<h4> Results:</h4> | <h4> Results:</h4> | ||
+ | <p>Earlier testing using the standard set-up (single LED illumination, GFP epi-cube) indicated that visualising fluorescent beads was possible with OpenScope (Fig. 1). </p> | ||
+ | |||
<p>Testing using the commercial fluorescence microscope confirmed that the samples had phenotypes as reported by William and Mary. Both constructs resulted in GFP expression in E. coli. J23106+I13504 demonstrated increased fluorescence intensity relative to J23117+I13504.</p> | <p>Testing using the commercial fluorescence microscope confirmed that the samples had phenotypes as reported by William and Mary. Both constructs resulted in GFP expression in E. coli. J23106+I13504 demonstrated increased fluorescence intensity relative to J23117+I13504.</p> | ||
− | <p> A control slide (sample taken from the agar of the control plate, untransformed cells plated on Amp) was first tested to establish a fluorescence-free baseline (Fig. | + | <p> A control slide (sample taken from the agar of the control plate, untransformed cells plated on Amp) was first tested to establish a fluorescence-free baseline (Fig. 2a). The duplicate J23106+I13504 samples were then tested using the standard set-up (100mW LED) and non-standard set-up (3W LED). Fluorescence was detected (Fig. 2b and 2c).</p> |
<div style="float:left; margin-right: 20px"><img src="https://static.igem.org/mediawiki/2015/9/94/CamJIC-W%26MControl.png" style="height: 200px"></div> | <div style="float:left; margin-right: 20px"><img src="https://static.igem.org/mediawiki/2015/9/94/CamJIC-W%26MControl.png" style="height: 200px"></div> | ||
Line 84: | Line 86: | ||
<h4> Results:</h4> | <h4> Results:</h4> | ||
<p>After preliminary testing using the RFP epi-cube, it was decided that imaging of RFP at this stage would not be possible. Hence only bacterial strains expressing GFP (as confirmed earlier) were tested against the control.</p> | <p>After preliminary testing using the RFP epi-cube, it was decided that imaging of RFP at this stage would not be possible. Hence only bacterial strains expressing GFP (as confirmed earlier) were tested against the control.</p> | ||
− | |||
<p>Testing using the commercial fluorescence microscope confirmed that the samples had phenotypes as reported by Glasgow. From tube 5, a small proportion of the cells were expressing RFP and the majority expressed GFP as predicted.</p> | <p>Testing using the commercial fluorescence microscope confirmed that the samples had phenotypes as reported by Glasgow. From tube 5, a small proportion of the cells were expressing RFP and the majority expressed GFP as predicted.</p> | ||
− | <p>Results from preliminary testing of DH5α cells with p126.1 and p56.1 (confirmed: GFP expression only) using the standard set-up indicated illumination brightness was insufficient to detect GFP. The non-standard set-up was used, and GFP expression was confirmed in p126.1, p126.+p56.1 and p126.1+p80.1 cells as expected (Fig. | + | <p>Results from preliminary testing of DH5α cells with p126.1 and p56.1 (confirmed: GFP expression only) using the standard set-up indicated illumination brightness was insufficient to detect GFP. The non-standard set-up was used, and GFP expression was confirmed in p126.1, p126.+p56.1 and p126.1+p80.1 cells as expected (Fig. 3a-d). The images display an artefact of the square shape of the LED used, as there is an area of increased fluorescence in the outline of a square at the centre of the images (Fig 3c and d). </p> |
<div style="float:left; margin-right: 20px"><img src="https://static.igem.org/mediawiki/2015/f/f0/CamJIC-GlasgowControl.png" style="height: 175px"></div> | <div style="float:left; margin-right: 20px"><img src="https://static.igem.org/mediawiki/2015/f/f0/CamJIC-GlasgowControl.png" style="height: 175px"></div> | ||
Line 92: | Line 93: | ||
<div style="float:left; margin-right: 20px"><img src="https://static.igem.org/mediawiki/2015/4/4f/CamJIC-Glasgowp126.1p80.1.png" style="height: 175px"></div> | <div style="float:left; margin-right: 20px"><img src="https://static.igem.org/mediawiki/2015/4/4f/CamJIC-Glasgowp126.1p80.1.png" style="height: 175px"></div> | ||
<div style="float:left; margin-right: 20px"><img src="https://static.igem.org/mediawiki/2015/a/a9/CamJIC-Glasgowp126.1p56.1.png" style="height: 175px"></div> | <div style="float:left; margin-right: 20px"><img src="https://static.igem.org/mediawiki/2015/a/a9/CamJIC-Glasgowp126.1p56.1.png" style="height: 175px"></div> | ||
− | <div style="float:left; margin-right: 20px"><p><i><b>Fig. | + | <div style="float:left; margin-right: 20px"><p><i><b>Fig. 3:</b> <b>a</b> Control slide (left) showing no fluorescence <b>b</b> p126.1 samples imaged using non-standard set-up under 470nm excitation (centre left)<b>c</b> p126.1+p80.1 samples imaged using non-standard set-up showing fluorescence (centre right) <b>d</b>p126.1+p56.1 samples imaged using non-standard set-up (right). All images were captured using the Webshell on 15.09.15 and are unedited.</i></p></div> |