Difference between revisions of "Team:Aachen/Lab/Bioreactor/Characterization of Bioreactor"
Line 17: | Line 17: | ||
{{Team:Aachen/Figure|Aachen_Reactor1ODvsD.png|size=large|title = Plot of Optical Density versus Dilution|subtitle =Chemostat growth of in medium M9}} | {{Team:Aachen/Figure|Aachen_Reactor1ODvsD.png|size=large|title = Plot of Optical Density versus Dilution|subtitle =Chemostat growth of in medium M9}} | ||
The Batch mode ran for 5 hours until we observed OD above the threshold of 1.0 in the reactor to start increasing the dilution rate. | The Batch mode ran for 5 hours until we observed OD above the threshold of 1.0 in the reactor to start increasing the dilution rate. | ||
+ | |||
The continuous mode was started with dilution rate of 0.1 /h at hour 5. Constant OD was obtained for 9 hours but soon it was observed that the feed pump was supplying more medium than the harvest removed by the harvest pump. At hour 30, we decided to modify the Master COntrol Program to change the speed of the harvest pump. Therefore, the harvest pump rate was changed to pump 30% faster than the feed pump. This can be observed in the reduction in the OD from an average of 0.78 to 0.76. | The continuous mode was started with dilution rate of 0.1 /h at hour 5. Constant OD was obtained for 9 hours but soon it was observed that the feed pump was supplying more medium than the harvest removed by the harvest pump. At hour 30, we decided to modify the Master COntrol Program to change the speed of the harvest pump. Therefore, the harvest pump rate was changed to pump 30% faster than the feed pump. This can be observed in the reduction in the OD from an average of 0.78 to 0.76. | ||
+ | |||
At hour 48, the dilution rate was changed, for step 2 of the experiment, to 0.3 /h. The OD was observed to be stable with few variations within pipetting error. | At hour 48, the dilution rate was changed, for step 2 of the experiment, to 0.3 /h. The OD was observed to be stable with few variations within pipetting error. | ||
+ | |||
The step 3 was carried out at hour 63, with dilution rate at 0.4 /h. This resulted in OD values for 3 reactor volumes, which lasted for 7.5 hours. | The step 3 was carried out at hour 63, with dilution rate at 0.4 /h. This resulted in OD values for 3 reactor volumes, which lasted for 7.5 hours. | ||
Revision as of 20:16, 18 September 2015