*Position the substrate
+
*Place the glass slide and the PDMS replicas into a plasma cleaner, contact surfaces facing upwards
 +
*Exhaust the atmosphere with a vacuum pump and wait until the pressure drops to 500 mTorr
 +
*Activate the plasma for 2.5 minutes at Hi power
 +
*Stop the plasma and open the valve to stabilize the pressure, continue immediately with the bonding phase
  
 
=== Permanent irreversible bonding ===
 
=== Permanent irreversible bonding ===
  
*Place PDMS over glass slide
+
*Place the PDMS replica on the glass slide
*post-bake 80°C/1h
+
*Place the bonded device in an oven at 80°C for 60 minutes.
 +
*Seal the inlets and outlets with a scotch tape until use
  
 
= ... =
 
= ... =
  
 
{{:Team:Czech_Republic/Template:Bottom}}
 
{{:Team:Czech_Republic/Template:Bottom}}

Revision as of 14:56, 14 September 2015

Protocols

Purification

....

Restriction

...

GA

...

Soft lithography - PDMS molding

  • Silicon masters
  • 40g PDMS + 4g curing agent
  • curing 80°C/2h

Soft lithography - Bonding PDMS-Glass

Preparation of the substrates

Glass slide
  • Rinse the glass slide with acetone, isopropanol, and deionized water
  • Dry the glass slide with air gun
  • Dehydrate the glass slide on a hot plate at 120°C for 30 minutes
PDMS
  • Slice the PDMS to individual PDMS replicas
  • Drill holes for microfluidic inlets and outlets
  • Clean the PDMS using a scotch tape

Air plasma treatment

  • Place the glass slide and the PDMS replicas into a plasma cleaner, contact surfaces facing upwards
  • Exhaust the atmosphere with a vacuum pump and wait until the pressure drops to 500 mTorr
  • Activate the plasma for 2.5 minutes at Hi power
  • Stop the plasma and open the valve to stabilize the pressure, continue immediately with the bonding phase

Permanent irreversible bonding

  • Place the PDMS replica on the glass slide
  • Place the bonded device in an oven at 80°C for 60 minutes.
  • Seal the inlets and outlets with a scotch tape until use

...