Difference between revisions of "Team:Freiburg/Project/System"
Line 194: | Line 194: | ||
<div class="content_box"> | <div class="content_box"> | ||
− | <h1>The DiaCHIP | + | <h1>The DiaCHIP - Overview</h1> |
<p> | <p> |
Revision as of 23:18, 18 September 2015
The DiaCHIP - Overview
Our DiaCHIP is a novel diagnostic device that offers the possibility for broadband screening of hundreds of diseases simultaneously. It is made up of an antigen array in a microfluidic chamber and can detect diseases via binding of corresponding antibodies. The antigens are fused to a tag and are produced with a cell-free expression mix, using a DNA array as template. The expressed antigens are arranged in an array structure, using a specific surface to stick them to a glass slide. Binding of antibodies can be detected with an optical method, thus providing the possibility of a label-free and real-time analysis.
The Backgrounds of the DiaCHIP
Step 1: Basic Setup of the DiaCHIP
The aim of our DiaCHIP is to screen simultaneously for hundreds of different infectious diseases. We based our system on the detection of antibodies specifically interacting with antigens derived from viruses and bacteria (figure 1). The antigens are produced by using a DNA array as template. The binding of antibodies to their corresponding antigens can be detected with a label-free detection method. Our setup is based on two components: a silicone slide where DNA coding for distinct antigenic peptides is immobilized and a glass slide with a specific surface to bind antigens. Both are about the size of a microscopy slide and form a microfluidic chamber. The antigens are expressed on demand by cell-free expression from the DNA array.
Step 2: Cell-Free Expressed Proteins
To enable the production of a protein array consisting of multiple antigens on demand, their expression is mediated by cell-free expression from a template DNA array. This expression system is based on bacterial lysate and makes the need for genetically engineered organisms to produce every single antigen redundant. The protein array is generated by flushing our cell-free expression mix through the microfluidic setup. Expressed antigens diffuse inside the system and immobilize on the opposite site of the DNA template (figure 2). Expressing the antigens from the DNA template, the protein array is adaptable to individual requirements exhibiting the same pattern for both arrays.
Step 3: A Specific Surface is Binding the Expressed Protein
After cell-free expression not only our desired antigens are present within the chamber, but also all other components of the cell-free mix including ribosomes, polymerases and amino acids (figure 3). All these components could bind unspecifically to the glass slide, thereby obstructing the binding of the antigens. To bind proteins specifically, we fused them with affinity tags. We designed our DNA constructs in a way that each antigen can easily be fused to specific tags. Testing different tag systems, we identified the Ni-NTA-His-tag system to be working best for our purposes. (A basic protocol for this specific surface was optimized by us to reduce unspecific binding.)
Step 4: The Measurement of Binding Events
The binding of antibodies to the corresponding surface causes a minimal change in the thickness of the layer on the slide just at the corresponding antigen spot. This binding can be detected label-free and in real-time using a novel technique called iRIf (imaging Reflectometric Interference) without the need for further labeling. Its main components are a camera, an LED and two lenses. See how we reconstructed the system in a low-budget device.
Step 5: Changing Perspectives - How are Antibody-Antigen Interactions Visualized?
When illustrating the basic principle of the DiaCHIP, we mainly looked at it from the side. Now it is time to explore our results and see what we actually achieved. Therefore, it is important to have in mind that you are observing the chip from the camera's position, so basically from the top (figure 5). This perspective remains the same in all the iRIf measurements we are showing in the results section.
After months of engineering and optimizing the different components of the DiaCHIP, we reached the highlight of our project with the successful detection of antibodies in our own blood!