Difference between revisions of "Team:Tokyo Tech/Experiment/C4HSL-dependent growth assay"

Line 268: Line 268:
 
&nbsp;&nbsp;&nbsp;Yuta Yamazaki : Measured the devices and processed the data.<br>
 
&nbsp;&nbsp;&nbsp;Yuta Yamazaki : Measured the devices and processed the data.<br>
 
&nbsp;&nbsp;&nbsp;Hiraku Tokuma : Created the devices.<br>
 
&nbsp;&nbsp;&nbsp;Hiraku Tokuma : Created the devices.<br>
&nbsp;&nbsp;&nbsp;Riku Shinohara: Created the devices.<br>
+
&nbsp;&nbsp;&nbsp;Riku Shinohara : Created the devices.<br>
 
           <h2 id="Reference" class="smalltitle">5. Reference</h2>
 
           <h2 id="Reference" class="smalltitle">5. Reference</h2>
 
      <p class="text"><a href ="https://2014.igem.org/Team:Imperial/InterLab_Study">2014 Imperial Interlab Study</a><br><br><br>
 
      <p class="text"><a href ="https://2014.igem.org/Team:Imperial/InterLab_Study">2014 Imperial Interlab Study</a><br><br><br>

Revision as of 02:46, 15 September 2015

3OC12HSL-dependent growth assay

コメント

  
  

1. Introduction

      

2. Summary of the Experiment

      


3. Results

      

Table. 3-7-3-1. The absolute unit of fluorescence intensity



We calculated the arithmetic mean for each sample by adding the nine values of all three colonies and dividing it by 9. We also calculated the standard deviation for each sample from the calculated arithmetic mean. (Table. 3-7-3-2)

Table. 3-7-3-2. Arithmetic mean (Mean) and Standard deviation (S.D) of samples.


Fig.3-7-3-2. Results from the plate reader
The error bar represents the standard deviation for each sample calculated from the nine values of all three colonies.



3-2. Flow cytometer

      

We measured the geometric mean of fluorescence intensity for each sample. The results are shown below (Table.3-7-3-3). We measured three colonies(#1〜3) three times (Technical replicate 1〜3) per each sample (Device1〜3,positive control and negative control).
  These results show that the intensity of fluorescence was in the following order, Device1>Device2>positive control>Device3>negative control. (Table. 3-7-3-4)(Figure. 3-7-3-3)
  These results are the same as the results from the measurement done by the plate reader.

Table. 3-7-3-3. Results from the flow cytometer


Table. 3-7-3-4. Arithmetic mean (Mean) and Standard deviation (S.D) of samples.


Fig.3-7-3-3. Results from the flow cytometer 
The error bar represents the standard deviation for each sample calculated from the nine values of all three colonies.



4. Materials and Methods

4.1. Construction

-Strain

      

All the samples were DH5alpha strain.

-Plasmids

      

Device 1: J23101 + I13504(pSB1C3)

Fig.3-7-4-1.


      

Device 2: J23106 + I13504(pSB1C3)

Fig.3-7-4-2.


      

Device 1: J23117 + I13504(pSB1C3)

Fig.3-7-4-3.


      

Positive control: BBa_I20270(pSB1C3)

Fig.3-7-4-4.


      

Negative control: BBa_R0040(pSB1C3)

Fig.3-7-4-5.


-Sequence Data

      

Please refer to Sequence Data page.

4.2. Instruments and Date

4.2.1. Instruments

-Plate reader

We used FujiFilm FLA-5100 Fluorescent Image Analyzer from FUJI Film Life Science. The wavelength of light we used to excite the cells was 473 nm. We used BPB1 (530DF20) filter to capture the light emission from the cells. The sampling frequency is only one time.

-Flow cytomerer

We used BD FACSCaliburTM Flow Cytometer of Becton, Dickenson and Company. The wavelength of light we used to excite the cells was 488 nm. We used laser detection channel FL1 to capture the light emission from the cells. Laser detection channel Fl1 was used with sensitivity 680 [v]. The sampling frequency is only one time.

4.2.2. Date

Cloning of constructs was confirmed by October 21st 2015. Transformant plates were from 24 October 2015. All the samples were measured on October 27th 2015.

4.3. Protocol

4.3.1. Plate reader

1. Prepare 3 over night cultures for each sample Device1〜Device3, Positive control and Negative control in 3 mL LB medium containing chloramphenicol (35 microg / mL) at 37 °C for 17h and shake at 180 rpm.
2 .Measured the OD590 of each sample and diluted each sample to adjust OD590 within 5% of 0.5.
3. Set the plate reader to measure GFP.
4. Take 1 mL of the samples, and centrifuge at 9000x g, 1 min, 4°C.
5. Remove the supernatants by using P1000 pipette.
6. Add 1 mL of filtered PBS (phosphate-buffered saline) and suspend.
7. Place 200 μL of each sample into the 96-well plate as described in Table. 3-7-4-1.
8. Measure the fluorescence intensity with plate reader.
9. Rotate the 96-well plate 180 degrees horizontally and measure the fluorescence intensity again.

Table. 3-7-4-1. Position of samples in 96-well plate


4.3.2. Flow cytometer

1. Prepare 3 over night cultures for each sample Device1〜Device3, Positive control and Negative control in 3m LB medium containing chloramphenicol (35 microg / mL) at 37°C for 17h and shake at 180 rpm.
2. Start preparing the flow cytometer 1 h before the end of incubation.
3. Measure the OD590 and adjust the volume of each sample to centrifuge so that the amount of pellet will be about the same for every sample.
4. Centrifuge the samples at 9000x g, 1min, 4°C.
5. Remove the supernatants by using P1000 pipette and suspend the samples with 1mL of filtered PBS (phosphate-buffered saline).
6. Dispense all of each suspension into a disposable tube through a cell strainer.
7. Measure fluorescence intensity with flow cytometer.

4.4. How to process the data

4.4.1. Plate reader

-How to draw the calibration curve
1. Place 200 μL of various concentrations of sodium fluorescein (500, 375, 250, 125, 50, 25, 10, 5 ng / mL and PBS only) into the 96-well plate in triplicate.
2. Measure the fluorescence intensity with the plate reader.
3. Rotate the 96-well plate 180 degrees horizontally.
4. Measure the fluorescence intensity again.
5. Determine the auto-fluorescence of PBS by calculating the arithmetic mean of fluorescence intensity of PBS added in triplicate and use this value as the background fluorescence.
6. Subtract background fluorescence from each fluorescence intensity value of each well containing sodium fluorescein.
7. Take the arithmetic mean of the three technical replicates of sodium fluorescein of each concentration.
8. Draw the calibration curve.


-How to obtain the absolute unit of fluorescence intensity
1. Measure the fluorescence intensity with the plate reader.
2. Rotate the 96-well plate 180 degrees horizontally and measure the fluorescence intensity again.
3. Calculate the arithmetic mean of these two results.
4. Determine the auto-florescence of PBS by calculating the arithmetic mean of fluorescence intensity of PBS added in triplicate and use this value as the background fluorescence.
5. Subtract the background fluorescence from each well containing the samples.
6. Divide them by the value of OD590 of each sample.
7. Calculate the ng / mL fluorescence per OD590 unit by the formula we obtained from drawing the calibration curve.

4.4.2. Flow cytometer

Cells were gated according to the side scatter (SSC) and the forward scatter (FCS) to exclude cell debris and impurities.



4.5. Individuals responsible for conducting Interlab study

      

Misa Minegishi : Measured the devices and processed the data.
   Yuta Yamazaki : Measured the devices and processed the data.
   Hiraku Tokuma : Created the devices.
   Riku Shinohara : Created the devices.

5. Reference

      

2014 Imperial Interlab Study