Difference between revisions of "Team:Freiburg/Project/Overview"

Line 494: Line 494:
  
 
</div>
 
</div>
 +
 +
 +
  
 
<!---------------BEGIN SLIDER------------------>
 
<!---------------BEGIN SLIDER------------------>
Line 513: Line 516:
 
               </div>
 
               </div>
 
               <div class="slidertext">
 
               <div class="slidertext">
                 <h1>Building our own device</h1>
+
                 <h1>(1)The DiaCHIP - System Overview</h1>
                 <p>The device originally used, in collaboration with AG Roth, is an expensive machine based on rather simple components. Therefore, we decided to build our apparatus in a cost-efficient manner. We were able to produce reliable results with it and provide a <a href="https://2015.igem.org/Team:Freiburg/Results/Own_Device#howto_anchor">construction plan</a>. This plan will make it possible for future iGEM generations to build and use their own label-free protein array analysis tool.</p>
+
                 <p>The core of our new diagnostic device are two slides that form a microfluidic chamber. Therein an antigen array can be generated on demand on the bottom slide. By flushing the chamber with a blood sample, binding of antibodies present in the sample is detected with the optical detection method iRIf in real-time.</p>
 
               </div>
 
               </div>
 
               <div class="slidertext indent">
 
               <div class="slidertext indent">
Line 528: Line 531:
 
               </div>
 
               </div>
 
               <div class="slidertext">
 
               <div class="slidertext">
                 <h1>Communicating science</h1>
+
                 <h1>(2)Communicating science</h1>
 
                 <p>Diagnosing diseases fast and reliable is not only an issue among medical staff, it is also subject to public interest. This has lead us to ask for people's opinions regarding the DiaCHIP. Although the method is based on synthetic biology, which is a problematic term for the broad public according to a survey initiated by the Leopoldina (National academy of science), we received a lot of positive feedback. </p>
 
                 <p>Diagnosing diseases fast and reliable is not only an issue among medical staff, it is also subject to public interest. This has lead us to ask for people's opinions regarding the DiaCHIP. Although the method is based on synthetic biology, which is a problematic term for the broad public according to a survey initiated by the Leopoldina (National academy of science), we received a lot of positive feedback. </p>
 
               </div>
 
               </div>
Line 542: Line 545:
 
               </div>
 
               </div>
 
               <div class="slidertext">  
 
               <div class="slidertext">  
                 <h1>Modeling cell-free expression</h1>
+
                 <h1>(3)Modeling cell-free expression</h1>
 
                 <p>In order to optimize the DiaCHIP for future applications, we optimized the process of cell-free expression and diffusion over time. Making use of xxx parameters and xxx ordinary differential equations, we computed the size of the resulting antigen spots on the protein array and identified the factors limiting cell-free expression in the DiaCHIP. </p>
 
                 <p>In order to optimize the DiaCHIP for future applications, we optimized the process of cell-free expression and diffusion over time. Making use of xxx parameters and xxx ordinary differential equations, we computed the size of the resulting antigen spots on the protein array and identified the factors limiting cell-free expression in the DiaCHIP. </p>
 
               </div>
 
               </div>
Line 556: Line 559:
 
               </div>
 
               </div>
 
               <div class="slidertext">  
 
               <div class="slidertext">  
                 <h1>Measuring our blood</h1>
+
                 <h1>(4)Measuring our blood</h1>
 
                 <p>One of the most promising results was obtained from the detection of anti-tetanus antibodies in human blood serum. The DiaCHIP analysis made it possible for us to distinguish serum samples from a team member before and after vaccination. Samples taken two weeks after vaccination produced higher signals, compared to those prior to antigen exposure.</p>
 
                 <p>One of the most promising results was obtained from the detection of anti-tetanus antibodies in human blood serum. The DiaCHIP analysis made it possible for us to distinguish serum samples from a team member before and after vaccination. Samples taken two weeks after vaccination produced higher signals, compared to those prior to antigen exposure.</p>
 
               </div>
 
               </div>
Line 570: Line 573:
 
               </div>
 
               </div>
 
               <div class="slidertext">  
 
               <div class="slidertext">  
                 <h1>DNA Engineering</h1>
+
                 <h1>(5)DNA Engineering</h1>
 
                 <p>Genetic fusion of different antigens and tags is a really basic requirement of our project. To enable many people to work on our DNA constructs in parallel we designed a cloning strategy easy to follow and additionally easy to expand for further needs.
 
                 <p>Genetic fusion of different antigens and tags is a really basic requirement of our project. To enable many people to work on our DNA constructs in parallel we designed a cloning strategy easy to follow and additionally easy to expand for further needs.
 
                                 <br>
 
                                 <br>
Line 587: Line 590:
 
               </div>
 
               </div>
 
               <div class="slidertext">  
 
               <div class="slidertext">  
                 <h1>Protein purification</h1>
+
                 <h1>(6)Protein purification</h1>
 
                 <p>Protein expression in the DiaCHIP is mediated by cell-free expression. As this is an advanced method dependent on the optimization of many parameters, we got back to conventional protein purification in <i>E. coli</i> for being able to compare the results of both techniques. <br>
 
                 <p>Protein expression in the DiaCHIP is mediated by cell-free expression. As this is an advanced method dependent on the optimization of many parameters, we got back to conventional protein purification in <i>E. coli</i> for being able to compare the results of both techniques. <br>
 
<a class="wikilink1" href="https://2015.igem.org/Team:Freiburg/Project/Protein_Purification">Read more</a> about the overexpression and purification of several antigenic peptides.   
 
<a class="wikilink1" href="https://2015.igem.org/Team:Freiburg/Project/Protein_Purification">Read more</a> about the overexpression and purification of several antigenic peptides.   
Line 603: Line 606:
 
               </div>
 
               </div>
 
               <div class="slidertext">  
 
               <div class="slidertext">  
                 <h1>Surface chemistry</h1>
+
                 <h1>(7)Surface chemistry</h1>
 
                 <p>The production of a protein microarray in the DiaCHIP is based on specific immobilization of antigenic peptides on a glass slide. Therefore, we optimized a protocol for a specific surface chemistry until the proportion of unspecific binding of non-target proteins was reduced to a minimum.<br>
 
                 <p>The production of a protein microarray in the DiaCHIP is based on specific immobilization of antigenic peptides on a glass slide. Therefore, we optimized a protocol for a specific surface chemistry until the proportion of unspecific binding of non-target proteins was reduced to a minimum.<br>
 
<a class="wikilink1" href="https://2015.igem.org/Team:Freiburg/Project/Surface_Chemistry">Read more</a> about the different systems we tested on our way to high specificity.
 
<a class="wikilink1" href="https://2015.igem.org/Team:Freiburg/Project/Surface_Chemistry">Read more</a> about the different systems we tested on our way to high specificity.
Line 619: Line 622:
 
               </div>
 
               </div>
 
               <div class="slidertext">  
 
               <div class="slidertext">  
                 <h1>Optical detection</h1>
+
                 <h1>(8)Optical detection</h1>
 
                 <p>One disadvantage of currently available diagnostic test is the need for secondary labels that allow the detection of disease markers. Making use of an optical method based on the interference of light, the DiaCHIP can detect specific binding events on a protein microarray without further labeling. <br>
 
                 <p>One disadvantage of currently available diagnostic test is the need for secondary labels that allow the detection of disease markers. Making use of an optical method based on the interference of light, the DiaCHIP can detect specific binding events on a protein microarray without further labeling. <br>
 
<a class=”wikilink1” href=”https://2015.igem.org/Team:Freiburg/Project/iRIf>Read more</a> about this innovative tool and the physics behind it.
 
<a class=”wikilink1” href=”https://2015.igem.org/Team:Freiburg/Project/iRIf>Read more</a> about this innovative tool and the physics behind it.

Revision as of 11:36, 17 September 2015

""

expand text s.t. it leads to system overview
write appropriate content for slider: should present main subpoints of project in short sentence and link to them

The DiaCHIP - A Versatile Detection System

DiaCHIP_Sabi

Project Motivation

Serological tests are a key element in modern medicine. Especially for detection and identification of infectious diseases, performing several blood tests is inevitable. Testing for more than one disease at a time or diagnosing a patient with diffuse symptoms usually requires more than one serological test. Every single test that is performed increases the time of waiting for a result as well as the bill. In case of dangerous infectious diseases every minute until the onset of the appropriate treatment is important for life. What if there was a possibility to combine all this testing in one single chip which is affordable for everyone?

Detecting Antigen-Antibody Interactions

The DiaCHIP is an innovative tool to screen for a broad range of antibodies present in serum. Antibodies serve as indicator for an immune response towards an infectious diseases or a successful vaccination. They also play an important role in the diagnosis of autoimmune diseases. Identifying diseases by detecting disease associated antibodies in a patient's serum is an established method in modern diagnostics.
Based on the very same principle, the DiaCHIP enables to simultaneously screen for multiple diseases at time, thereby reducing time and cost of a diagnosis. Especially the ability to differentiate between life threatening diseases and mild infections within a short time bears the potential to save lives.

The Concept

The key feature of the DiaCHIP concept is the combination of on-demand protein synthesis of disease related antigens and a novel method for label-free detection - all this packed into one device. The idea is to overcome challenges commonly found in protein array production and preservation. In addition, results can be obtained in a time- and cost-efficient manner; with a device simple enough to be rebuilt by future iGEM Teams.

  • (1)The DiaCHIP - System Overview

    The core of our new diagnostic device are two slides that form a microfluidic chamber. Therein an antigen array can be generated on demand on the bottom slide. By flushing the chamber with a blood sample, binding of antibodies present in the sample is detected with the optical detection method iRIf in real-time.

    Want to read more?

  • (2)Communicating science

    Diagnosing diseases fast and reliable is not only an issue among medical staff, it is also subject to public interest. This has lead us to ask for people's opinions regarding the DiaCHIP. Although the method is based on synthetic biology, which is a problematic term for the broad public according to a survey initiated by the Leopoldina (National academy of science), we received a lot of positive feedback.

    Want to read more?

  • (3)Modeling cell-free expression

    In order to optimize the DiaCHIP for future applications, we optimized the process of cell-free expression and diffusion over time. Making use of xxx parameters and xxx ordinary differential equations, we computed the size of the resulting antigen spots on the protein array and identified the factors limiting cell-free expression in the DiaCHIP.

    Want to read more?

  • (4)Measuring our blood

    One of the most promising results was obtained from the detection of anti-tetanus antibodies in human blood serum. The DiaCHIP analysis made it possible for us to distinguish serum samples from a team member before and after vaccination. Samples taken two weeks after vaccination produced higher signals, compared to those prior to antigen exposure.

    Want to read more?

  • (5)DNA Engineering

    Genetic fusion of different antigens and tags is a really basic requirement of our project. To enable many people to work on our DNA constructs in parallel we designed a cloning strategy easy to follow and additionally easy to expand for further needs.
    Read more about how we combined different cloning methods to reduce our efforts in DNA Engineering.

    Want to read more?

  • (6)Protein purification

    Protein expression in the DiaCHIP is mediated by cell-free expression. As this is an advanced method dependent on the optimization of many parameters, we got back to conventional protein purification in E. coli for being able to compare the results of both techniques.
    Read more about the overexpression and purification of several antigenic peptides.

    Want to read more?

  • (7)Surface chemistry

    The production of a protein microarray in the DiaCHIP is based on specific immobilization of antigenic peptides on a glass slide. Therefore, we optimized a protocol for a specific surface chemistry until the proportion of unspecific binding of non-target proteins was reduced to a minimum.
    Read more about the different systems we tested on our way to high specificity.

    Want to read more?

  • (8)Optical detection

    One disadvantage of currently available diagnostic test is the need for secondary labels that allow the detection of disease markers. Making use of an optical method based on the interference of light, the DiaCHIP can detect specific binding events on a protein microarray without further labeling.
    Read more about this innovative tool and the physics behind it.

    Want to read more?