Our team followed the 2015 InterLab protocol for testing that was posted by iGEM for this study. Three separate biological replicate for the verified constructs and controls were grown in 10 mL culture tubes with loose caps in an incubator overnight for 16-18 hours. The OD500 of the cells was then taken and the samples were diluted to within 5% of 0.5. 150 microliters of three biological replicates of each diluted sample and three technical replicates were transferred to a 96 well plate. The fluorescence of the samples was then quantified a microplater reader. The model that was used for testing was the SpectraMax M2 microplate reader. The excitation wavelength was set to 498 nm and the emission spectrum was set at 541 nm with the auto cutoff setting on. We are also very thankful to Dr. Bentley's lab on campus for allowing us to use their plate reader for testing. The results of the experiments were processed are reported below in arbitrary units.
  
 