Difference between revisions of "Team:Goettingen/Experiments"

Line 37: Line 37:
 
}
 
}
  
#menu1, #menu2, #menu3, #menu4, #menu5, #menu6, #menu7, #menu8, #menu9, #menu10, #menu11, #menu12, #menu13, #menu14, #menu15, #menu16, #menu17, #menu18, #menu19, #menu20, #menu21, #menu22, #menu23, #menu24, #menu25, #menu26, #menu27, #menu28, #menu29, #menu30{
+
#menu1, #menu2, #menu3, #menu4, #menu5, #menu6, #menu7, #menu8, #menu9, #menu10, #menu11, #menu12, #menu13, #menu14, #menu15, #menu16, #menu17, #menu18, #menu19, #menu20, #menu21, #menu22, #menu23, #menu24, #menu25, #menu26, #menu27, #menu28, #menu29, #menu30, #menu31{
 
     display:none;
 
     display:none;
 
     width:90%;
 
     width:90%;
Line 876: Line 876:
 
     <p>&nbsp;</p>
 
     <p>&nbsp;</p>
 
</div>
 
</div>
                     
+
 
 +
<a href="" onClick=" $('#menu31').slideToggle(400, function callback() {  }); return false;"><h1>Esterase activity test</h1></a>
 +
<div id="menu31">
 +
 
 +
<p><strong>Materials:</strong></p>
 +
<ul>
 +
    <li>Freshly prepared AAM Solution (Acetone, 5N H<sub>2</sub>SO<sub>4</sub>, 10mM Ammonium molybdate, 2:1:1 v/v)</li>
 +
    <li>50 mM Sodium acetate buffer, pH 5.0</li>
 +
    <li>100 mM Pyrophosphate</li>
 +
    <li>Protein sample</li>
 +
</ul>
 +
<p><strong>Procedure:</strong></p>
 +
<ul>
 +
    <li>Set a heating block to 37&deg;C or 40&deg;C</li>
 +
    <li>Place 2 mL reaction tubes for each sample (technical triplicates) plus one blank in the heating block</li>
 +
    <li>Pipet 250 &micro;L of 50mM Sodium acetate buffer in all reaction tubes</li>
 +
    <li>Add 40 &micro;L of protein sample</li>
 +
    <li>Add 10 &micro;L of 100 mM Pyrophosphate to the tubes</li>
 +
    <li>Mix the tubes by inverting</li>
 +
    <li>Incubate on the heating block for 30 minutes</li>
 +
    <li>Add 1.5 mL of AAM solution and homogenize by inverting the tubes</li>
 +
    <li>Add 100 &micro;L Citric acid</li>
 +
    <li>If phosphatase is present, the colour will change from white/transparent to yellow</li>
 +
    <li>Measure the colour strength in a photometer at 335 nm</li>
 +
</ul>
 +
<p>CAUTION: Make sure that the buffer you used for protein extraction does not contain any phosphate components. Otherwise the test will be false positive!</p>
 +
</div>                     
  
 
<a href="" onClick=" $('#menu13').slideToggle(300, function callback() {  }); return false;">
 
<a href="" onClick=" $('#menu13').slideToggle(300, function callback() {  }); return false;">

Revision as of 09:01, 17 September 2015



Media

LB Medium

"Fat" LB Medium

Phosphatase Activity plates, Sperber media

Esterase Activity plates, with 1% Tributyrin

Cellulase activity plates

Cloning Methods

PCR product purification using QIAquick® PCR Purification Kit (QIAGEN)

PCR Gel extraction, peqGOLD Gel Extraction Kit

Blunt End Ligation in pJET1.2 vector –Clone JET PCR Cloning Kit–Thermo Scientific

TOPO® Cloning protocol usingChampion™ pET Directional TOPO® Expression Kits. Thermo Fisher Scientific

Plasmid transformation into chemically competent E. coli

Electroporation of BL21 cells with pJET_RFP

Plasmid Extraction - using QIAprep Spin Miniprep Kit (QIAGEN)

Plasmid Extraction - using peqGOLD Plasmid Miniprep Kit I (PEQLAB Technologies)

Competent Cells

Preparation of competent E.coli cells

Transformation Efficiency Kit, RFP construct (iGEM)

Protein Extraction and Purification

Protein Extraction (French Press) and Purification (Protino® Ni-IDA 2000 His-Tag protein purification, Macherey-Nagel)

Bradford Assay

Activity Screens

Esterase activity test

Esterase activity test

Cellulase activity screening

Restriction Controls

Aan I (Psi I ) - thermo fisher scientific - restriction control protocol

Double digestion restriction control

Restriction control using fast and slow digestion enzymes

Scafoldin Restriction control

Esterase Restriction Control

Phosphatase Restriction Control

PCR Preparation Methods

Colony PCR

Phusion PCR

Sequencing

Protocol for Sanger sequencing

Overnight Sanger Sequencing

Fluorescence Microscopy

RFP microscopy

Counting iGEM Goettingen2015.jpeg