biological replicates.</figcaption>
 
</figure>
 
</figure>
 
+
   
 
+
<figure style="width: 600px">
 +
<a href="https://static.igem.org/mediawiki/2015/7/7d/Bielefeld-CeBiTec_heavy_metal_influence_growth.jpeg" data-lightbox="heavymetals" data-title=" Influence of heavy metals on the growth of <i>E.coli KRX</i> shown is the standard deviation of three biological replicates. For induction concentrations of
 +
20 µg/L lead, 60 µg/L mercury, 60 µg/L chromium, 80 µg/L nickel, 40 mg/L copper which represent ten times of the WHO guideline were used."><img src="https://static.igem.org/mediawiki/2015/7/7d/Bielefeld-CeBiTec_heavy_metal_influence_growth.jpeg" alt="Adjusting the detection limit"></a>
 +
<figcaption>Influence of heavy metals on the growth of <i>E.coli KRX</i> shown is the standard deviation of three biological replicates. For induction concentrations of
 +
20 µg/L lead, 60 µg/L mercury, 60 µg/L chromium, 80 µg/L nickel, 40 mg/L copper which represent ten times of the WHO guideline were used.
 +
</figcaption>
 +
</figure>
 
      
 
      
 
</div>
 
</div>

Revision as of 23:44, 13 September 2015

iGEM Bielefeld 2015


Heavy Metals

Zusammenfassung in ganz wenigen Worten.

Adjusting the detection limit
Time course of the induction of an arsenic biosensor with RFP for different arsenic concentrations in vivo. Error bars represent the standard deviation of three biological replicates.
Adjusting the detection limit
Influence of heavy metals on the growth of E.coli KRX shown is the standard deviation of three biological replicates. For induction concentrations of 20 µg/L lead, 60 µg/L mercury, 60 µg/L chromium, 80 µg/L nickel, 40 mg/L copper which represent ten times of the WHO guideline were used.