Team:Tokyo Tech/Description

Description

    
  

0. Summary

iGEM 2015 Tokyo_Tech improved the function of BBa_K395160 by submission of BBa_K1632020, and characterization of BBa_K1333309, to meet gold medal criteria.

Furthermore, we have improved characterization of another previously existing part, RNA thermometer (FourU) coding sequence plasmid (BBa_K1333309), constructed by iGEM 2014 SYSU-China by the following three points. (1) We measured the function of BBa_K1333309 at 42 ºC, which wasn’t confirmed by iGEM 2014 SYSU-China. (2) We clarified the processing of the background derived from Negative control. (3) We explicated that the measuring equipment was flow cytometer.
go to RNA thermometer.

1. ssrAのパート











2. RNA thermometer

2.1. "Background”for our characterization

Temperature increase is required in the expression of BBa_K1333309 (J23119_K115002_E1010) constructed by iGEM 2014 SYSU-China. RNA thermometers are located in the 5’-untranslated region (5’-UTR) and block the Shine-Dalgarno (SD) sequence by base pairing. Translation initiating temperature allows the disconnection of the coupling of the hydrogen bonds, which block the SD sequence at low temperature. Therefore, RNA thermometers change their conformations to the open state so that the ribosome could access the SD sequence and to initiate translation.

Although iGEM 2014 SYSU-China reported larger temperature dependency of RFP production dependent on RNA thermometers than the temperature dependency of a RFP production without RNA thermometers, it is hard to evaluate their results due to the lack of descriptions about the for negative controls. Their graph reported fluorescence intensities at 30ºC and at 37ºC for RFP expression controlled by the RNA thermometer. They further calculated the ratio in the expression. Additionally, intensities and ratio were reported also for RFP expression not controlled by the RNA thermometer. They, however, have not reported how these ratios were acquired or calculated. Furthermore, they have reported neither the fluorescence intensities nor the increasing ratios of the fluorescence intensity, of the sample [NC] at 30 ºC and at 37 ºC. Background fluorescence of negative control should be considered for such ratio calculation, especially in case of this part with low fluorescence intensity, which is shown afterwards in 3-3-3. Discussion. Given this situation, it can be speculated that the fluorescence intensities of the samples at 30 ºC and at 37 ºC written in the graph, are the values of each measured fluorescence intensity subtracted by the fluorescence intensity of Negative control. However, evaluation for different types of parts requires precise protocols so we cannot know for sure. A minor issue in their protocol is the lack of information on whether the measurement was done with the plate reader, which is affected by the medium and the fungus density, or done with the flow cytometer, which is not affected by these elements.

We thus improved characterization of BBa_K1333309 by (1) measuring the function of the part at 42 ºC, (2) explicating the way to deal with the background derived from Negative control, (3) measuring with the flow cytometer.


2.2. Summary of the experiment

Our purpose is to confirm the behavior of the RNA thermometer by setting Positive control and Negative control and to characterize the temperature dependence of the RNA thermometer at 30ºC, 37ºC and 42ºC by using the flow cytometer. We prepared the samples as shown below.


BBa_K1333309:J23119 promoter_RNA thermometer_rfp (pSB1C3)
Positive control: Plac _rfp_TT (pSB1C3)
Negative control: RNA thermometer_rfp (pSB1C3)

2.3. Result

We measured each sample at 30ºC, 37ºC and 42ºC. 37ºC is the translation initiating temperature. Little does the background from the medium affects results for the flow cytometer. Although iGEM 2014 SYSU-China confirmed the function of Pcon_RNA thermometer_rfp at these temperatures, we measured each sample at 42ºC, which is higher than the translation initiating temperature.


2.3.1 The fluorescence intensities of RFP

We found that the fluorescence intensities of both Pcon_RNA thermometer_rfp and Plac_rfp increased along with the rise of the temperature (Fig. 7-1-2-1).

Fig. 7-1-2-1. RAW data

The error bar represents the standard deviation for each sample calculated from the two values of all two colonies.

2.3.2. The standardized fluorescence intensities of RFP

2.3.2.1. The standardized fluorescence intensities of RFP

  We got the increasing ratios of fluorescence intensities at 37ºC and at 42ºC by dividing the each of the raw fluorescence intensities (Table. 7-1-2-1) by those at 30ºC. The increasing ratios of the Plac_rfp at 37ºC and 42ºC show that the fluorescence intensities increased dependent on temperature. We evaluated the increasing ratios of Pcon_RNA thermometer_rfp at 37ºC and 42ºC. Compared to the increasing ratios of Plac_rfp, those of the Pcon_RNA thermometer_rfp were higher at respective temperature. We observed not only the increase in the fluorescence intensities dependent on temperature but also the increase in the fluorescence intensities due to the function of the RNA thermometer (Table. 7-1-2-1). The increasing ratio of Pcon_RNA thermometer_rfp was 1.3 times higher than that of Plac_rfp at 37ºC. Furthermore, the increasing ratio of Pcon_RNA thermometer_rfp was 3.2 times higher that of Plac_rfp at 42ºC. These differences of the increasing ratios were dependent on the function of the RNA thermometer. We concluded that the RNA thermometer shows higher function at 42ºC compared to 37ºC.

Table. 7-1-2-1 The increasing ratios

2-3-2-2. The standardized fluorescence intensities of RFP after subtracting the background derived from the Negative control cell.

  By subtracting the fluorescence intensity of the RNAt_RFP (Fig. 7-1-2-1) from both the fluorescence intensities of Plac_rfp and Pcon_RNA thermometer_rfp (Fig. 7-1-2-1), each at the same temperature, we processed the background derived from the Negative control. We followed the increasing ratios with background subtraction as the section of the standardized fluorescence intensities of RFP, except this time we subtracted the backgrounds of all the fluorescence intensities. The increasing ratios of the Plac_rfp with background subtraction at 37ºC and at 42ºC show that the fluorescence intensities increased dependently on temperature. We evaluated the increasing ratios of Pcon_RNA thermometer_rfp with background subtraction at 37ºC and at 42ºC. Compared to the increasing ratios of Plac_rfp with background subtraction, those of the Pcon_RNA thermometer_rfp were higher at respective temperature. We observed not only the increase in the fluorescence intensities dependent on temperature but also the increase in the fluorescence intensities due to the function of the RNA thermometer (Table. 7-1-2-2). The increasing ratio of Pcon_RNA thermometer_rfp with background subtraction was 2.7 times higher than that of Plac_rfp at 37ºC. Furthermore, the increasing ratio of Pcon_RNA thermometer_rfp with background subtraction was 5.3 times higher that of Plac_rfp at 42ºC. These differences in the increasing ratios were dependent on the function of the RNA thermometer. We concluded that the RNA thermometer shows higher function at 42ºC compared to 37ºC.

Table. 7-1-2-2.The increasing ratios with background subtraction

2.4. Discussion

We examined that the reason the function of the RNA thermometer was worse at 37ºC than at 42ºC was that the amount of hydrogen bonds forming RNA thermometer was not enough to change in the structure of the RNA thermometer at 37ºC.

Furthermore, differences between the increasing ratios with and without background subtraction disclose the importance of background treatment. At 30 ºC, Pcon_RNA thermometer_rfp wasn’t translated enough and showed little expression of RFP. Since the fluorescence intensity of Pcon_RNA thermometer_rfp at 30ºC was small, the increasing ratios of the Pcon_RNA thermometer with and without background subtraction greatly differ in both 37ºC and 42ºC (Table. 7-1-2-3). Therefore, it is important to clarify whether the background derived from Negative control was processed or not.

Finally, we would confess that our measurement of the temperature dependence of RPF expression controlled by the RNA thermometer was part of our dilemma project to express the feeling of the E. coli which fell into a dilemma.

Table. 7-1-2-3. The difference the increasing ratios with and without background subtraction