Difference between revisions of "Team:Freiburg/Project/System"
Line 21: | Line 21: | ||
− | |||
<div class="content_box"> | <div class="content_box"> | ||
− | |||
− | |||
− | <h1 | + | <h1>The DiaCHIP : Overview</h1> |
− | + | ||
<p> | <p> | ||
− | The DiaCHIP is a diagnostic device that offers the possibility for broadband screening for hundreds of diseases simultaneously. By detecting antibodies which indicate an immune response against infections or a successful vaccination, it can differentiate between | + | The DiaCHIP is a diagnostic device that offers the possibility for broadband screening for hundreds of diseases simultaneously. By detecting antibodies which indicate an immune response against infections or a successful vaccination, it can differentiate between a simple fever and life threatening infections, for example. All that is needed for this broadband test is a single drop of a patient's blood. <br> |
The DiaCHIP allows a fast diagnosis and therefore shortens the time till a patient gets the required treatment. | The DiaCHIP allows a fast diagnosis and therefore shortens the time till a patient gets the required treatment. | ||
− | |||
</p> | </p> | ||
Line 38: | Line 33: | ||
<h2>Step 1: Basic Setup of the DiaCHIP</h2> | <h2>Step 1: Basic Setup of the DiaCHIP</h2> | ||
− | <div class="image_box | + | <div class="image_box right"> |
<div class="thumb2 trien" style="width:310px"> | <div class="thumb2 trien" style="width:310px"> | ||
Line 56: | Line 51: | ||
</div> | </div> | ||
− | + | </div> | |
− | + | </div> | |
− | + | </div> | |
− | + | ||
<p> | <p> | ||
− | The aim of our DiaCHIP is to screen simultaneously for hundreds of different infectious diseases. We based our system on the detection of antibodies specifically interacting with antigens derived from viruses and bacteria (figure 1). If you get in contact with one of these pathogens your immune system is producing antibodies. These are binding to the corresponding antigen, which can be detected with | + | The aim of our DiaCHIP is to screen simultaneously for hundreds of different infectious diseases. We based our system on the detection of antibodies specifically interacting with antigens derived from viruses and bacteria (figure 1). If you get in contact with one of these pathogens your immune system is producing antibodies. These are binding to the corresponding antigen, which can be detected with the DiaCHIP. |
Our approach is based on two components: a silicone slide where DNA coding for distinct antigenic peptides is immobilized and a glass slide with a specific surface for the binding of the expressed antigens. Both are about the size of a microscopy slide and form a microfluidic chamber. By adding blood of a patient, antibodies that might be present in the sample due to a disease bind to the corresponding antigens. | Our approach is based on two components: a silicone slide where DNA coding for distinct antigenic peptides is immobilized and a glass slide with a specific surface for the binding of the expressed antigens. Both are about the size of a microscopy slide and form a microfluidic chamber. By adding blood of a patient, antibodies that might be present in the sample due to a disease bind to the corresponding antigens. | ||
</p> | </p> | ||
− | |||
</div> | </div> | ||
Line 88: | Line 81: | ||
</a> | </a> | ||
− | <p><strong>Figure 2: The expression of | + | <p><strong>Figure 2: The expression of the antigens is achieved by our cell-free expression mix.</strong> This mix is based on a bacterial lysate and contains all components required for transcription and translation of the DNA sequences.</p> |
</div> | </div> | ||
Line 98: | Line 91: | ||
<p> | <p> | ||
− | To enable the production of a protein array consisting of multiple antigens on demand, their expression is mediated by cell-free expression from a <a href="https://2015.igem.org/Team:Freiburg/Results/Immobilization"target="_blank">template DNA array</a>. This expression system based on | + | To enable the production of a protein array consisting of multiple antigens on demand, their expression is mediated by cell-free expression from a <a href="https://2015.igem.org/Team:Freiburg/Results/Immobilization"target="_blank">template DNA array</a>. This expression system based on bacterial lysate makes the need for genetically engineered organisms to produce every single antigen redundant. |
The protein array is generated by flushing <a href="https://2015.igem.org/Team:Freiburg/Results/Cellfree"target="_blank">our cell-free expression mix</a> through the microfluidic setup. Expressing the antigens from the DNA template, the protein array is adaptable to individual requirements exhibiting the same pattern for both arrays. | The protein array is generated by flushing <a href="https://2015.igem.org/Team:Freiburg/Results/Cellfree"target="_blank">our cell-free expression mix</a> through the microfluidic setup. Expressing the antigens from the DNA template, the protein array is adaptable to individual requirements exhibiting the same pattern for both arrays. | ||
Our system is made up of two slides enabling the antigens to be immobilized on the opposite side of the DNA template inside the microfluidic chamber (figure 2). | Our system is made up of two slides enabling the antigens to be immobilized on the opposite side of the DNA template inside the microfluidic chamber (figure 2). | ||
Line 105: | Line 98: | ||
<div class="float_barrier"></div> | <div class="float_barrier"></div> | ||
− | < | + | |
+ | <p> | ||
<h2>Step 3: A Specific Surface is Catching the Expressed Protein</h2> | <h2>Step 3: A Specific Surface is Catching the Expressed Protein</h2> | ||
− | <div class="image_box | + | <div class="image_box right"> |
<div class="thumb2 trien" style="width:250px"> | <div class="thumb2 trien" style="width:250px"> | ||
Line 122: | Line 116: | ||
</a> | </a> | ||
− | <p><strong>Figure 3: Surface immobilization.</strong>To prevent unspecific binding of components of the cell-free expression mix | + | <p><strong>Figure 3: Surface immobilization.</strong>To prevent unspecific binding of components of the cell-free expression mix on the glass slide, we established a surface that specifically binds our target proteins, the antigens.</p> |
</div> | </div> | ||
Line 130: | Line 124: | ||
</div> | </div> | ||
</div> | </div> | ||
+ | </p> | ||
<p> | <p> | ||
− | After cell-free expression not only our desired antigens are present within the chamber, but also all other components of the cell-free mix including ribosomes, polymerases | + | After cell-free expression not only our desired antigens are present within the chamber, but also all other components of the cell-free mix including ribosomes, polymerases and amino acids (figure 3). |
− | All these components would bind unspecifically to an activated glass slide, thereby obstructing the binding of the antigens. We designed our DNA constructs in a way that each antigen can easily be fused to specific tags that enable targeted immobilization on a specific surface. Testing different tag systems, we found the Ni-NTA-His-tag system | + | All these components would bind unspecifically to an activated glass slide, thereby obstructing the binding of the antigens. We designed our DNA constructs in a way that each antigen can easily be fused to specific tags that enable targeted immobilization on a specific surface. Testing different tag systems, we found the Ni-NTA-His-tag system to be working best for our purposes. A basic protocol for this <a href="https://2015.igem.org/Team:Freiburg/Results/Surface"target="_blank">specific surface</a> was optimized by ourselves to reduce unspecific binding. |
</p> | </p> | ||
− | + | ||
<div class="float_barrier"></div> | <div class="float_barrier"></div> | ||
− | < | + | <p> |
<h2>Step 4: The Measurement of Binding Events</h2> | <h2>Step 4: The Measurement of Binding Events</h2> | ||
Line 156: | Line 151: | ||
<p><strong>Figure 4: Optical detection method.</strong> The detection system mainly consists of a camera and an LED and is called <a href="https://2015.igem.org/Team:Freiburg/Project/iRIf"target="_blank">iRIf</a> (imaging Reflectometric Interference). Antigen-Antibody interactions can be detected label-free and in real-time. An optical output of such binding events is generated by a minimal change in the thickness of the layer on the slide right at the corresponding antigen spot.</p> | <p><strong>Figure 4: Optical detection method.</strong> The detection system mainly consists of a camera and an LED and is called <a href="https://2015.igem.org/Team:Freiburg/Project/iRIf"target="_blank">iRIf</a> (imaging Reflectometric Interference). Antigen-Antibody interactions can be detected label-free and in real-time. An optical output of such binding events is generated by a minimal change in the thickness of the layer on the slide right at the corresponding antigen spot.</p> | ||
</div> | </div> | ||
− | |||
</div> | </div> | ||
</div> | </div> | ||
</div> | </div> | ||
+ | </p> | ||
+ | |||
<p> | <p> | ||
− | After preparation of the DiaCHIP, a patient’s serum sample can be flushed over the protein array using the same microfluidic system. The binding of antibodies to the corresponding surface causes a minimal change in the thickness of the layer on the slide right at the corresponding antigen spot. This binding can be detected label-free and in real-time using a novel technique called <a href="https://2015.igem.org/Team:Freiburg/Project/iRIf"target="_blank">iRIf</a> (imaging Reflectometric Interference) without the need for further labeling. Its core components are a camera, an LED and | + | After preparation of the DiaCHIP, a patient’s serum sample can be flushed over the protein array using the same microfluidic system. The binding of antibodies to the corresponding surface causes a minimal change in the thickness of the layer on the slide right at the corresponding antigen spot. This binding can be detected label-free and in real-time using a novel technique called <a href="https://2015.igem.org/Team:Freiburg/Project/iRIf"target="_blank">iRIf</a> (imaging Reflectometric Interference) without the need for further labeling. Its core components are a camera, an LED and two lenses. |
See how we reconstructed the system in a <a href="https://2015.igem.org/Team:Freiburg/Results/Own_Device"target="_blank">low-budget device</a>. | See how we reconstructed the system in a <a href="https://2015.igem.org/Team:Freiburg/Results/Own_Device"target="_blank">low-budget device</a>. | ||
</p> | </p> | ||
− | + | ||
<div class="float_barrier"></div> | <div class="float_barrier"></div> | ||
+ | <p> | ||
<h2>Step 5: Changing Perspectives - Off to our Results </h2> | <h2>Step 5: Changing Perspectives - Off to our Results </h2> | ||
− | <div class="image_box | + | <div class="image_box right"> |
<div class="thumb2 trien" style="width:310px"> | <div class="thumb2 trien" style="width:310px"> | ||
<div class="thumbinner"> | <div class="thumbinner"> | ||
Line 182: | Line 179: | ||
</div> | </div> | ||
</div> | </div> | ||
+ | </p> | ||
<p> | <p> | ||
Line 192: | Line 190: | ||
</p> | </p> | ||
</div> | </div> | ||
+ | |||
+ | <a href="">Link zu Results</a> | ||
Revision as of 01:41, 18 September 2015
The DiaCHIP : Overview
The DiaCHIP is a diagnostic device that offers the possibility for broadband screening for hundreds of diseases simultaneously. By detecting antibodies which indicate an immune response against infections or a successful vaccination, it can differentiate between a simple fever and life threatening infections, for example. All that is needed for this broadband test is a single drop of a patient's blood.
The DiaCHIP allows a fast diagnosis and therefore shortens the time till a patient gets the required treatment.
Step 1: Basic Setup of the DiaCHIP
The aim of our DiaCHIP is to screen simultaneously for hundreds of different infectious diseases. We based our system on the detection of antibodies specifically interacting with antigens derived from viruses and bacteria (figure 1). If you get in contact with one of these pathogens your immune system is producing antibodies. These are binding to the corresponding antigen, which can be detected with the DiaCHIP. Our approach is based on two components: a silicone slide where DNA coding for distinct antigenic peptides is immobilized and a glass slide with a specific surface for the binding of the expressed antigens. Both are about the size of a microscopy slide and form a microfluidic chamber. By adding blood of a patient, antibodies that might be present in the sample due to a disease bind to the corresponding antigens.
Step 2: Cell-Free Expressed Proteins
To enable the production of a protein array consisting of multiple antigens on demand, their expression is mediated by cell-free expression from a template DNA array. This expression system based on bacterial lysate makes the need for genetically engineered organisms to produce every single antigen redundant. The protein array is generated by flushing our cell-free expression mix through the microfluidic setup. Expressing the antigens from the DNA template, the protein array is adaptable to individual requirements exhibiting the same pattern for both arrays. Our system is made up of two slides enabling the antigens to be immobilized on the opposite side of the DNA template inside the microfluidic chamber (figure 2).
Step 3: A Specific Surface is Catching the Expressed Protein
After cell-free expression not only our desired antigens are present within the chamber, but also all other components of the cell-free mix including ribosomes, polymerases and amino acids (figure 3). All these components would bind unspecifically to an activated glass slide, thereby obstructing the binding of the antigens. We designed our DNA constructs in a way that each antigen can easily be fused to specific tags that enable targeted immobilization on a specific surface. Testing different tag systems, we found the Ni-NTA-His-tag system to be working best for our purposes. A basic protocol for this specific surface was optimized by ourselves to reduce unspecific binding.
Step 4: The Measurement of Binding Events
After preparation of the DiaCHIP, a patient’s serum sample can be flushed over the protein array using the same microfluidic system. The binding of antibodies to the corresponding surface causes a minimal change in the thickness of the layer on the slide right at the corresponding antigen spot. This binding can be detected label-free and in real-time using a novel technique called iRIf (imaging Reflectometric Interference) without the need for further labeling. Its core components are a camera, an LED and two lenses. See how we reconstructed the system in a low-budget device.
Step 5: Changing Perspectives - Off to our Results
When illustrating the basic principle of the DiaCHIP, we mainly looked at it from the side. Now it is time to explore our results and see what we actually achieved. Therefore, it is important to have in mind that you are observing the chip from the camera's position, so basically from the top (figure 5). This persepective remains the same in all the iRIf measurements we are showing in the results section.
After weeks of optimizing the different components of the DiaCHIP, we are proud to present our results. We reached the highlight of our project with the successful detection of antibodies in our own blood!