Difference between revisions of "Team:Freiburg/Protocols/MesurementGFP"
(Created page with "{{Freiburg/CSS}} {{Freiburg/Menubar}} {{Freiburg/LabjournalCSS}} {{Freiburg/wiki_content_start}} <html><style> →========= BEGIN: style for navigation bar ==========: #noteb...") |
|||
Line 39: | Line 39: | ||
<hr/> | <hr/> | ||
</div> | </div> | ||
− | <h4> | + | |
+ | |||
+ | |||
+ | |||
+ | <h4>Measurement of expressed GFP</h4> | ||
<div class="level4"> | <div class="level4"> | ||
− | < | + | <ul> |
− | + | <li class="level1"><div class="li">All fluorescence measurements were performed with a microplate reader in blach plates with transparent bottom </div> | |
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | <li class="level1"><div class="li"> | + | |
</li> | </li> | ||
− | <li class="level1"><div class="li"> | + | <li class="level1"><div class="li">As Exitation wavelength 480nm were choosen </div> |
− | < | + | </li> |
+ | <li class="level1"><div class="li">Emission was measured at 520nm or a full spectrum was taken from 500 to 700 nm</div> | ||
+ | </li> | ||
+ | <li class="level1"><div class="li">Reactions were either performed in a tube and transferred to the microplate after the cell-free reaction or directly performed inside the platereader </div> | ||
+ | </li> | ||
+ | <li class="level1"><div class="li">when the reaction was performed inside the Platreader the wells were covered with foil to avoid evaporation</div> | ||
+ | </li> | ||
+ | <li class="level1"><div class="li"> After the reaction and Measurement samples were stored at 4°C for further folding or directly frozen at -20°C</div> | ||
+ | </ul> | ||
+ | |||
<div class="tags"><span> | <div class="tags"><span> |
Revision as of 22:56, 14 September 2015
Measurement of GFP Expression
Measurement of expressed GFP
- All fluorescence measurements were performed with a microplate reader in blach plates with transparent bottom
- As Exitation wavelength 480nm were choosen
- Emission was measured at 520nm or a full spectrum was taken from 500 to 700 nm
- Reactions were either performed in a tube and transferred to the microplate after the cell-free reaction or directly performed inside the platereader
- when the reaction was performed inside the Platreader the wells were covered with foil to avoid evaporation
- After the reaction and Measurement samples were stored at 4°C for further folding or directly frozen at -20°C