Difference between revisions of "Team:Freiburg/Project/Overview"
Line 284: | Line 284: | ||
<div class="slidertext"> | <div class="slidertext"> | ||
<h1>Building our own device</h1> | <h1>Building our own device</h1> | ||
− | <p>The device orginally used, in collaboration with AG Roth, | + | <p>The device orginally used, in collaboration with AG Roth, is a pricy machine based on rather simple physics. Therefore, we decided to build our own apparatus in a cost-efficient manner. We were able to produce reliable results with it and provide a construction plan [LINK]. This plan will make it possible for future iGEM generations to built and use their own label-free protein array analysis tool.</p> |
</div> | </div> | ||
<div class="slidertext indent"> | <div class="slidertext indent"> | ||
Line 299: | Line 299: | ||
<div class="slidertext"> | <div class="slidertext"> | ||
<h1>Communicating science</h1> | <h1>Communicating science</h1> | ||
− | <p>Diagnosing diseases fast and reliable | + | <p>Diagnosing diseases fast and reliable is not only an issue among medical staff, it is also subject to public interest. This has lead us to ask for people's opinions regarding the DiaCHIP. Although the method is based on synthetic biology, which is a problematic definition for the broad public according to a survey initiated by the Leopoldina (National academy of science), we received lots of positive feedback. </p> |
</div> | </div> | ||
<div class="slidertext indent"> | <div class="slidertext indent"> | ||
Line 353: | Line 353: | ||
<!--korrigiert von Philipp05/09/15--> | <!--korrigiert von Philipp05/09/15--> | ||
<!--neu von Ramona08/09/15--> | <!--neu von Ramona08/09/15--> | ||
− | The DiaCHIP is an innovative tool to screen for a broad range of antibodies present in serum. Antibodies can be an indicator for an immune response towards an infection or a successful vaccination. Antibodies also play a role in the diagnosis of autoimmune diseases. Especially the ability to differentiate between life threatening diseases and a mild infection within | + | The DiaCHIP is an innovative tool to screen for a broad range of antibodies present in serum. Antibodies can be an indicator for an immune response towards an infection or a successful vaccination. Antibodies also play a role in the diagnosis of autoimmune diseases. Especially the ability to differentiate between life threatening diseases and a mild infection within a short time bears the potential to save lives. |
</br> | </br> | ||
− | Spotting diseases by detecting correspondent antibodies in a patient's serum is an established method in <a class="wikilink1" href="https://2015.igem.org/Team:Freiburg/Diagnostics" title="diagnostics_today">modern diagnostics</a>. The DiaCHIP makes | + | Spotting diseases by detecting correspondent antibodies in a patient's serum is an established method in <a class="wikilink1" href="https://2015.igem.org/Team:Freiburg/Diagnostics" title="diagnostics_today">modern diagnostics</a>. The DiaCHIP makes it possible to screen for mutiple specific antibodies using a simple blood sample <strong>(or drop?)</strong>. |
</br> | </br> | ||
The key feature of the DiaCHIP concept is the combination of on-demand protein synthesis and a novel method of label-free detection packed into one device. The idea is to overcome challenges commonly found in protein array production and preservation. In addition results can be obtained in a time- and cost-efficient manner; with a device simple enough to be rebuilt by future iGEM teams. (LINK – new device). | The key feature of the DiaCHIP concept is the combination of on-demand protein synthesis and a novel method of label-free detection packed into one device. The idea is to overcome challenges commonly found in protein array production and preservation. In addition results can be obtained in a time- and cost-efficient manner; with a device simple enough to be rebuilt by future iGEM teams. (LINK – new device). | ||
Line 365: | Line 365: | ||
<!--korrigiert von Philipp05/09/15--> | <!--korrigiert von Philipp05/09/15--> | ||
<!--neu von Ramona08/09/15--> | <!--neu von Ramona08/09/15--> | ||
− | Prior to screening for antibody-antigen interactions, the antigens have to be synthesized and immobilized in a microarray set-up. | + | Prior to screening for antibody-antigen interactions, the antigens have to be synthesized and immobilized in a microarray set-up. The DiaCHIP facilitates this process by a copying mechanism, which converts a DNA template into a protein microarray by cell-free protein expression. This expression system based on a bacterial lysate makes the need for genetically engineered organisms to produce each single antigen redundant. |
</br> | </br> | ||
− | In order to collect the DNA templates, the respective sequences containing transcriptional and translational initiation sites, the antigen coding sequence and terminating regions have to be constructed and labeled with an amino group. An activated | + | In order to collect the DNA templates, the respective sequences containing transcriptional and translational initiation sites, the antigen coding sequence and terminating regions have to be constructed and labeled with an amino group. An activated silicone slide provides the basis for immobilization of the DNA by covalent binding of the amino group. Spotting the antigen coding sequences in a distinct pattern enables to retrace a detected binding event to a certain disease. |
− | The template slide is placed in close proximity to the future protein array enabling the expressed proteins to reach this other surface by diffusion. | + | The template slide is placed in close proximity to the future protein array enabling the expressed proteins to reach this other surface by diffusion. We established a surface for specific immobilization of the target proteins. Thus, components of the expression mix can be washed away and do not hinder the analysis of the actual sample. |
</p> | </p> | ||
Line 379: | Line 379: | ||
</p> | </p> | ||
<p> | <p> | ||
− | After weeks of optimizing the different components of the DiaCHIP, we | + | After weeks of optimizing the different components of the DiaCHIP, we present our great results. The highlight of our project was reached with the successful <a href="https://2015.igem.org/Team:Freiburg/Results">detection of antibodies in our own blood!</a> |
</p> | </p> | ||
</div> <!-- end level1 --> | </div> <!-- end level1 --> |
Revision as of 19:01, 11 September 2015
Project overview: The DiaCHIP
The DiaCHIP is an innovative tool to screen for a broad range of antibodies present in serum. Antibodies can be an indicator for an immune response towards an infection or a successful vaccination. Antibodies also play a role in the diagnosis of autoimmune diseases. Especially the ability to differentiate between life threatening diseases and a mild infection within a short time bears the potential to save lives. Spotting diseases by detecting correspondent antibodies in a patient's serum is an established method in modern diagnostics. The DiaCHIP makes it possible to screen for mutiple specific antibodies using a simple blood sample (or drop?). The key feature of the DiaCHIP concept is the combination of on-demand protein synthesis and a novel method of label-free detection packed into one device. The idea is to overcome challenges commonly found in protein array production and preservation. In addition results can be obtained in a time- and cost-efficient manner; with a device simple enough to be rebuilt by future iGEM teams. (LINK – new device).
Step 1: Preparing the DiaCHIP by protein synthesis Prior to screening for antibody-antigen interactions, the antigens have to be synthesized and immobilized in a microarray set-up. The DiaCHIP facilitates this process by a copying mechanism, which converts a DNA template into a protein microarray by cell-free protein expression. This expression system based on a bacterial lysate makes the need for genetically engineered organisms to produce each single antigen redundant. In order to collect the DNA templates, the respective sequences containing transcriptional and translational initiation sites, the antigen coding sequence and terminating regions have to be constructed and labeled with an amino group. An activated silicone slide provides the basis for immobilization of the DNA by covalent binding of the amino group. Spotting the antigen coding sequences in a distinct pattern enables to retrace a detected binding event to a certain disease. The template slide is placed in close proximity to the future protein array enabling the expressed proteins to reach this other surface by diffusion. We established a surface for specific immobilization of the target proteins. Thus, components of the expression mix can be washed away and do not hinder the analysis of the actual sample.
Step 2: Measuring serum samples by iRIf After preparation of the DiaCHIP, a patient’s serum sample can be flushed over the protein array. The binding of antibodies to the protein surface causes a minimal change in the thickness of the slide right at the corresponding antigen spot. This change can be measured without the need for a further label with an emerging method called iRIf (imaging reflectometric interference). Based on the interference of light beams reflected on different thin layers, binding events can be recorded in real-time.
After weeks of optimizing the different components of the DiaCHIP, we present our great results. The highlight of our project was reached with the successful detection of antibodies in our own blood!