Team:Marburg/InterLab
Materials and Methods
The parts for the three constructs used in the InterLab study (J23101, J23106, J23117 and I13504,) were taken from the iGEM distribution plates and transformed into NEB turbo cells. Afterwards, the plasmids were recovered through miniprep from an over night culture. The plasmids were amplified via PCR and purified by gel extraction. The final constructs were then assembled using CPEC cloning (Circular Polymerase Extension Cloning). The correct identity of the resulting constructs was confirmed by analytical digest with PvuII and sequencing. The final plasmids were transformed into DH5α cells. For the inoculation and cultivation we followed the recommended InterLab Protocol. We prepared our devices and the controls by streaking them out on agar plates from glycerol stocks. We incubated the plates 18h overnight at 37°C. For that we used LB Agar from Roth without antibiotic for the empty DH5alpha cells and LB Agar from Roth with Chloramphenicol (c=34 ug/ul) for the remaining strains carrying the constructs and controls. We inoculated our strains carrying the devices and controls in 5 mL LB with Chloramphenicol in a 15 mL Test tube. The empty DH5alpha cells were inoculated in 5 mL LB without antibiotic. For each sample we set up three biological replicas. The samples were incubated at 37°C at 300rpm for 16 h.
Measurement
For the plate reader measurement we measured the OD600 of our overnight cultures and therefore diluted them 1:10. As blank we used pure LB plus Chloramphenicol and LB without antibiotic for the empty DH5α cells. We measured our construct strains and the control strains with both the Spectrometer Ultrospec 10 from Amersham Bioscience and the Microplate Reader from Tecan. For the measurement of the fluorescence in the plate reader, the samples were diluted to an OD600 of 0,5 within a deviation of 5%. In order to generate meaningful results of each device, 3 biological and technical replicas were measured.
Results
We measured three different colonies (biological replicas) three times each (technical replicas). Data for each of them are summarized in Table 2.
The fluorescence data show a strong difference between the expression profiles of the promoters. The promoter J23101 shows a 17-fold stronger fluorescence signal than promoter J23106. The weakest promoter is J23117.
Disussion
Dolores blabalalalalskdfoaweihlasdfölsahdf