Difference between revisions of "Team:ETH Zurich/Modeling/Single-cell Model"
Line 49: | Line 49: | ||
− | <h3> AND gate </h3> | + | <h3>AND gate</h3> |
<p> In our system we want to reduce the amount the amount of<a href= “https://2015.igem.org/Team:ETH_Zurich/Practices/Medicine”> false positives </a>. That’s why cells displaying intermediary characteristics should not be detected by our system. We consider that cells showing increased lactate production rate but do not expose phosphatidylserine, or cells exposing phosphatidylserine but not an increased lactate production rate should not be recognized by our system. We implemented the system to obtain an <a href="https://2015.igem.org/Team:ETH_Zurich/Glossary#AND_GATE">AND gate</a>. The system works as two sequential filtering step. <b> The sequential design </b> was used in order to limit the self-activation of the quorum sensing module .</b> Indeed as we have seen in the <a href="https://2015.igem.org/Team:ETH_Zurich/Modeling/AHL_Module">AHL module</a>, the difference between the two modules strongly depends on the amount of LuxR in the <i> E. coli </i>. This design has a disadvantage though, it requires fine-tuning in order to avoid that one signal prevails on the second one. In the scheme displayed below, we describe in which situation, the <i> E. coli </i> should display fluorescence. </p> | <p> In our system we want to reduce the amount the amount of<a href= “https://2015.igem.org/Team:ETH_Zurich/Practices/Medicine”> false positives </a>. That’s why cells displaying intermediary characteristics should not be detected by our system. We consider that cells showing increased lactate production rate but do not expose phosphatidylserine, or cells exposing phosphatidylserine but not an increased lactate production rate should not be recognized by our system. We implemented the system to obtain an <a href="https://2015.igem.org/Team:ETH_Zurich/Glossary#AND_GATE">AND gate</a>. The system works as two sequential filtering step. <b> The sequential design </b> was used in order to limit the self-activation of the quorum sensing module .</b> Indeed as we have seen in the <a href="https://2015.igem.org/Team:ETH_Zurich/Modeling/AHL_Module">AHL module</a>, the difference between the two modules strongly depends on the amount of LuxR in the <i> E. coli </i>. This design has a disadvantage though, it requires fine-tuning in order to avoid that one signal prevails on the second one. In the scheme displayed below, we describe in which situation, the <i> E. coli </i> should display fluorescence. </p> | ||
<p> One particularity of our system is that even healthy cells will produce lactate. That is why we implemented a <a href="https://2015.igem.org/Team:ETH_Zurich/Modeling/Lactate_Module#Full_module_simplified_model">lactate module</a> that works as a <a href="">fold-change sensor</a>. The fold change sensor will produce a pulse of LuxR. We will study here how the pulsed response influence the output of the system. </p> | <p> One particularity of our system is that even healthy cells will produce lactate. That is why we implemented a <a href="https://2015.igem.org/Team:ETH_Zurich/Modeling/Lactate_Module#Full_module_simplified_model">lactate module</a> that works as a <a href="">fold-change sensor</a>. The fold change sensor will produce a pulse of LuxR. We will study here how the pulsed response influence the output of the system. </p> | ||
Line 73: | Line 73: | ||
<h2> Combined Compartment Model </h2> | <h2> Combined Compartment Model </h2> | ||
<h3> Overview</h3> | <h3> Overview</h3> | ||
− | <p> With this model we plan to check whether our system can work as an AND gate. We will compare the output from the simple lactate detection system with the one from the system including the fold-change sensor. </p> | + | <p> With this model we plan to check whether our system can work as an <a href="#AND_gate">AND gate</a>. We will compare the output from the simple lactate detection system with the one from the system including the fold-change sensor. </p> |
<p> The equations are the integration of both modules in one compartment model. <p> | <p> The equations are the integration of both modules in one compartment model. <p> | ||
<h4> Assumptions</h4> | <h4> Assumptions</h4> | ||
<p> We assume:</p> | <p> We assume:</p> | ||
<ol> | <ol> | ||
− | <li> Instant diffusion in the compartments. | + | <li> Instant diffusion of AHL in the compartments. </li> |
<li> In all the following we assume the nanowell volume to be 1 nL. </li> | <li> In all the following we assume the nanowell volume to be 1 nL. </li> | ||
<li> All the <i> E. coli</i> receive the same amount of lactate. This is the worst-case scenario since probably the <i> E. coli</i> on the doughnut will sense a higher lactate production rate than the ones not bound, i.e., in the bulk.</li> | <li> All the <i> E. coli</i> receive the same amount of lactate. This is the worst-case scenario since probably the <i> E. coli</i> on the doughnut will sense a higher lactate production rate than the ones not bound, i.e., in the bulk.</li> | ||
Line 91: | Line 91: | ||
<img width="100%" src="https://static.igem.org/mediawiki/2015/0/0a/FoldChangeBehavior-AndGATE.png"> | <img width="100%" src="https://static.igem.org/mediawiki/2015/0/0a/FoldChangeBehavior-AndGATE.png"> | ||
</a> | </a> | ||
− | <p><b>Figure 3.</b> Simulation of the full system <b> with the fold change sensor </b></p> | + | <p><b>Figure 3.</b> Simulation of the full system <b> with the fold change sensor. Case 1) Lactate steady states are identical. Response of the system in four different situations. Lact+/QS+ corresponds to an <i>E. coli</i> next to a cancer cell,i.e. high lactate production and colocalization on the cancer cell's surface. Lact-/QS- correspond to the healthy cell's case, i.e. low lactate production rate and no colocalization. The other two situations displayed represent intermediary cell characteristics, i.e. high lactate production rate or colocalization on the mammalian cell's surface. </b></p> |
</div> | </div> | ||
<div class="imgBox"> | <div class="imgBox"> | ||
Line 97: | Line 97: | ||
<img width="100%" src="https://static.igem.org/mediawiki/2015/0/01/SimpleDetectionSystem-AndGATE.png"> | <img width="100%" src="https://static.igem.org/mediawiki/2015/0/01/SimpleDetectionSystem-AndGATE.png"> | ||
</a> | </a> | ||
− | <p><b>Figure 4.</b> Simulation of the full system <b> with the natural lactate detection system </b></p> | + | <p><b>Figure 4.</b> Simulation of the full system <b> with the natural lactate detection system. Case 1) Lactate steady states are identical. </b></p> |
</div> | </div> | ||
<h3> Simulation when the lactate concentration reach different steady states</h3> | <h3> Simulation when the lactate concentration reach different steady states</h3> | ||
Line 106: | Line 106: | ||
<img width="100%" src="https://static.igem.org/mediawiki/2015/b/b5/FoldChangeBehavior-AndGATEdifferentSS.png"> | <img width="100%" src="https://static.igem.org/mediawiki/2015/b/b5/FoldChangeBehavior-AndGATEdifferentSS.png"> | ||
</a> | </a> | ||
− | <p><b>Figure 5.</b> Simulation of the full system <b> with the fold change sensor </b></p> | + | <p><b>Figure 5.</b> Simulation of the full system <b> with the fold change sensor </b>. Case 2) Lactate steady states are separated.</p> |
</div> | </div> | ||
<div class="imgBox"> | <div class="imgBox"> | ||
Line 112: | Line 112: | ||
<img width="100%" src="https://static.igem.org/mediawiki/2015/9/9a/SimpleDetectionSystem-AndGATEdifferentSS.png"> | <img width="100%" src="https://static.igem.org/mediawiki/2015/9/9a/SimpleDetectionSystem-AndGATEdifferentSS.png"> | ||
</a> | </a> | ||
− | <p><b>Figure 6.</b> Simulation of the full system <b> with the natural lactate detection system </b></p> | + | <p><b>Figure 6.</b> Simulation of the full system <b> with the natural lactate detection system </b>. Case 2) Lactate steady states are separated</p> |
</div> | </div> | ||
<h3>Choosing the best design</h3> | <h3>Choosing the best design</h3> | ||
Line 123: | Line 123: | ||
<img width="100%" src="https://static.igem.org/mediawiki/2015/b/b3/HeatMapAndGATE.png"> | <img width="100%" src="https://static.igem.org/mediawiki/2015/b/b3/HeatMapAndGATE.png"> | ||
</a> | </a> | ||
− | <p><b>Figure 7.</b> | + | <p><b>Figure 7.</b> In silico GFP measurement experiment <b> with the fold change sensor </b>. The measurement was taken at a specific time point. We obtain an AND gate.</p> |
</div> | </div> | ||
</div> | </div> | ||
Line 218: | Line 218: | ||
<div class="expContainer"> | <div class="expContainer"> | ||
<h2>Summary</h2> | <h2>Summary</h2> | ||
− | <p> </p> | + | <p>The best design appears to be the fold-change sensor because the activation time differences are significantly increased. </p> |
+ | <p>Negligible effects not considered here: </p> | ||
+ | <ol> | ||
+ | <li>The lactate capture effect is not considered here, this effect </li> | ||
+ | <li></li> | ||
+ | </ol> | ||
</div> | </div> | ||
Revision as of 22:38, 18 September 2015
- Project
- Modeling
- Lab
- Human
Practices - Parts
- About Us
Compartment Model
Introduction and Goals
Figure 1. Full system genetic design. Lactate induces the lactate sensor. The output of the lactate sensor is LuxR. LuxR through initiation of the leakiness triggers the quorum sensing module. From this point, the E. coli cells are able to sense each other via AHL signaling
The combined compartment model studies the connections between the lactate module and the AHL module. The lactate sensor's output is LuxR. LuxR is the input of the AHL module. The system seems sequential but the actual input of the AHL module is the signaling molecule AHL. LuxR only induces leaky expression of the signaling molecule. However to activate the AHL module, a significant density of E. coli has to be reached. That is why the system should work as an AND gate.
Goals
By using the fitted parameters from both modules, we study how the system should function. We compare the response for two lactate designs. The first one is the combined model with the fold-change sensor. The second system is the one harboring the simple lactate detection system. For both designs, we use two different inputs: lactate production reaching the same steady state, or lactate production reaching two different steady states, as already explained in the lactate module. We then have the following goals:
- Choosing the best design: Does the simple natural detection system or a fold-change sensor lead to the best response?
- Performing an in silico GFP measurement for the chosen design: What is the measured GFP response time course during the experiment?
AND gate
In our system we want to reduce the amount the amount of false positives . That’s why cells displaying intermediary characteristics should not be detected by our system. We consider that cells showing increased lactate production rate but do not expose phosphatidylserine, or cells exposing phosphatidylserine but not an increased lactate production rate should not be recognized by our system. We implemented the system to obtain an AND gate. The system works as two sequential filtering step. The sequential design was used in order to limit the self-activation of the quorum sensing module . Indeed as we have seen in the AHL module, the difference between the two modules strongly depends on the amount of LuxR in the E. coli . This design has a disadvantage though, it requires fine-tuning in order to avoid that one signal prevails on the second one. In the scheme displayed below, we describe in which situation, the E. coli should display fluorescence.
One particularity of our system is that even healthy cells will produce lactate. That is why we implemented a lactate module that works as a fold-change sensor. The fold change sensor will produce a pulse of LuxR. We will study here how the pulsed response influence the output of the system.
Figure 2. Description of the AND gate
Combined Compartment Model
Overview
With this model we plan to check whether our system can work as an AND gate. We will compare the output from the simple lactate detection system with the one from the system including the fold-change sensor.
The equations are the integration of both modules in one compartment model.
Assumptions
We assume:
- Instant diffusion of AHL in the compartments.
- In all the following we assume the nanowell volume to be 1 nL.
- All the E. coli receive the same amount of lactate. This is the worst-case scenario since probably the E. coli on the doughnut will sense a higher lactate production rate than the ones not bound, i.e., in the bulk.
Equations
The equations are the combination of the compartment model of the AHL module and the lactate module.
The internal states: Lactate, LuxR, LuxRAHL, LuxI have the same ODEs than the single cell model. As already done in the compartment model, we just add convection between the different compartments.
Simulation when the lactate concentration reach the same steady states
Below you will find one example of a comparison between the response of a system including the fold change sensor and the one harboring only the natural detection system for the four different cases described earlier. The lactate inputs give two different delayed pulses of LuxR. The different pulses of LuxR lead to different delay of self-activation of the GFP output. The first GFP output to activate is the one with the cancer cell, the second and third one represent cells with intermediary characteristics. The latest activation time is for the one with no colocalization and no lactate production. With the fold-change sensor, we obtain a significant time difference between the different inputs. With only the natural detection system we do not obtain a clear difference between the different cases. The lactate signal prevails on the quorum sensing signal.
Figure 3. Simulation of the full system with the fold change sensor. Case 1) Lactate steady states are identical. Response of the system in four different situations. Lact+/QS+ corresponds to an E. coli next to a cancer cell,i.e. high lactate production and colocalization on the cancer cell's surface. Lact-/QS- correspond to the healthy cell's case, i.e. low lactate production rate and no colocalization. The other two situations displayed represent intermediary cell characteristics, i.e. high lactate production rate or colocalization on the mammalian cell's surface.
Figure 4. Simulation of the full system with the natural lactate detection system. Case 1) Lactate steady states are identical.
Simulation when the lactate concentration reach different steady states
Here we will compare again the response of the system when including the fold change sensor and the natural lactate detection system.
We can see that here again the fold change gives a better response for the same parameters.
Figure 5. Simulation of the full system with the fold change sensor . Case 2) Lactate steady states are separated.
Figure 6. Simulation of the full system with the natural lactate detection system . Case 2) Lactate steady states are separated
Choosing the best design
The fold-change sensor solved the problem of leakiness and the problems about the size of the nanowell plate we had earlier. The pulse of LuxR should be large enough in order to activate the quorum sensing module. A broader peak can be obtained by introducing a delay in the response of LacI. This can be easily implemented biologically (if needed) by introducing an intermediary protein between lactate induction and LacI production.
In silico GFP measurement experiment
As we have seen earlier, lactate production signals still prevail on the quorum sensing signal. In the broader context of our system, the experimenter will take the measurement at a specific time point. The heatmap represents the ratio of GFP output with and without colocalization on the doughnut for different rates of lactate production and different number of E. coli colocalized on the doughnut. In both cases, the E. coli receive the same amount of lactate.
We can see that depending on the rate of lactate production, there is an optimum for the fold change ratio between the GFP output. The GFP output depends a lot on the timescales because of the fold-change sensor.
Single cell model
Overview
The single cell model is provided here to simulate the combined model.
Chemical species
Name | Description |
---|---|
AHL | Signaling protein, Acyl homoserine lactone (30C6-HSL) |
LuxR | Regulator protein, that can bind to AHL to form a complex |
LuxRAHL | Complex of LuxR and AHL, activates transcription of LuxI |
LuxI | Autoinducer synthase |
Lact | Lactate |
LacI | Lac operon repressor, DNA-binding protein, acts as a protein |
IPTG | Isopropyl β-D-1-thiogalactopyranoside, prevents LacI from repressing the gene of interest |
IL | Dimer formed between LacI and IPTG |
Reactions
\begin{align*} &\mathop{\xrightarrow{\hspace{4em}}}_{a_{LacI},K_{A,appLact}}^{\displaystyle\mathop{\downarrow}^{\text{Lact}}} \text{LacI}\\ \text{IPTG} + \text{LacI} &\mathop{\mathop{\xrightarrow{\hspace{4em}}}^{\xleftarrow{\hspace{4em}}}}_{k_{\mathrm{IL}}}^{k_{\mathrm{-IL}}} \text{IL}\\ &\mathop{\xrightarrow{\hspace{4em}}}_{a_{LuxR},K_{A,appLact}}^{\displaystyle\mathop{\downarrow}^{\text{Lact}}} \text{LuxR}\\ &\mathop{\xrightarrow{\hspace{4em}}}_{a_{LuxR},K_{R,LacI}}^{\displaystyle\mathop{\bot}^{\text{LacI}}} \text{LuxR}\\ \text{AHL} + \text{LuxR} &\mathop{\mathop{\xrightarrow{\hspace{4em}}}^{\xleftarrow{\hspace{4em}}}}_{k_{\mathrm{LuxRAHL}}}^{k_{\mathrm{-LuxRAHL}}} \text{LuxRAHL}\\ &\mathop{\xrightarrow{\hspace{4em}}}_{a_\mathrm{LuxI},K_{\mathrm{a,LuxRAHL}}}^{\displaystyle\mathop{\downarrow}^{\text{LuxRAHL}}} \text{LuxI}\\ &\mathop{\xrightarrow{\hspace{4em}}}_{a_\mathrm{GFP},K_{\mathrm{a,LuxRAHL}}}^{\displaystyle\mathop{\downarrow}^{\text{LuxRAHL}}} \text{GFP}\\ \end{align*} | \begin{align*} \text{LuxI}&\mathop{\xrightarrow{\hspace{4em}}}^{a_{\mathrm{AHL}}}\text{AHL}+\text{LuxI}\\ \text{LuxR}&\mathop{\xrightarrow{\hspace{4em}}}^{d_{\mathrm{LuxR}}}\varnothing\\ \text{AHL}&\mathop{\xrightarrow{\hspace{4em}}}^{d_{\mathrm{AHL}}}\varnothing\\ \text{LuxRAHL}&\mathop{\xrightarrow{\hspace{4em}}}^{d_{\mathrm{LuxRAHL}}}\varnothing\\ \text{LuxI}&\mathop{\xrightarrow{\hspace{4em}}}^{d_{\mathrm{LuxI}}}\varnothing\\ \end{align*} |
Equations including the fold change sensor
Combining all of the equations from the two different modules, it yields the following system:
\begin{align*} \frac{d[LacI]}{dt}&=\frac{a_\mathrm{LacI} \cdot (\frac{[Lact]}{K_\mathrm{A,appLact}})^{n_1}}{1+(\frac{[Lact]}{K_\mathrm{A,appLact}})^{n_1}}-d_{\mathrm{LacI}}[LacI]\\ \frac{d[LuxR]}{dt}&=\frac{a_\mathrm{LuxR} \cdot (\frac{[Lact]}{K_\mathrm{A,appLact}})^{n_1}}{1+(\frac{[Lact]}{K_\mathrm{A,appLact}})^{n_1}} \cdot \frac{1}{1+(\frac{[LacI]}{K_{\mathrm{R,LacI}}\cdot (\gamma_2+1)})^{n_\mathrm{2}}}-d_{\mathrm{LuxR}}[LuxR]\\ [LuxRAHL]&= \frac{[AHL]\cdot [LuxR]}{K_{\mathrm{d,LuxRAHL}}+[AHL]}\\ \frac{d[LuxI]}{dt}&=a_{\mathrm{LuxI}}k_{\mathrm{leaky}}([LuxR]-[LuxRAHL])+\frac{a_{\mathrm{LuxI}}(\frac{[LuxRAHL]}{K_{\mathrm{A,LuxRAHL}}})^2}{1+(\frac{[LuxRAHL]}{K_{\mathrm{A,LuxRAHL}}})^2}-d_{\mathrm{LuxI}}[LuxI]\\ \frac{d[AHL]}{dt}&=a_{\mathrm{AHL}}[LuxI]-d_{\mathrm{AHL}}[AHL]\\ \frac{d[GFP]}{dt}&=a_\mathrm{GFP}k_{\mathrm{leaky}}([LuxR]-[LuxRAHL])+\frac{a_\mathrm{GFP}(\frac{[LuxRAHL]}{K_{\mathrm{A,LuxRAHL}}})^2}{1+(\frac{[LuxRAHL]}{K_{\mathrm{A,LuxRAHL}}})^2}-d_{\mathrm{GFP}}[GFP]\\ K_\mathrm{d,LuxRAHL} &= \frac{k_\mathrm{-LuxRAHL}}{k_\mathrm{LuxRAHL}}\\ \gamma_2 &= \frac{IPTG_{tot}}{K_{IL}} \end{align*}Equations including the natural detection system
\begin{align*} \frac{d[LuxR]}{dt}&=\frac{a_\mathrm{LuxR} \cdot (\frac{[Lact]}{K_\mathrm{A,appLact}})^{n_1}}{1+(\frac{[Lact]}{K_\mathrm{A,appLact}})^{n_1}}-d_{\mathrm{LuxR}}[LuxR]\\ [LuxRAHL]&= \frac{[AHL]\cdot [LuxR]}{K_{\mathrm{d,LuxRAHL}}+[AHL]}\\ \frac{d[LuxI]}{dt}&=a_{\mathrm{LuxI}}k_{\mathrm{leaky}}([LuxR]-[LuxRAHL])+\frac{a_{\mathrm{LuxI}}(\frac{[LuxRAHL]}{K_{\mathrm{A,LuxRAHL}}})^2}{1+(\frac{[LuxRAHL]}{K_{\mathrm{A,LuxRAHL}}})^2}-d_{\mathrm{LuxI}}[LuxI]\\ \frac{d[AHL]}{dt}&=a_{\mathrm{AHL}}[LuxI]-d_{\mathrm{AHL}}[AHL]\\ \frac{d[GFP]}{dt}&=a_\mathrm{GFP}k_{\mathrm{leaky}}([LuxR]-[LuxRAHL])+\frac{a_\mathrm{GFP}(\frac{[LuxRAHL]}{K_{\mathrm{A,LuxRAHL}}})^2}{1+(\frac{[LuxRAHL]}{K_{\mathrm{A,LuxRAHL}}})^2}-d_{\mathrm{GFP}}[GFP]\\ K_\mathrm{d,LuxRAHL} &= \frac{k_\mathrm{-LuxRAHL}}{k_\mathrm{LuxRAHL}}\\ \gamma_2 &= \frac{IPTG_{tot}}{K_{IL}} \end{align*}Summary
The best design appears to be the fold-change sensor because the activation time differences are significantly increased.
Negligible effects not considered here:
- The lactate capture effect is not considered here, this effect