Difference between revisions of "Team:UCLA/Notebook/Materials/9 July 2015"

(Michael's Part)
Line 322: Line 322:
 
**Considering how viscous both the silk dope and the Tamura fraction are, I should probably add some water to the mix
 
**Considering how viscous both the silk dope and the Tamura fraction are, I should probably add some water to the mix
 
**Will add
 
**Will add
 +
 +
 +
==Spinning Apparatus Project==
 +
*Gathered all required Materials:
 +
**2 12V Stepper Motors
 +
**1 Arduino Uno R3(knockoff brand)
 +
**Breadboards
 +
**2 Easy Driver v4.4

Revision as of 00:14, 10 July 2015

Michael's Part

  • Continuation of yesterday's dialysis
    • Dialysis STOP: 12:30 PM, July 9
    • extracted about 750 uL of double dialyzed silk.
    • aliquoted 20 uL of concentrated dope, allowed to dry at 60 C
    • weight of empty weigh boat: 0.596 grams
    • weight of weigh boat + dry silk: 0.600 grams
    • calculated w/v%: 20% w/v.
  • Received a fraction of Tamura from Fasih and Jessica
  • We need to dilute down the silk concentrate before spinning. I do not know the concentration of the Tamura, so I will be assuming that the Tamura is dilute enough to treat as water in the calculations. That is to say, instead of diluting the silk dope with water, I will be diluting it with the Tamura fraction.
  • Let's spin 250 uL of the Tamura.
  • To obtain 250 uL of "15% w/v silk," we need 187.5uL of the 20% w/v silk dope, and 62.5 uL of the Tamura fraction.


  • However, before adding the Tamura fraction, we need to ensure that there are no particulates
    • Currently, the fraction has a lot of particulates -- probably some coagulated silk, as well as some of the resin.
    • Aliquot 500 uL of the fraction into a tube. Centrifuge at 5000 RPM for 10 minutes at 4 C.
    • Transfer supernatant to a syringe with a filter tip, then inject into a new tube.
  • Some problems
    • Upon centrifugation, both the resin and the silk particles settle at the tube bottom (checked under UV box)
    • I aliquoted another 250 uL of the fraction to syringe filter, all of the silk particles were trapped in the filter (checked under UV box).
  • some things we can try:
    • add more solvent to try to solubilize the Tamura particulates
  • I took 2 mL of "Fraction 4" from the Functionalization team
    • This solution is much more viscous, has much less particulates, and has comparable fluorescent intensity when checked under the UV box.
  • I will take Fraction 4 and mix it with the silk dope.
    • Considering how viscous both the silk dope and the Tamura fraction are, I should probably add some water to the mix
    • Will add


Spinning Apparatus Project

  • Gathered all required Materials:
    • 2 12V Stepper Motors
    • 1 Arduino Uno R3(knockoff brand)
    • Breadboards