Difference between revisions of "Team:Tokyo Tech/Description"

Line 46: Line 46:
 
           <h2 id="Summary" class="smalltitle">0. Summary</h2>
 
           <h2 id="Summary" class="smalltitle">0. Summary</h2>
 
           <p class="text">iGEM 2015 Tokyo_Tech improved the function of <a href="http://parts.igem.org/Part:BBa_K395160:Experience">BBa_K395160</a> by submission of <a href="http://parts.igem.org/Part:BBa_K1632020">BBa_K1632020</a>, and characterization of <a href="http://parts.igem.org/Part:BBa_K1333309">BBa_K1333309</a>, to meet gold medal criteria.</p>
 
           <p class="text">iGEM 2015 Tokyo_Tech improved the function of <a href="http://parts.igem.org/Part:BBa_K395160:Experience">BBa_K395160</a> by submission of <a href="http://parts.igem.org/Part:BBa_K1632020">BBa_K1632020</a>, and characterization of <a href="http://parts.igem.org/Part:BBa_K1333309">BBa_K1333309</a>, to meet gold medal criteria.</p>
           <p class="text">Furthermore, we have improved characterization of another previously existing part, RNA thermometer (FourU) coding sequence plasmid (<a href="http://parts.igem.org/Part:BBa_K1333309">BBa_K1333309</a>), constructed by iGEM 2014 SYSU-China by the following three points. <b>(1)</b> We measured the function of <a href="http://parts.igem.org/Part:BBa_K1333309">BBa_K1333309</a> at 42 ºC, which wasn’t confirmed by iGEM 2014 SYSU-China.  <b>(2)</b> We clarified the processing of the background derived from Negative control.  <b>(3)</b> We explicated that the measuring equipment was flow cytometer. (下2. RNA thermometerへのページ内リンク).</p>
+
           <p class="text">Furthermore, we have improved characterization of another previously existing part, RNA thermometer (FourU) coding sequence plasmid (<a href="http://parts.igem.org/Part:BBa_K1333309">BBa_K1333309</a>), constructed by iGEM 2014 SYSU-China by the following three points. <b>(1)</b> We measured the function of <a href="http://parts.igem.org/Part:BBa_K1333309">BBa_K1333309</a> at 42 ºC, which wasn’t confirmed by iGEM 2014 SYSU-China.  <b>(2)</b> We clarified the processing of the background derived from Negative control.  <b>(3)</b> We explicated that the measuring equipment was flow cytometer. <br>
 +
go to <h4 id="RNA">RNA thermometer</h4>.</p>
 
           <h2 id="ssrA" class="smalltitle">1. ssrAのパート</h2>
 
           <h2 id="ssrA" class="smalltitle">1. ssrAのパート</h2>
 
           <h2 id="RNA" class="smalltitle">2. RNA thermometer</h2>
 
           <h2 id="RNA" class="smalltitle">2. RNA thermometer</h2>
 +
              <h3 id="21" class="sub5">2.1. </h3>
 +
  
 
     </div>
 
     </div>
 
  </body>
 
  </body>
 
</html>
 
</html>

Revision as of 01:07, 18 September 2015

Description

    
  

0. Summary

iGEM 2015 Tokyo_Tech improved the function of BBa_K395160 by submission of BBa_K1632020, and characterization of BBa_K1333309, to meet gold medal criteria.

Furthermore, we have improved characterization of another previously existing part, RNA thermometer (FourU) coding sequence plasmid (BBa_K1333309), constructed by iGEM 2014 SYSU-China by the following three points. (1) We measured the function of BBa_K1333309 at 42 ºC, which wasn’t confirmed by iGEM 2014 SYSU-China. (2) We clarified the processing of the background derived from Negative control. (3) We explicated that the measuring equipment was flow cytometer.
go to

RNA thermometer

.

1. ssrAのパート

2. RNA thermometer

2.1.