Difference between revisions of "Team:UCLA/Notebook/Materials/9 July 2015"
Michaelc1618 (Talk | contribs) (→Michael's Part) |
|||
Line 322: | Line 322: | ||
**Considering how viscous both the silk dope and the Tamura fraction are, I should probably add some water to the mix | **Considering how viscous both the silk dope and the Tamura fraction are, I should probably add some water to the mix | ||
**Will add | **Will add | ||
+ | |||
+ | |||
+ | ==Spinning Apparatus Project== | ||
+ | *Gathered all required Materials: | ||
+ | **2 12V Stepper Motors | ||
+ | **1 Arduino Uno R3(knockoff brand) | ||
+ | **Breadboards | ||
+ | **2 Easy Driver v4.4 |
Revision as of 00:14, 10 July 2015
Michael's Part
- Continuation of yesterday's dialysis
- Dialysis STOP: 12:30 PM, July 9
- extracted about 750 uL of double dialyzed silk.
- aliquoted 20 uL of concentrated dope, allowed to dry at 60 C
- weight of empty weigh boat: 0.596 grams
- weight of weigh boat + dry silk: 0.600 grams
- calculated w/v%: 20% w/v.
- Received a fraction of Tamura from Fasih and Jessica
- We need to dilute down the silk concentrate before spinning. I do not know the concentration of the Tamura, so I will be assuming that the Tamura is dilute enough to treat as water in the calculations. That is to say, instead of diluting the silk dope with water, I will be diluting it with the Tamura fraction.
- Let's spin 250 uL of the Tamura.
- To obtain 250 uL of "15% w/v silk," we need 187.5uL of the 20% w/v silk dope, and 62.5 uL of the Tamura fraction.
- However, before adding the Tamura fraction, we need to ensure that there are no particulates
- Currently, the fraction has a lot of particulates -- probably some coagulated silk, as well as some of the resin.
- Aliquot 500 uL of the fraction into a tube. Centrifuge at 5000 RPM for 10 minutes at 4 C.
- Transfer supernatant to a syringe with a filter tip, then inject into a new tube.
- Some problems
- Upon centrifugation, both the resin and the silk particles settle at the tube bottom (checked under UV box)
- I aliquoted another 250 uL of the fraction to syringe filter, all of the silk particles were trapped in the filter (checked under UV box).
- some things we can try:
- add more solvent to try to solubilize the Tamura particulates
- I took 2 mL of "Fraction 4" from the Functionalization team
- This solution is much more viscous, has much less particulates, and has comparable fluorescent intensity when checked under the UV box.
- I will take Fraction 4 and mix it with the silk dope.
- Considering how viscous both the silk dope and the Tamura fraction are, I should probably add some water to the mix
- Will add
Spinning Apparatus Project
- Gathered all required Materials:
- 2 12V Stepper Motors
- 1 Arduino Uno R3(knockoff brand)
- Breadboards
- 2 Easy Driver v4.4