Difference between revisions of "Team:Paris Bettencourt/Practices/DILambda"
(2 intermediate revisions by the same user not shown) | |||
Line 18: | Line 18: | ||
<div class="column-right"> | <div class="column-right"> | ||
− | <video width="100%" height="360" controls preload=" | + | <video width="100%" height="360" controls preload="metadata"> |
<!-- MP4 must be first for iPad! --> | <!-- MP4 must be first for iPad! --> | ||
<source src="https://static.igem.org/mediawiki/2015/1/1a/ParisBettencourt_JuanmaMovie.mp4" type="video/mp4" /><!-- WebKit video --> | <source src="https://static.igem.org/mediawiki/2015/1/1a/ParisBettencourt_JuanmaMovie.mp4" type="video/mp4" /><!-- WebKit video --> | ||
Line 119: | Line 119: | ||
<p> | <p> | ||
All this means that DI-lambda is not always able to replace a traditional spectrophotometer, but works great for a majority of biological applications.</p> | All this means that DI-lambda is not always able to replace a traditional spectrophotometer, but works great for a majority of biological applications.</p> | ||
+ | |||
+ | The design files are available on Github: https://github.com/lopenlab/OSS-Spectrophotometer/ | ||
</div> | </div> | ||
Line 127: | Line 129: | ||
<div style="clear: both"></div> | <div style="clear: both"></div> | ||
+ | <h2>Accuracy</h2> | ||
+ | |||
+ | <div class="column-left"> | ||
+ | <p> | ||
+ | We put a lot of time into calibrating our spectrophotometer. After tuning parameters, such as the distance between the LED, the sensor, and the cuvette, and the diameter of the pinhole through which the light has to pass, we achieve results that are virtually identical to our most reliable laboratory spectrophotometer. | ||
+ | </p> | ||
+ | </div> | ||
+ | |||
+ | <div class="column-right"> | ||
+ | <img src="https://static.igem.org/mediawiki/2015/4/4c/DI-Lambda_comparision.png" style="width: 100%"> | ||
+ | <p class="caption"><b>Figure 6:</b>Comparision between DI-Lambda and UVline 9100</p> | ||
+ | </div> | ||
+ | <div style="clear: both"></div> | ||
<h2>Workshops</h2> | <h2>Workshops</h2> | ||
Line 138: | Line 153: | ||
<div class="column-right"> | <div class="column-right"> | ||
<img src="https://static.igem.org/mediawiki/2015/7/7e/ParisBettencourt_juanma03.jpg" style="width: 100%"> | <img src="https://static.igem.org/mediawiki/2015/7/7e/ParisBettencourt_juanma03.jpg" style="width: 100%"> | ||
− | <p class="caption"><B>Figure | + | <p class="caption"><B>Figure 7:</b> DI-lambda Luna. It is a version designed specifically for our workshop at the NightScience 2015 conference held at the Center for Research and Interdisciplinarity in Paris. Largely based on the test rig model, with some added elegance. It is easy to build, and can be used for Do-It-yourself workshops. Search on github to get the complete design! External links are not permitted on wiki.</p> |
</div> | </div> | ||
<div style="clear: both"></div> | <div style="clear: both"></div> | ||
Line 153: | Line 168: | ||
<div class="column-right"> | <div class="column-right"> | ||
<img src="https://static.igem.org/mediawiki/2015/0/08/ParisBettencourt_juanma09.jpg" style="width: 100%"> | <img src="https://static.igem.org/mediawiki/2015/0/08/ParisBettencourt_juanma09.jpg" style="width: 100%"> | ||
− | <p class="caption"><p>Figure | + | <p class="caption"><p>Figure 8:</b> DI-lambda spectrophotometers built in a workshop with UCL, Birkbeck and London Hackerspace iGEM teams organized by UCL.</p> |
</div> | </div> | ||
<div style="clear: both"></div> | <div style="clear: both"></div> |
Latest revision as of 03:59, 19 September 2015