iGEM 2015 Measurement Interlab Study

Introduction

All iGEM teams are invited and encouraged to participate in the Second International InterLab Measurement Study in synthetic biology. We’re hoping this study will get you excited for iGEM and help prepare you for the summer!

Please note: All Measurement Track teams are required to participate in the InterLab study.

The goal of the InterLab study is to obtain fluorescence data for three specific genetic devices expressing GFP from iGEM teams around the world. Can you measure fluorescence somewhere in your lab? Then this is the perfect study for you! Even if your lab or the organisms you work with mean that you can’t measure GFP from the specific devices, we want every team to be able to participate: email measurement at igem dot org and we will work out an alternative.

All teams who participate in the InterLab study will be acknowledged at the Giant Jamboree with a special Measurement Prize!

For any questions, contact measurement at igem dot org .

Registration and Timeline

Teams intending to participate in the InterLab study should sign up by emailing measurement at igem dot org .

Schedule:

  • Sign-up Deadline: TBD 2015
  • Data Due: TBD 2015
  • Results Announced, Prizes Awarded: At Giant Jamboree!

InterLab Study Requirements

  1. Each participating team must have an “InterLab Study” page on their wiki for easy reference for the Measurement Judges.
    1. All devices measured for this study should be listed on this page
    2. All protocols followed for this study should be linked/posted on this page
    3. Sequencing data for all measured devices should be posted on this page
      1. Note: A restriction map (a restriction digest run on a gel) confirming the correct size of the device will suffice if DNA sequencing is not possible
  1. Each team must use the three BioBrick devices listed below in the “Required Devices” section.
    1. Note: Teams are encouraged to measure more devices (see “Extra Credit” section below), but the three required devices must be included for the InterLab Study (unless an alternative set is required and negotiated via email to measurement at igem dot org .
  1. Each participating team must collect and submit fluorescence data for these three devices (the data will be submitted through the “InterLab Study” form, see step 4).
    1. This data may be obtained by any means possible for the teams. Any instrument capable of measuring GFP is acceptable!
    2. Measurement data should be submitted in absolute units if possible. There are many ways this can be done, depending on your lab. If your lab cannot measure absolute units, relative units are acceptable.
      1. Hint: if you have access to a flow cytometer, absolute units can be measured by calibrating against standard fluorescent beads. A method for doing so is described (and supported with online tools) at: TASBE Tools.
    1. Data must be measured in triplicate (i.e., three samples for each device).
      1. Note: The mean and standard deviation across the replicates must be included.
      2. All teams must fill in the “Interlab Study” form ((still in development))where they will indicate the equipment used to measure the cells, describe how the data was collected, and list all controls used.

Required Devices

The three specific devices teams are required to measure fluorescence data for are given below.

Devices are still being determined for 2015! Please check back often as we work on updating this material.

Suggested Culturing Conditions

Ideal culturing conditions for E. coli: Fluorescence should be measured after 16-18 hours of growth in a liquid culture (a simple overnight culture should work well). For E. coli, please grow the cultures in LB broth supplemented with the appropriate antibiotic. These should be grown at 37C with shaking (300 rpm, if possible). The strain of E. coli should be your normal cloning strain, ideally a DH5-alpha strain or similar (example: alpha-select cells from Bioline or Top10 cells from Invitrogen). The strain should be noted when sending in the data.

Non-E. coli Work: For non-E. coli work, these conditions and/or devices may not work in your cells; however, we still want you to participate! Please contact us at measurement at igem dot org and let us know what cell type/cell line you plan to use, your measurement protocol, and the constructs you plan to measure to participate in the Interlab Study.

Extra Credit Opportunity for the Interlab Study

Have you finished your Interlab Study requirements above? Still eager for some more measurement fun? Then these “extra credit” assignments are right for you!

For teams looking to do some measurement work beyond the interlab study requirements, we are offering three chances for “extra credit”. You can complete any or all of these extra credit assignments if you complete the Interlab Study.

Teams who go above and beyond the interlab study will be acknowledged for each “extra credit” assignment completed at the Giant Jamboree with a special Measurement Prize! Each assignment is weighed equally.

Please note: Your team must complete the Interlab Study requirements listed above in order to earn any “extra credit”!

Extra credit is still in development for 2015! Please check back regularly for updates.

For any questions, contact measurement at igem dot org .

GOOD LUCK!