Difference between revisions of "Team:Czech Republic/Protocols"
(→Band-stab PCR) |
|||
Line 10: | Line 10: | ||
= Band-stab PCR = | = Band-stab PCR = | ||
− | Excellent technique when you want to amplify specific band from a gel. | + | Excellent technique when you want to amplify specific band from a gel. [[http://bitesizebio.com/13512/pcr-rescue/ More info..]] |
* Prepare a complete 50μL PCR reaction without DNA template | * Prepare a complete 50μL PCR reaction without DNA template |
Revision as of 13:36, 16 September 2015
Protocols
Contents
Purification
....
Restriction
...
Band-stab PCR
Excellent technique when you want to amplify specific band from a gel. http://bitesizebio.com/13512/pcr-rescue/ More info..
- Prepare a complete 50μL PCR reaction without DNA template
- Take a sterile pipette tip and stab the desired band of interest 2-3 times
- Swirl the tip in the tube with prepared PCR reaction
- Run the PCR as usual
GA
...
Soft lithography - PDMS molding
- Mix 40g of PDMS with 4g of curing agent
- Centrifuge the mixture at 3250 RPM for 3 minutes to remove the bubbles introduced during the mixing
- Clean silicon master with air gun
- Wrap an aluminium foil around the edges of the silicon master to create a container
- Pour the PDMS mixture over the silicon master
- Cure the PDMS in an oven at 80°C for 2 hours
- Leave the PDMS to cool down
- Detach the PDMS carefully from the silicon master
Soft lithography - Bonding PDMS-Glass
Preparation of the substrates
Glass slide
- Rinse the glass slide with acetone, isopropanol, and deionized water
- Dry the glass slide with air gun
- Dehydrate the glass slide on a hot plate at 120°C for 30 minutes
PDMS
- Slice the PDMS to individual PDMS replicas
- Drill holes for microfluidic inlets and outlets
- Clean the PDMS using a scotch tape
Air plasma treatment
- Place the glass slide and the PDMS replicas into a plasma cleaner, contact surfaces facing upwards
- Exhaust the atmosphere with a vacuum pump and wait until the pressure drops to 500 mTorr
- Activate the plasma for 2.5 minutes at Hi power
- Stop the plasma and open the valve to stabilize the pressure, continue immediately with the bonding phase
Permanent irreversible bonding
- Place the PDMS replica on the glass slide
- Place the bonded device in an oven at 80°C for 60 minutes.
- Seal the inlets and outlets with a scotch tape until use
...